Our Products
We are leaders in the market for providing best range of Serological Water Bath, Horizontal Laminar Air Flow Cabinet, Air Velocity Control Laminar Air Flow Cabinet, Fully Automatic Control Laminar Air Flow Cabinet and Basic Fume Hood
Waiometra Serological water baths are used for clinical procedure, Incubation, Inactivation, Agglutination, as well as most serological pharmaceutical, biomedical procedure, Washer man, Kolmer and Khan Test inactivation's, Paraffin Embedding and many other applications in the laboratories. We specialize in both standard and customized models, specifically designed to meet the challenging demands of various test areas.
Waiometra High Precision Water Bath is suitable for Biotechnology, Clinical, Environmental, Medical, Petroleum, Pharmaceutical or Industrial Applications.
| Serological pharmaceutical, biomedical procedure. |
| Research laboratories |
Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. Horizontal Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirection velocity flowing in parallel lines, which is free from macroscopic fluctuations. The horizontal laminar air flow units direct the air in mono direction which is away from the specimen and towards the user, giving ultimate protection to the product, which is susceptible to contamination induced by diffusion of contaminated air carrying air transported contaminants from the outside environment.
Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. Horizontal Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirection velocity flowing in parallel lines, which is free from macroscopic fluctuations. The horizontal laminar air flow units direct the air in mono direction which is away from the specimen and towards the user, giving ultimate protection to the product, which is susceptible to contamination induced by diffusion of contaminated air carrying air transported contaminants from the outside environment.
Features :
| Programmable UV Light to allow specific exposure time from 0 to 60 minute with automatic shut-off features UV interlocking with front window i.e. closed automatically when front window is open. |
| Fully Automatic Microprocessor Controlled. |
| Automatically adjustment of motor speed to ensure safe airflow. |
| LCD/LED display of Air Velocity, Alarm for Undershoot / Overshoot of Air Velocity. |
| Password protection (Programmable) for authorised operation. |
| Initial self cleaning cycle with programmable time. |
| UV timer showing used time and balance available life in hours. |
| Total HEPA Filter timer showing used time and balance available life in hour. |
| HEPA filter alarm after HEPA filter life is over and guideline for further action through LCD controller. |
| Audio Visual door unsafe alarm, if door is at incorrect operating height. |
| UV light/Door/Fluorescent Light Inter Lock i.e. UV switches ON only when door is closed, and automatically switches OFF fluorescent lights. |
| If UV light is ON & the operator tries to open the door, it raises audio visual alarm. |
| Display of safe / unsafe position for door. |
Waiometra Fume Hood based on the principle to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure in a laboratory. name_icon Fume Hoods capture the fumes released during an experiment by drawing fresh air from the environment, pass the user & get into the unit. This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. The velocity of the air is controlled at approximately 80 to 130 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases.
WaiometraFume Hood is based on the principle to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure.
Waiometra Fume Hoods capture the fumes released during an experiment by drawing fresh air from the environment, pass the user and get into the unit. This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. The velocity of the air is controlled at approximately 80 to 130 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases
Waiometra CO2 Incubator is based on the principle to maintain optimal temperature, humidity and carbon dioxide (CO2) and oxygen content of the atmosphere inside.
Features :
| Humidity range 95% RH. |
| Interior chamber shall be made of Stainless Steel with 2 trays. |
| Over temperature protection Controller. |
| Double stage CO2 pressure regulator & CO2 Cylinder (Optional). |
Waiometra B.O.D. Incubator is based on the principle to provide preset controlled temperature conditions in an enclosed area irrespective of the changes in the ambient conditions of the environment.
Featrues :
| CFC free refrigerant. |
| Long life. |
| Low Maintenance. |
| Guaranteed supply of Spares & Service for 10 years. |
| Onsite installation and after sales service by company trained engineers. |
Waiometra Bacteriological Incubator is based on three side heating system. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temp. sensitivity.
Features :
Controller mounted on the door (no separate panel)
|
|
|
|
|
|
| 70% higher uses through trouble free adjustment of trays anywhere at a gap 4cms. |
Waiometra Bacteriological Incubator is based on three side heating system. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temp. sensitivity.
