Post Buy Requirement

Industrial Chemicals #921730

Descaling Chemicals

  • Type Chemical
  • Purity 99.80%
  • Appearance Liquid
  • Moisture ≤0.10%
  • Acidity ≤0.10 mgKOH/g
  • Specific weight(d204°C) 1.50±0.01
  • Boling Point 100 degree C

The company is a trusted Manufacturer, Exporter, and Supplier of high grade Descaling Chemicals (VCHEM 500) that is known to improve the performance and efficiency of the cooling water system. No plant shut-down is required while cleaning for cooling tower system. Shut down is required for the cleaning the scale in Boiler cleaning.

Known For
  • On - line cleaning of the cooling water systems to remove existing deposits
Demanded By
  • Beverage Industries
  • Pharmaceutical Plants
  • Food Industries
  • Oil Refineries
  • Power Plants
View Complete Details

Chiller Water Treatment Chemicals

  • Color Available in Many Colors
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • • pH 6.5 ± 1.5
  • • Sp. Gravity 1.05 ± 0.05
  • Shelf Life 6 months

The Chiller Water Treatment Chemicals inhibitor that we Manufacture, Export, and Supply, reduces the corrosion rates and enhances the life and efficiency of the equipment. Accurately formulated, our Chiller Water Treatment Chemicals inhibitor reduces the heat transfer rate and directly effects the cooling. This Chiller Water Treatment Chemicals inhibitor is hygienically packaged.

Recommended To
  • Use DM or Soft water in the Chillers along with regular dosing of VCHEM-1020
Dosage
  • At Initial stage : 10 Kilograms per M3 of water hold-up
  • Subsequently 3-4 Kilograms per M3 of Make-up
Packaged In
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums
View Complete Details

Boiler Water Treatment Chemical (VCHEM 101)

  • Type Boiler Water Treatment Chemicals
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Storage Store in a Cool Place

Boiler Water Treatment Chemical (VCHEM 101) is a sludge conditioner based on low molecular weight copolymer. This synthetic polymer is designed to produce light finely divided particles which are non adherent and easily removed in blowdown.

VCHEM 101 is highly stable and does not decompose under high pressure ( 100 Kg/Cm 2) and temperature.

Typical Properties :

  • Appearance : Amber liquid
  • Density : 1.1 approx.
  • pH : Alkaline Flash
  • Point : None
  • Volatility : Non -Volatile


Treatment :
VCHEM 101 is normally dosed so as to maintain the boiler water concentration between 100 to 500 mg/l in the boiler water. The correct treatment level for scale prevention depends on operating condition such as the boiler pressure and the alkalinity of the boiler water.

Dosing :
VCHEM 101 viscosity allows it to be dosed by conventional dosage pumps, without dilution, but it may be diluted if desired.

VCHEM 101 is not corrosive in concentrated or diluted form to steel mixing tanks or dosage pumps. Dosing direct to feed tank is recommended in single boiler installation.

Packing :
VCHEM 101 is available in 50 and 200 Ltrs drum.

Note : Boiler Water Treatment Chemical (VCHEM 101) finds applications in the following installations.

View Complete Details

Boiler Water Treatment Chemical (VCHEM 110)

  • Application Boiler Water Treatment
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid

We formulate Boiler Water Treatment Chemical (VCHEM 110) from quality materials. Effective against the sludge formed inside the Boiler drum, this (VCHEM 110) is a combination of phosphates with polymeric organic compounds. Our VCHEM-110 avoids crystallization of scale forming compounds. Our (VCHEM 110) forms magnesium hydroxide and calcium phosphate with magnesium ions and calcium ions. It contains polymeric compounds the prevent foaming in the boiler drum.

Used :

  • In medium pressure boilers
  • As a phosphate conditioning agent


Offered In :

  • 35 kilogram HDPE Drums
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums


Dosage :
In order to maintain boiler free from scaling, the dosage of VCHEM-110 should be regular as per our recommendations and the residuals to be maintained in the range of 15-30 ppm in the boiler drum. VCHEM-110 is to be dosed by means of a dosing pump either to the Boiler Drum or to feed water tank.

