We offer a complete product range of WG MMPB 3 Solid State Relay, WG A0 Solid State Relay, WG A3 Solid State Relay, WG MMPB 2 Solid State Relay and WG (M)OAC Solid State Relay
Maxi Puck Housing, Panel Mounted AC Loads, DC Input, Motor ReversingThis series is recommended for electronic motor reversing in three phase systems. Load voltages up to 480 Vac and load currents up to 45 A can be switched. A built-in interlocking circuit with a typical change over switching time 60 +-20ms prevents simultaneous switching-on of forward and reverse functions and prevents a short circuit between two phases. A LED indicates the forward and reverse function.
Maxi Puck Housing, Panel Mounted AC Loads, DC Input, 3 Phase This series is able to switch three phase loads with one control signal up to rated line currents of 45A and line voltages up to 480Vac. The WG A3 has high noise immunity and an internal overvoltage protection which becomes effective at 1000 V.
Output ModulesSwitching: Zero CrossInput: DC (input resistance) 250 Ohms 1000 Ohms 2000 OhmsOutput: TriacApplication: Resistive loads and inductive loads with cos > 0, 85
Hockey Puck Housing, Panel Mounted AC Loads, AC Input, Thyristor 280V Designed to switch inductive loads like electric motors and valves (R-types) as well as resistive loads like heaters and lamps (Z-type).
Hockey Puck Housing, Panel Mounted AC Loads, AC Input, Thyristor 280V Designed to switch inductive loads like electric motors and valves (R-types) as well as resistive loads like heaters and lamps (Z-type).
Hockey Puck Housing, Panel Mounted AC Loads, DC Input, BTB Thyristor 280V Designed to switch inductive loads like electric motors and valves (R-types) as well as resistive loads like heaters and lamps (Z-type).
Hockey Puck Housing, Panel Mounted AC Loads, DC Input, BTB Thyristor 480V For switching applications in three phase systems, the WG 480 series offers excellent reliability due to high noise immunity (maximum peak-off-state voltage of 12001600V) and extremely good dvdt characteristics (partly with integrated overvoltage protection).
Hockey Puck Housing, Panel Mounted AC Loads, DC Input, BTB Thyristor 660V For switching applications in three phase systems, the WG 660 series offers excellent reliability due to high noise immunity (maximum peak-off-state voltage of 12001600V) and extremely good dvdt characteristics (partly with integrated overvoltage protection).
Boards, interface modules, 1 to 8 relays the module boards are supplied without solid state relays or miniature fuses. The fuses are easy to change and there is led status identification. Screw less mounting with mini-modules.
Boards, ac loads, motor reversing the module boards are supplied without solid state relays or miniature fuses. The fuses are easy to change and there is led status identification. Screw less mounting with mini-modules.
PCB Mounting, AC Loads, 3 to 5A280V Especially developed for PCB mounting with very small dimensions and load currents of 3A or 5A. There are types with 600 V peak-off-state voltage as well as types with 1200 V available. The WG A5 is available in zero cross switching (Z-types) for resistive and capacitive loads or in random switching (R-types) for inductive loads.
PCB Mounting, AC Loads, 5A420 to 660V Especially developed for PCB mounting with very small dimensions and load currents of 3A or 5A. THere are types with 600 V peak-off-state voltage as well as types with 1200 V available. The WG A5 is available in zero cross switching (Z-types) for resistive and capacitive loads or in random switching (R-types) for inductive loads.
Pcb mounted, dc loads, 50 to 400v this pcb mounting type has a mosfet output, suitable for resistive and capacitive loads. For inductive loads a protection circuit (diode or snubber) is recommended.
Panel mounted, dc loads, mosfet 50 to 400v this is the chassis mounting version with mosfet output and load currents up to 30a. Types with igbt output are available for high load voltages.
Hockey Puck Housing, Panel Mounted, Special SSR, Monitoring Microprocessor controlled monitoring relay with LED-indication of the status and alarm output. Indicates open or short circuit, interruption, supply voltage and AC line voltage loss.