ATS has developed a new programmable control which is activated by a magnet passing a sensor mounted on equipment close to magnets path. A signal is sent to the circuit board in the lubricator which maintains the lubricators dispense cycle. A BLUE LED will flash every time the magnet passes the sensor. This indicates that the magnetic sensor is working. If the equipment is inactive, the lubricator will time out and go into suspense mode until the equipment is again active. The lubrication cycle will then resume, as though the equipment had never shut down. The Motion activated control (MC) is an alternative to the Remote Control (RC). The lubricators DIP Switches are selected, as described on the lubricators Installation Instructions, according to the volume of the lubricant desired during the equipments actual operating cycle.