Precautions :
VCHEM-110 is non hazardous and non toxic chemical; however the contact with eyes should be avoided. Wash with excess water and seek medical advice in case of contact with eyes.

Specifications

pH 2 to 6
Physical State Liquid
Odour Odourless
Specific Gravity 1.05 ± 0.05

 

View Complete Details

Boiler Water Treatment Chemical (VCHEM 115)

  • Type Boiler Water Treatment Chemicals
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr

The Boiler Water Treatment Chemical (VCHEM 115) Oxygen Scavanger that we offer is a combination of various chemicals in the form of a crystalline powder. Our Boiler Water Treatment Chemical (VCHEM 115) Oxygen Scavanger searches the dissolved oxygen from the boiler-feed water. This (VCHEM 115) Oxygen Scavanger provides protection to the boiler. It has a catalyst which effects de-oxygenation.

Applicable To Boiler Operating At :

  • Low pressures
  • Medium pressures
  • High pressures


Offered In :

  • 35 kilogram HDPE Drums
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums


Dosage :
A 10-15% solution to be prepared in distilled or D M water and the dosing should be carried out in a closed system to avoid atmospheric contact. The dosing of VCHEM: 115 depend on the feed water temperature. Normally a residual of 20-30 ppm of VCHEM: 115 to be maintained in the boiler drum.

Precautions :

  • Though VCHEM : 115 is non hazardous chemical, it may cause irritation on the skin. In case of contact, wash with plenty of water.
  • Store VCHEM : 115 in dry and moist free conditions. The container to be sealed after use.

Specifications

Physical State Liquid
pH 7.5 - 8.5
Specific Gravity 1.050 ± 0.05

 

View Complete Details

Boiler Water Treatment Chemical (VCHEM 120)

  • Application Boiler Water Treatment
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr

We offer a premium Boiler Water Treatment Chemical (VCHEM 120) PH Booster that has form of a crystalline liquid. Boiler Water Treatment Chemical (VCHEM 120) PH Booster acts immediately to maintain the alkalinity inside the boiler-feed water. Being a catalyzed ph booster, it removes acidity from boiler-feed water. It has a catalyst which effects de-oxygenation.

Applicable To Boiler Operating At :

  • Low pressures
  • Medium pressures
  • High pressures


Dosage :
A 10-15% solution to be prepared in distilled or D M water and the dosing should be carried out in a closed system to avoid atmospheric contact.

Specifications

Physical State Liquid
pH 10 - 14
Special Gravity 1.050 ± 0.05

 

View Complete Details

Cooling Water Treatment Chemical (VCHEM 106)

  • Type Cooling Water Chemicals
  • Application Cooling Water
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr
  • Shelf life Long
  • Performance Optimum

Our Cooling Water Treatment Chemical (VCHEM 106) Micobicide has an ability of VCHEM-106 Micobicide to control the growth of microorganisms effectively. It combines with the cell wall and cytoplasmic membrane and after adsorption and infiltration of the cytoplasmic membrane forms colloidal solution with the cytoplasm and precipitates protein. This derives protein precipitation is known for the removal of bacteria.

Effectively Controls :

  • Bacteria
  • Fungi
  • Algae


Demanded For :

  • Paper mill water systems
  • Oil well brines
  • Drilling mud
  • Paints
  • Latex emulsions
  • Coating materials


Uses :

  • 100 to 200 PPm (Part Per million) Alternate week / Day

 

Precautions :
Avoid contact with eyes or prolonged contact skin. Do not take internally. In case of contact with skin, wash with plenty of water. In case of contact with eyes, flush water and get prompt medical aid.

