Our Complete range of products are DC Regulated power supply (LV- 30/2) and 3 Phase S.R.C Based DC Power Supply (TPRU-100).

DC Regulated Power Supply (LV- 30/2)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2008 Certified, ISO 9001:2015
  • Application Electronic Goods
  • Total Carbohydrate 1yr
  • LINE REGULATION Better than ± 0.05% for ± 10% changes in mains.
  • LOAD REGULATION Better than ± 0.05% from No load to full load.
  • RIPPLES Less than 1, mVolt rms at full load.
  • PROTECTION Protected against overloading and short circuiting.
  • METERS Digital Meters fitted to read output voltage and current
  • INTERNAL RESISTANCE ≤ 15, m ohm.
  • STABILITY ≤ 2.5, m Volt.
  • RECOVERY TIME ≤ 80, µS
  • TEMP. CO-EFFECIENT ≤ 0.05% + 5, mVolt/0C
  • SETTING RESOLUTION : VOLTAGE App. 10, mVolt.
  • CURRENT App. 2, mAmp.
  • INSULATIONS Between chassis output terminals. < 10, m ohm. at 100, Volts D.C. Between chassis AC Plug. < 50, M ohm. at 500, Volts D.C
  • POWER SUPPLY 230, Volt 10%, 50 Hz.

0 - 30 Volt at Amp (LV -30/2),

By investing considerable amount and skilled labour we have developed these Power Supplies with unbeatable performance and capacity. We offer a wide range of Solid State Power Supplies at very competitive prices. The latest designs and technology are used. These power supplies exhibit extremely high level of reliability.

Additional Information:

Delivery Time : Depends on location

View Complete Details

3 Phase S.R.C Based DC Power Supply (TPRU-100)

  • Number Of Flower Dc Power Supply
  • Certification ISO 9001:2015
  • Application Electronic Goods
  • Feature Proper Working, Superior Finish, ** EXCELLENT STABILITY. ** ADJUSTABLE OUTPUT. ** COMPACT IN SIZE. ** PROTECTED AGAINST OVER LOADING
  • Total Carbohydrate 1yr
  • Output Voltage provided on D.C supply as S.C.R are voltage devices.
  • REGULATION Regulation is better than +1%.
  • RIPPLE Less than 5% on full load.
  • METERS Voltage and current meters are provided on the front door of the panel.
  • ANNUNCIATOR s provided on the door for easy diagnoses of faults.
  • DC VOLTAGE e setting is provided on the front door of the panel.
  • INPUT 3 Phase , 415 V ± 10% , 50 Hz
  • BURDEN RESISTANCE provided on D.C supply as S.C.R are voltage devices.
  • DC VOLTAGE build up has a smooth start features.

(rectifier type)

(Also available in 30A, 60A, 200A on demand ,

It employs D.C Converter 3phase fully controlled S.C.R Based Bridge converter with following features : Fault diagnosis and safety features : I. Instantaneous over current trip. II. Over load trip. III. Under Voltage/ Single phase trip. IV. Current limit with voltage fold back.

Additional Information: