We offer a complete product range of Dual power supply (LV-30 B/2), E.H.T Power Supply ( HV-20), Regulated power supply (D-12), Solid state power supply (LV- 30/1) and Solid State power supply (LV- 30/5)

Solid State Power Supply (LV- 30/1)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Power Supply
  • Condition New
  • Feature Proper Working
  • Total Carbohydrate 1yr
  • LINE REGULATIONS Better than +_0.05% for +_ 10% changes in mains.
  • LOAD REGULATION Better than +_ 0.05% from No load to full load
  • RIPPLES Less than 1 mVolt rms at full load
  • PRODUCTION Protected against overloading and short circuiting
  • METERS Digital Meters fitted to read output voltage and current
  • INTERNAL RESISTANCE <= 15, m ohm
  • STABILITY <= 2.5, m Volt
  • RECOVERY TIME <=80 μS.
  • TEMP. COEFFICIENT <= 0.05% + 5, mVolt/ 0 C
  • SETTING RESOLUTION : VOLTAGE Approx. 10mVolt.
  • CURRENT Approx. 2 mAmp
  • INSULATION Between chassis output terminals < 10, m ohm. at 100, Volts D.C. Between chassis AC Plug. < 50, M ohm. at 500, Volts D.C
  • POWER SUPPLY 230 Volt 10%, 50 Hz.
  • NOTE THESE ARE ALSO AVAILABLE IN DUAL UNITS

0 - 30 Volt at 1 Amp ,

There may be any change in specification due to continuous R & D without notice.

Additional Information:

Delivery Time : Depends on location

View Complete Details

Solid State Power Supply (LV- 30/5)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Condition New
  • Feature EXCELLENT STABILITY
  • Total Carbohydrate 1yr
  • LINE REGULATION Better than +_0.05% for +_10% changes in mains.
  • LOAD REGULATION Better than +_0.05% from No load to full load
  • RIPPLES Less than 1, mVolt rms at full load.
  • PROTECTION Protected against overloading and short circuiting
  • METERS Digital Meters fitted to read output voltage and current.
  • INTERNAL RESISTANCE <= 15, m ohm.
  • STABILITY <= 2.5, m Volt
  • SETTING RESOLUTION : VOLTAGE App. 10, mVolt.
  • CURRENT App. 2, mAmp.
  • INSULATION Between chassis output terminals. < 10, m ohm. at 100, Volts D.C. Between chassis AC Plug. < 50, M ohm. at 500, Volts D.C.
  • POWER SUPPLY 230, Volt 10%, 50 Hz.

0 - 30 Volt at 5 Amp (LV-30/5)

By investing considerable amount and skilled labour we have developed these Power Supplies with unbeatable performance and capacity. We offer a wide range of Solid State Power Supplies at very competitive prices. The latest designs and technology are used. These power supplies exhibit extremely high level of reliability.

Additional Information:

Delivery Time : Depends on location

View Complete Details

Solid State Power Supply (LV-05)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Condition New
  • Feature Proper Working, Superior Finish
  • Total Carbohydrate 1yr
  • OUTPUT 0 – 5, Volt.
  • CURRENT 0 – 10, Amp.
  • LINE REGULATION Better than 0.05% for +_10% changes in mains.
  • LOAD REGULATION Better than +_ 0.05% from No load to full load.
  • RIPPLES Less than 1, mVolt rms at full load.
  • PROTECTION Protected against overloading and short circuiting
  • METER Digital Meter fitted to read output voltage and current.
  • POWER SUPPLY 230, Volt 10%, 50 Hz.

output: 0 - 1500 Volts at 0 - 1 Amp ( LV- 05) ,

There may be any change in specification due to continuous R & D without notice

Additional Information:

Payment Terms : L/C, T/T,

Delivery Time : Depends on location

View Complete Details

E.H.T Power Supply ( HV-20)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Condition New
  • Feature Proper Working, Superior Finish
  • Total Carbohydrate 1yr
  • INPUT VOLTAGE 230, Volt, ± 10%, 50 Hz.
  • OUTPUT 0 – 1500 Volts D.C. (Adjustable).
  • POLARITY +ve or –ve (as required)
  • MAXIMUM CURRENT 1, mAmp
  • REGULATION Better than + 0.02% for + 10% change in mains voltage.
  • RIPPLE Approx. : 5, mVolt.
  • METERING A Linear Scale Moving Coil Panel Meter graduated In 100 divisions.
  • PROTECTION The unit is fully protected against overloading and Short – circuiting by current limiting arrangement.
  • ON DEMAND EXTRA Digital Display can be provided to read output voltage at extra cost.

output : 0 - 1500 Volts at 1mAmp (HV- 20),

An all solid state circuit, with latest I.C.s and other components, the output is adjustable with 1, volt step with 10, turn potentiometer.Output can be used with both polarities, I.C. +ve or ve, as desired, the power supply is fully protected against overload and short circuiting.

Additional Information:

Payment Terms : L/C, T/T,

Delivery Time : Depends on location

View Complete Details

Regulated Power Supply (D-12)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Condition New
  • Feature Easy To Install, Proper Working, Superior Finish, ** EXCELLENT STABILITY. ** ADJUSTABLE OUTPUT. ** COMPACT IN SIZE. ** PROTECTED AGAINST OVER LOADING
  • Total Carbohydrate 1yr
  • Output Voltage + 12 Volt, – 12 Volt and + 5 Volt, – 5 Volt.
  • INPUT 220, Volt, +_ 10%, 50 Hz.
  • OUTPUT CURRENT 500, mAmp in each output
  • LOAD REGULATION Better than +_ 0.1% for no load to full load
  • LINE REGULATION Better than +_ 0.5% for +_10% changes in mains.
  • PROTECTION These are protected against over loading and short circuiting.

+ 12 Volt 12 Volt and + 5 Volt 5 Volt. at 500 mAmp,

These are assembled with best components available, on glass epoxy printed circuit boards. 3 pin regulators are used in these Power Supplies. These are specified for 500, mAmp., current but can be used upto 600, mAmp if not used simultaneously. These are protected against short circuit and over loading.

Additional Information:

Payment Terms : L/C, T/T

Delivery Time : Depends on location

View Complete Details

Dual Power Supply (LV-30 B/2)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Condition New
  • Feature Proper Working, Superior Finish
  • Total Carbohydrate 1yr
  • LINE REGULATION Better than ± 0.05% for ± 10% changes in mains.
  • LOAD REGULATION Better than ± 0.05% from No load to full load.
  • RIPPLES Less than 1, mVolt rms at full load.
  • PROTECTION Protected against overloading and short circuiting
  • METERS Digital Meters fitted to read output voltage and current.
  • INTERNAL RESISTANCE ≤ 15, m ohm.
  • STABILITY ≤ 2.5, m Volt.
  • RECOVERY TIME ≤ 80, µS
  • TEMP. COEFFICIENT ≤ 0.05% + 5, mVolt/0C
  • SETTING RESOLUTION - VOLTAGE : App. 10, mVolt.
  • CURRENT : App. 2, mAmp.
  • INSULATION Between chassis output terminals. < 10, m ohm. at 100, Volts D.C. Between chassis AC Plug. < 50, M ohm. at 500, Volts D.C
  • POWER SUPPLY 230, Volt 10%, 50 Hz
  • NOTE: There may be any change in specification due to continuous R & D without notice.
  • Dual tracking or 2 independent output of 0 to 30 volts at 0 to 2 Amp
  • 4 digital meters for V & A measurements of both outputs

Additional Information:

Payment Terms : L/C, T/T,

Delivery Time : Depends on location

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us