Specifications

pH 10 ± 1
Appearance Liquid
Specific Gravity 1.0 ± 0.1
Colour Colorless to pale yellow liquid
Solubility in water Infinite

 

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Brijpal Sharma (Vishnu Chemicals)
  • Kh. No.447 , Gurunanak Nagar, Bhalaswa Dairy, Delhi - 110042, India
  • Share us via
  • Call 08068051321 Ext. 685
Retailer of Industrial Chemicals from Delhi, Delhi by Vishnu Chemicals
Post Buy Requirement

Industrial Chemicals #921730

Descaling Chemicals

  • Type Chemical
  • Purity 99.80%
  • Appearance Liquid
  • Moisture ≤0.10%
  • Acidity ≤0.10 mgKOH/g
  • Specific weight(d204°C) 1.50±0.01
  • Boling Point 100 degree C

The company is a trusted Manufacturer, Exporter, and Supplier of high grade Descaling Chemicals (VCHEM 500) that is known to improve the performance and efficiency of the cooling water system. No plant shut-down is required while cleaning for cooling tower system. Shut down is required for the cleaning the scale in Boiler cleaning.

Known For
  • On - line cleaning of the cooling water systems to remove existing deposits
Demanded By
  • Beverage Industries
  • Pharmaceutical Plants
  • Food Industries
  • Oil Refineries
  • Power Plants
View Complete Details

Chiller Water Treatment Chemicals

  • Color Available in Many Colors
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • • pH 6.5 ± 1.5
  • • Sp. Gravity 1.05 ± 0.05
  • Shelf Life 6 months

The Chiller Water Treatment Chemicals inhibitor that we Manufacture, Export, and Supply, reduces the corrosion rates and enhances the life and efficiency of the equipment. Accurately formulated, our Chiller Water Treatment Chemicals inhibitor reduces the heat transfer rate and directly effects the cooling. This Chiller Water Treatment Chemicals inhibitor is hygienically packaged.

Recommended To
  • Use DM or Soft water in the Chillers along with regular dosing of VCHEM-1020
Dosage
  • At Initial stage : 10 Kilograms per M3 of water hold-up
  • Subsequently 3-4 Kilograms per M3 of Make-up
Packaged In
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums
View Complete Details

Boiler Water Treatment Chemical (VCHEM 101)

  • Type Boiler Water Treatment Chemicals
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Storage Store in a Cool Place

Boiler Water Treatment Chemical (VCHEM 101) is a sludge conditioner based on low molecular weight copolymer. This synthetic polymer is designed to produce light finely divided particles which are non adherent and easily removed in blowdown. VCHEM 101 is highly stable and does not decompose under high pressure ( 100 Kg/Cm 2) and temperature. Typical Properties :

  • Appearance : Amber liquid
  • Density : 1.1 approx.
  • pH : Alkaline Flash
  • Point : None
  • Volatility : Non -Volatile

Treatment :VCHEM 101 is normally dosed so as to maintain the boiler water concentration between 100 to 500 mg/l in the boiler water. The correct treatment level for scale prevention depends on operating condition such as the boiler pressure and the alkalinity of the boiler water. Dosing :VCHEM 101 viscosity allows it to be dosed by conventional dosage pumps, without dilution, but it may be diluted if desired. VCHEM 101 is not corrosive in concentrated or diluted form to steel mixing tanks or dosage pumps. Dosing direct to feed tank is recommended in single boiler installation. Packing :VCHEM 101 is available in 50 and 200 Ltrs drum. Note : Boiler Water Treatment Chemical (VCHEM 101) finds applications in the following installations.

View Complete Details

Boiler Water Treatment Chemical (VCHEM 110)

  • Application Boiler Water Treatment
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid

We formulate Boiler Water Treatment Chemical (VCHEM 110) from quality materials. Effective against the sludge formed inside the Boiler drum, this (VCHEM 110) is a combination of phosphates with polymeric organic compounds. Our VCHEM-110 avoids crystallization of scale forming compounds. Our (VCHEM 110) forms magnesium hydroxide and calcium phosphate with magnesium ions and calcium ions. It contains polymeric compounds the prevent foaming in the boiler drum. Used :

  • In medium pressure boilers
  • As a phosphate conditioning agent

Offered In :

  • 35 kilogram HDPE Drums
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums

Dosage :In order to maintain boiler free from scaling, the dosage of VCHEM-110 should be regular as per our recommendations and the residuals to be maintained in the range of 15-30 ppm in the boiler drum. VCHEM-110 is to be dosed by means of a dosing pump either to the Boiler Drum or to feed water tank. Precautions :VCHEM-110 is non hazardous and non toxic chemical; however the contact with eyes should be avoided. Wash with excess water and seek medical advice in case of contact with eyes.

