My ExportersIndia

For Buyer

For Seller

For Help

Our Products

We offer the best product range of Ultra Low Maintenance Batteries, Single -Phase Inverter and 3 - Phase Inverters.

3 - Phase Inverters

  •   Model    UNIQUE
  •    Rating    3KVA to 50KVA
  •    Technology    IGBT, Micro Controller Based, High Frequency
  •    Input Voltage    Window 415V + 10 % - 15 %, 47 -52Hz 
  •    Output Voltage    400V + / - 1%
  •    Output Frequency    50Hz + / - 0.5 %
  •    Output Waveform    PWM Pure Sine Wave
  •    Inverter Efficiency    >85 - 92% depending on DC voltage
  •    Acoustic Noise    >45Db at 1 meter
  •    Audible alaram    Mains Failure, Battery Low, Battery Low Trip
  •    Battery Voltage    120VDC to 360 VDC depending on model
  •    Backup Time    1 Hour to 10 Hours At full load.
  •    Type of Batteries    Pested Plates / Tubular / Sealed Maintenance Free
  •    Recharging time    10 Hrs. for 90% Capacity
  •    Protections    OUTPUT :- Over Voltage, Under Voltage, Over Load, Short Circuit    BATTERY :-Over Charging, Low Battery

The power backup system is essentially meant for the lifts installed in multi stored buildings, offices, Mfg. Plants, Shopping Malls, Etc. This system ensures that the above applications continue to operate as if nothing happened even after the electricity failure. One doesnt need to rush to start the generators. the system is always alert and has the intelligence to sense power failure. This user friendly systems are compact in size and are tailor made to particular sites.

Power Backup System:

LIFTS, Shopping Malls Lightings, Air conditioners, Process Industries, 3 Motors, Pumps.

The Power Backup System is essentially meant for the Lifts installed in multi stored buildings, Offices, Mfg. Plant, Shopping Malls, Etc. This system ensures that the above applications continues to operate as if nothing happened even after the electricity failure. One doesnt need to rush to start the generators. The system is always alert and has the intelligence to sense Power Failure. This user friendly System is compact in size and are tailor made to particular sites

System Operation :

In the normal condition when the electricity is available, the LIFT ( Application ) is directly connected to the Main power and small portion of the Mains supply is used in charging the storage batteries. In the event of electricity failure the system instantaneously senses it and generates AC Power from the batteries. All theses activities are carried out with few seconds thus ensuring that the Applications remains without power only for few seconds. When the Main supply resumes the Applications are automatically switched over to it and a small portion of it is again utilized for charging of the batteries. This cycle is repeated again during the next power failure.

These Systems are available in various models and different capacities to suite all available Lifts & Other Various Capacities of Applications. The System is specially designed unit. The battery bank has the capacity to take care of power failure for fairly long time upto 8 to 10 hrs. The common lighting load such as Staircase, Parking an also be connected on the same system. In case of a multi building complex options can be considered for providing single unit for number of lifts etc. on prior site checking for Lift Application.

View Complete Details

Single -Phase Inverter

Pure Sine Wave Inverter:

Our Power supply is your total valuable solution of electric for small and home users.We are professional manufacturer and designer if Inverter and other power products,

NC Inverter series is a new milestone in the field of pure sine wave inverter.

Our technical advantages are as follows:

1) Completely controlled by CPU. These inverters are capable of driving highly reactive & capacitive loads at start up. Synchronized operation allows the transfer to be almost instantaneous.

Fast Automatic switching for continues power supply within 4 ms. When the Ac comesIt will start immediately; and when its over load, it will also lock itself at once, when you reduce the load, then it will start working automatically. For example, you dont need to restart you PC while using it with its integrated UPS Function.

2) Short circuit Protection and Overload protection. Wide input voltage: 90 V --- 280V.

3) Chargeing function is storng, quick and stable ; the average recharging current is 10 A Mps. ( But we can make it larger, It is up to customers requirements)

