Industrial Water Filters
2 Products availablePackaged Drinking Water Plant
2 Products availableWe offer the best product range of Industrial Water Softening Plant, 2000 LPH Industrial RO Plant, 1000 LPH Commercial RO Plant, 3000 LPH Industrial RO Plant and 4000 LPH Industrial RO Plant.
Our industrial water softening plants are the biggest plants we have and are mostly used for factories or similar buildings and businesses. These industrial plants cover much more space than the other two softening plants we offer and they also soften more water at the same time without having the trouble of breaking down or cutting the process in the half. You can soften much more water with these plants and use it for anything you want, either for production or for your workers. However, depending on the size of your industry, you need to get a quote on your price and also on the size of the plant.
Process :Raw Water Pump? Sand Filter ? Carbon Filter ? Anti Scalent Dosing System ? Micro Filtration? High Pressure Pump ? Membrane
In case of high Turbidity customer needs to provide a settlement tank and Alum dosing system is to be incorporated. The cost of the same has not been considered with in the scheme.
Technical Specification :Raw Water Tank (Client Scope)
This tank ensures a constant supply of the raw water to the machine.
Feed Water PumpThe system would require an Inlet Pressure of 2 Kg/cm2 minimum for smooth operation. To provide the same the Raw Water Pump is being incorporated in the system.
Description :
Pressure Sand FilterThe system is required to be feed with 0 turbidity water. The Pressure Sand Filter is incorporated in the system to ensure the same. The Pressure Sand Filter offers a filtration up to 30 microns.
The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5 Kgs/cm2, Multi Graded Sand Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the sand filter.
The filter is designed for 14m/sec internal flow for proper filtration.
Description:
Activated Carbon FilterThis system is required to be feed with NIL Chlorine water. The Activated Carbon Filter is incorporated in the system to ensure the same. It also ensures that the water is color less, odor less and contains no dissolved gases.
The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5Kgs/cm2, Multi Graded Sand and Activated Carbon Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the Activated Carbon filter.
The filter is designed for 14 m/sec internal flow for proper filtration.
Description:
Anti Scalent Dosing SystemThe ANTI SCALENT DOSING SYSTEM gives the system an extra protection towards any kind of scale formation over the membranes. Chemicals are chosen depending on the water analysis report of the raw water. These chemicals are dosed in the water inflow drop by drop. The chemicals agitate the dissolved particles in the water so as not to allow them to settle down on the membrane surface.
Description:
Micron Filter :Due to the induction of the Dosing Chemical some of the particles may coagulate in the water. This coagulated particals cannot be allowed to enter the membrane. The Micron Filter ensures that all such particles above the size of 5 Micron are being filtered out of the water so as to enhance the system life. It also ensures that even all undissolved particles above the size of 5 Micron are being filtered out.
Description:
High Pressure Pump :In the system, the membrane filtration takes place at high pressure only in the range of 8-14 KG/CM2. To provide such high pressure the Pressure Booster Pump is being induced in the system to boost the pressure to the required level for the proper filtration process.
Description:
Membrane Housing :The membrane housing provides the shell for the membranes to allow the highly pressurized water to pass through the membrane.
Description:
Membrane :The system consists of Thin Film Composite Membrane made out of Poly Urethane acetate that provides a filtration level up to 0.0001 micron. These operate at a pressure between 9-14 KGS/CM2 this result in a dissolved salt rejection of upto 98%. The membrane separates the water into two streams. One is the premed or the product water and the other is the rejection.
Description:
Accessories
Wet Panel :
Piping :
Process :Raw Water Pump? Sand Filter ? Carbon Filter ? Anti Scalent Dosing System ? Micro Filtration? High Pressure Pump ? Membrane
In case of high Turbidity customer needs to provide a settlement tank and Alum dosing system is to be incorporated. The cost of the same has not been considered with in the scheme.
Technical Specification :
Raw Water Tank (Client Scope)
This tank ensures a constant supply of the raw water to the machine.
Feed Water PumpThe system would require an Inlet Pressure of 1.5 Kg/cm2 minimum for smooth operation. To provide the same the Raw Water Pump is being incorporated in the system.
