Our Products
Our offered Product range includes Thermal Shock Test Chamber (HT-2145A) and Surface Roughness Tester.
The transfer time of this Thermal Shock Test Chamber is within 10 seconds, meeting MIL, IEC, JIS standards. And the recovery time ofthis chamber is within 5 minutes, which is available to meet various international standards. Graphic LCD display with ChineseEnglish dualselectioin for direct operation.
Specifications
| Type | 401 | 402 | 403 | 501 | 502 | 503 | 601 | 602 | 603 |
| Test area space (WxHxD) cm |
35x35x40 | 50x40x40 | 60x50x50 | 35x35x40 | 50x40x40 | 60x50x50 | 35x35x40 | 50x40x40 | 60x50x50 |
| FHigh temp. range | +80 C~ +200 C | +80 C~ +200 C | +80 C~ +200 C | ||||||
| Low temp. range | +10 C~ +45 C | +10 C~ +45 C | +10 C~ +45 C | ||||||
| Test area temp. range |
+60 C~ +150 C 0 C~ -4 C |
+60 C~ +150 C -10 C~ -55 C |
+60 C~ +150 C -10 C~ -65 C |
||||||
| Heat-up speed | Rt ~ +200 C about 25 min (Room temp range 10C ~ 30C) | ||||||||
| Cool-down speed | Rt ~ -70 C about 70 min (Room temp range 10C ~ 30C) | ||||||||
| Recover speed | 5Within 5 min | ||||||||
| Temp. accuracy | +-2 C | ||||||||
| Insulation material | High temp. area: High-density glass wool / Low tem. Area: rigid polyurethane foam / test area: high-density glass fiber wool + rigid Polyurethane foam |
||||||||
| Valve driving apparatus |
pneumatic cylinder | ||||||||
| Controller | FUJI user-friendly interface control system, 7.7color LCD touch panel display | ||||||||
| Safety devices | over-temperature protec tion for high/low temperature area, transducer trouble detector, compressor overload protecting switch, pneumatic protection switch, water flow protection switch, 3-phase monitoring relay, Non-fuse breaker |
||||||||
| Air pressure | 5 ~ 8 kg/cm2 | ||||||||
| Water pressure | 2 kg/cm2 | ||||||||
| Water pipe diameter | in/out 4.2 m3/hr | ||||||||
| Water pipe diameter | 11/2inch | ||||||||
| Power | 3Ø, 220 V, 75 A or 3Ø, 380 V, 60 A | 3Ø, 220 V, 100 A or 3Ø, 380 V, 75 A |
3Ø,220V, 75A or 3Ø,380V, 60A |
3Ø, 220 V, 100 A or 3Ø, 380 V, 75 A |
|||||
| Dimensions (WxHxD) cm |
150x187 x153 |
171x192 x153 |
181x207 x153 |
156x187 x153 |
171x192 x153 |
181x207 x153 |
156x187 x153 |
171x192 x153 |
181x207 x153 |
| Weight kg | 900 | 1200 | 1500 | 900 | 1200 | 1500 | 900 | 1200 | 1500 |