4) Pure sine wave output; 220V+3%(THD

Model NC600 NC800 NC1000 NC1500 NC2000 NC2500
Capacity 600VA 800VA 1000VA 1500VA 2000VA 2500VA
    420W 560W 700W 1050W 1400W 1750W
  Voltage range                                          110V - 280V AC
Input Frequency range                                          50Hz ± 5Hz 
  AVR                Four Steps AVR,                   220V ± 10%
Output Inversion Voltage                220V ± 3%
  Inversion Frequency                50HZ ± 2%
           DC Voltage 12V 24V 48V
           O/P Waveform                                 sine wave
           THD                                 ≤3%
           Transfer time                 ≤ 4ms Automatic Transfer
           Recharge Current                 10-15 A                           15A - 25A
           Transfer Efficiency                 85%                         90-96%
           Protections                 Protection against Short-circuit, Overload
           Communication Ports                 RS 232
           Unit Size (mm)                                         372*122*195    397*145*215     460*192*335
N.W (KG) 6.8  7.8  10.8  12  20.5   23.5 
K.W (KG) 7.8  9.4  12.3 13.5  22.5  25.5 
Shipping Size (mm) 385*442*303 400*293*218 570*297*442
  2Pcs 2Pcs 1Pcs
 
Model NC3000 NC5000 NC6000 NC8000 NC10000 NC15000
Capacity 3KVA 5KVA 6KVA 8KVA 10KVA 15KVA
  2.1KW 3.5KW 4.2KW 4.48KW 7KW 10.5KW
  Voltage range                                          110V - 280v AC                              175 - 265 VAC
Input Frequency range                                          50Hz ± 5Hz 
  AVR                Four Steps AVR, 220V ± 10%                  Without 220V ± 10%
Output Inversion Voltage                220V ± 3%
  Inversion Frequency                50HZ ± 2%
           DC Voltage 48V 96V 240V
           O/P Waveform                                 sine wave
           THD                                  ≤ 3%
           Transfer time                 ≤ 4ms Automatic Transfer
           Recharge Current                 15A-25 A     10A
           Transfer Efficiency                                  90 - 96%
           Protections                 Protection against Short-circuit, Overload
           Communication Ports                 RS 232
           Unit Size (mm)                460*192*335                      555*360*720
N.W (KG) 29.3  34.2  38.5  56.5  78.5   108.5 
K.W (KG) 31.5  36.5  40.5 60.7  82.8  112.8 
Shipping Size (mm) 570*297*442
View Complete Details

Ultra Low Maintenance Batteries

  • Filling Gravity 1.230 0.005 @ 27°C
  • Rest Period 12
  • hours Charging Current 0.10C Amps
  • Charging Duration 48 hours (MINIMUM)
  • Final Gravity 1.240 ~1.250 @ 27°C

Our Tubular Ultra Low Maintenance Battery is made using the special technology by which the active material is encapsulated in polyester tubes to prevent 'Shedding'. The electrode geometry facilities 'cyclic' deep discharges i.e. long repetitive power outages. They are recommended for back up power for UPS & Inverters where environmental conditions are tough and high ambient temperatures are common. Tubat Tobular proved to be most reliable source of back up power for Inverters and UPS operating under demanding conditions. These are capable of long hours of backup.

Applications - Stored Power For

  • UPS [Un-Interrupted Power Supply
  • Communication Equipments
  • Solar Power Systems
  • Lighting
  • Domestic
  • Industrial
  • Inverter
  • Wind Mills
  • And Other Stationery Applications

Salient Features

  • Steady Output
  • Aquatrap Ventplug Ensures
  • Low Maintenance
  • No Acid Fumes
  • Eco Friendly
  • Low Antimony Allow
  • Large Top-Of-Plate Acid Head Room
  • Quick Recovery From Deep Discharge
  • Extra Backup Time

Technical Specifications : Tubular Regular Series (Voltage (C10)- Size - mm (LxWxH) 5mm)

  • 12V 120 AH - 440x185x415
  • 12V 150 AH - 440x185x415
  • 12V 180 AH - 440x185x415
  • 12V 200 AH - 440x185x415
  • 12V 220 AH - 440x185x415
  • 12V 240 AH - 440x185x415

Initial Charging Instructions

  • Filling Gravity: 1.230 0.005 @ 27C
  • Rest Period : 12
  • hours Charging Current: 0.10C Amps
  • Charging Duration: 48 hours (MINIMUM)
  • Final Gravity : 1.240 1.250 @ 27C

Normal Charging Instructions

  • (After a capacity discharge) Normal charging rate: 0.1 OC Amps Condition for fully charged state: (For both a & b)
  • Charge till constancy in voltage and specify gravity reading for 3 consecutive hours and free gassing in all the cells

Maintenance Instructions

  • Recharge battery after prolonged use. Keep battery top and terminal clean & dry Ensure good ventilation in the room
  • Toping with distilled water 2 to 3 times a year Wooden or plastic (No conductivity) planks should be used for placing the battery
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us