Features :
| Feather Touch LED +LCD both display with Digital Timer. |
| Once the set temperature is attained, timer starts working automatically . |
| Raises alarm if the temperature overshoots/undershoots. |
| Continuous display on L.C.D. of Set Temp., Attained Temp., Set Time, Heating On/Off. |
| Display of door open (if door is not closed) & heater gets switched off. |
| Indicators of Auto-mode, Sensor failure, Alarm & Heating. |
| 70% higher uses through trouble free adjustment of trays anywhere at a gap 4cms. |
Waiometra Hot Air Oven is based on three side heating system. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temp. uniformity.
Features :
| Feather Touch LED + LCD both display with Digital Timer. |
| OOnce the set temperature is attained, timer starts working automatically . |
| Raises alarm if the temperature overshoot/ undershoot. |
| Continuous display on L. C. D. of Set Temp., Attained Temp., Set Time, Heating On/Off. |
| Display of door open (if door is not closed) & heater gets switched off automatically. |
| Indicators of Auto-mode, Sensor failure, Alarm & Heating. |
| 70% higher use through trouble free adjustment of trays anywhere at a gap 4cms. |
Waiometra Hot Air Oven Perfect System is Triple walled based on the principle of heating through injection of hot air in the inner chamber to provide high accuracy & distribution of temp. throughout the chamber.
Features :
| Feather Touch LED +LCD both display with Digital Timer. |
| Once the set temperature is attained, timer starts working automatically |
| Raises alarm if the temperature overshoots/undershoots. |
| Display of door open (if door is not closed) & heater gets switched off automatically. |
| Continuous display on L.C.D. of Set Temp., Attained Temp., Set Time, Heating On/Off. |
| Display of Door open (if door is not closed) & heater gets switched off. |
| Indicators of Auto-mode, Sensor failure, Alarm & Heating |
| 70% higher use through trouble free adjustment of trays anywhere at a gap 4cms |
Waiometra environmental chamber is based on the principle to provide preset controlled temperature & humidity condition in an enclosed chamber.
An Environmental Chambers are used to heat or cool samples while testing the effects of specified environmental conditions on biological items, industrial products, materials, and electronic devices and components. It is ideal for use in Research & Development Laboratories, Q.C. Lab. etc.
| Electronics industry |
| PCB designing |
| Automotive industry |
Waiometra B.O.D. Incubator Shaker is based on the principle to provide preset controlled temperature clubbed with rotation of material at preset controlled RPM.
Ideal for research & development laboratories, industrial, medicine, for biochemical's oxygen demand enzymatic, serum & sewage studies, storage of heat sensitive vaccines, insulin lever extract pharmacy medicines etc.
| Research Laboratories |
| Educational Institutes |
| R& D laboratories |
| Medical & Pharma |
Waiometra High Precision Water Bath is based on the principle to provide temperature application to specific fluids in a bath tank.
Waiometra High Precision Water Bath is suitable for Biotechnology, Clinical, Environmental, Medical, Petroleum, Pharmaceutical or Industrial Applications.
| Laboratory Applications |
| Warming of reagents |
| Melting of substrates |
| Incubation of cell cultures |
| Bacterial examination |
| Crude oil analysis |
| Food processing |
| Immunology testing |
| Protein analysis |
| Thawing samples |
Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. VERTICAL Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirection velocity flowing in vertical downward, which is free from macroscopic fluctuations. The Vertical laminar air flow unit directs the air in mono direction which is away from user and towards the products, giving ultimate protection to the user.
Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. VERTICAL Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirection velocity flowing in vertical downward, which is free from macroscopic fluctuations. The Vertical laminar air flow unit directs the air in mono direction which is away from user and towards the products, giving ultimate protection to the user.
Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. Horizontal Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirectional velocity flowing in parallel lines, which is free from macroscopic fluctuations. The horizontal laminar air flow units direct the air in mono direction which is away from the specimen and towards the user, giving ultimate protection to the product, which is susceptible to contamination induced by diffusion of contaminated air carrying air transported contaminants from the outside environment.
Features :
Features :