Specifications

pH 2 to 6
Physical State Liquid
Odour Odourless
Specific Gravity 1.05 ± 0.05

 

View Complete Details

Boiler Water Treatment Chemical (VCHEM 115)

  • Type Boiler Water Treatment Chemicals
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr

The Boiler Water Treatment Chemical (VCHEM 115) Oxygen Scavanger that we offer is a combination of various chemicals in the form of a crystalline powder. Our Boiler Water Treatment Chemical (VCHEM 115) Oxygen Scavanger searches the dissolved oxygen from the boiler-feed water. This (VCHEM 115) Oxygen Scavanger provides protection to the boiler. It has a catalyst which effects de-oxygenation. Applicable To Boiler Operating At :

  • Low pressures
  • Medium pressures
  • High pressures

Offered In :

  • 35 kilogram HDPE Drums
  • 50 kilogram HDPE Drums
  • 200 kilogram HDPE Drums

Dosage :A 10-15% solution to be prepared in distilled or D M water and the dosing should be carried out in a closed system to avoid atmospheric contact. The dosing of VCHEM: 115 depend on the feed water temperature. Normally a residual of 20-30 ppm of VCHEM: 115 to be maintained in the boiler drum. Precautions :

  • Though VCHEM : 115 is non hazardous chemical, it may cause irritation on the skin. In case of contact, wash with plenty of water.
  • Store VCHEM : 115 in dry and moist free conditions. The container to be sealed after use.

Specifications

Physical State Liquid
pH 7.5 - 8.5
Specific Gravity 1.050 ± 0.05

 

View Complete Details

Boiler Water Treatment Chemical (VCHEM 120)

  • Application Boiler Water Treatment
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr

We offer a premium Boiler Water Treatment Chemical (VCHEM 120) PH Booster that has form of a crystalline liquid. Boiler Water Treatment Chemical (VCHEM 120) PH Booster acts immediately to maintain the alkalinity inside the boiler-feed water. Being a catalyzed ph booster, it removes acidity from boiler-feed water. It has a catalyst which effects de-oxygenation. Applicable To Boiler Operating At :

  • Low pressures
  • Medium pressures
  • High pressures

Dosage :A 10-15% solution to be prepared in distilled or D M water and the dosing should be carried out in a closed system to avoid atmospheric contact.

Specifications

Physical State Liquid
pH 10 - 14
Special Gravity 1.050 ± 0.05

 

View Complete Details

Cooling Water Treatment Chemical (VCHEM 106)

  • Type Cooling Water Chemicals
  • Application Cooling Water
  • Color Blue
  • Purity 99%
  • Packaging Type Drum, Plastic Can
  • Physical State Liquid
  • Packaging Size 50ltr
  • Shelf life Long
  • Performance Optimum

Our Cooling Water Treatment Chemical (VCHEM 106) Micobicide has an ability of VCHEM-106 Micobicide to control the growth of microorganisms effectively. It combines with the cell wall and cytoplasmic membrane and after adsorption and infiltration of the cytoplasmic membrane forms colloidal solution with the cytoplasm and precipitates protein. This derives protein precipitation is known for the removal of bacteria. Effectively Controls :

  • Bacteria
  • Fungi
  • Algae

Demanded For :

  • Paper mill water systems
  • Oil well brines
  • Drilling mud
  • Paints
  • Latex emulsions
  • Coating materials

Uses :

  • 100 to 200 PPm (Part Per million) Alternate week / Day

 

Precautions :Avoid contact with eyes or prolonged contact skin. Do not take internally. In case of contact with skin, wash with plenty of water. In case of contact with eyes, flush water and get prompt medical aid.

Specifications

pH 10 ± 1
Appearance Liquid
Specific Gravity 1.0 ± 0.1
Colour Colorless to pale yellow liquid
Solubility in water Infinite

 

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Brijpal Sharma (Vishnu Chemicals)
  • Kh. No.447 , Gurunanak Nagar, Bhalaswa Dairy, Delhi - 110042, India
  • Share us via
  • Call 08068051321 Ext. 685