Description :
Pressure Sand FilterThe system is required to be feed with 0 turbidity water. The Pressure Sand Filter is incorporated in the system to ensure the same. The Pressure Sand Filter offers a filtration up to 30 microns.
The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5 Kgs/cm2, Multi Graded Sand Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the sand filter.
The filter is designed for 14m/sec internal flow for proper filtration.
Description:
Activated Carbon FilterThis system is required to be feed with NIL Chlorine water. The Activated Carbon Filter is incorporated in the system to ensure the same. It also ensures that the water is color less, odor less and contains no dissolved gases.
The Filter consists of a Non Corrosive Vessel that can withstand pressure up to 6.5 Kgs/cm2, Multi Graded Sand and Activated Carbon Filtration Media for filtration, Internal Distribution System to distribute the water evenly inside the vessel for proper filtration, Multi Port Value (MPV) for easier operation along with Back Wash and Rinse facilities, a stand to hold the MPV in position and Pressure Gauges to know the position of the Activated Carbon filter.
The filter is designed for 14 m/sec internal flow for proper filtration.
Description:
Anti Scalent Dosing SystemThe ANTI SCALENT DOSING SYSTEM gives the system an extra protection towards any kind of scale formation over the membranes. Chemicals are chosen depending on the water analysis report of the raw water. These chemicals are dosed in the water inflow drop by drop. The chemicals agitate the dissolved particles in the water so as not to allow them to settle down on the membrane surface.
Description:
Micron Filter :Due to the induction of the Dosing Chemical some of the particles may coagulate in the water. This coagulated particals cannot be allowed to enter the membrane. The Micron Filter ensures that all such particles above the size of 5 Micron are being filtered out of the water so as to enhance the system life. It also ensures that even all undissolved particles above the size of 5 Micron are being filtered out.
Description:
High Pressure Pump :In the system, the membrane filtration takes place at high pressure only in the range of 8-14 KG/CM2. To provide such high pressure the Pressure Booster Pump is being induced in the system to boost the pressure to the required level for the proper filtration process.
Description:
Membrane Housing :The membrane housing provides the shell for the membranes to allow the highly pressurized water to pass through the membrane.
Description:
Membrane :The system consists of Thin Film Composite Membrane made out of Poly Urethane acetate that provides a filtration level upto 0.0001 micron. These operate at a pressure between 9-14 KGS/CM2 this result in a dissolved salt rejection of upto 95%. The membrane separates the water into two streams. One is the premed or the product water and the other is the rejection.
Description:
Accessories
Wet Panel :
Piping :
flow rate :
raw water pump
purposeto feed the dual media filter at pressure more than 2.0 bar, which is min. operating pressure for filter.
specifications
dual media filter
purposeto remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes
specifications
vessel :
valve :
media :mixed bed sand media consisting of the followingi) gravel ii) pebbles iii) quartz sand iv) anthraciteaverage porosity 50 micron particulate sizebed depth : 600 mm
pipelines & accessories:pipe of pvc 10 bar tested pressure
activated carbon filter
purposeto remove the total color, smell, odor, from the water.
specifications
vessel:
valve:
media:mixed bed sand media consisting of the followingi) gravel ii) pebbles iii) carbonaverage porosity 50 micron particulate sizebed depth: 600 mm
pipelines & accessories:pipe of pvc 10 bar tested pressure
dosing system :
purposeto dose antiscalant chemical to protect the scaling formation on ro membranes.
specifications
micron filter :
purposeto remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level.
specifications
cartridge filter & housing
housing :make: flowtec
cartridge :
high pressure pump :
purposeto feed the reverse osmosis membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.
specificationsmoc : stainless steel
ro membrane
purposeto remove the major part of tds upto 98% by reverse osmosis membranes arranged and designed to give adequate flow and recovery.
specifications
ro pressure tube
purposeto pack reverse osmosis membranes and operate at high pressure up to 300 psi
specifications
electrical panel :
purposea control panel is provided as a safety measure for the pumps & other electrical items.
specifications
instrumentation :
purpose
specifications
rota meter :
pressure switch :
pressure gauges :