We offer the best product range of NOX Stack Gas Monitor and Online Dust Emission Monitor.

NOX Stack Gas Monitor

  • Measurement Method  Chemiluminescence
  • Measuring Range  0-100 / 0-1000 / 0-2000 ppm
  • Data Display  Large OLED display
  • Lower Detection Limit  0.1 ppm
  • Resolution  0.1 ppm/1ppm( for 0-1000 & 0-2000 ppm range)
  • Communication Port  RS-232 / RS-485 & USB
  • Current Output  4-20 mA
  • Analog -Digital I/O  DB 15 F Socket
  • Data logging  Supports Internal data logging
  • Operation Temperature  5℃ - 40℃
  • Dimensions (cm)  42 x16.2 x 61.2 (w x h x d)
  • Power  230 VAC

Chemiluminescence has long been recognized as the best practical analytical method for NOx detection at parts per billion level and with little or no interference from other pollutant gases. A sample containing nitric oxide is mixed with a large quantity of ozone. The nitric oxide reacts with the ozone to produce nitrogen dioxide in excited state. These excited molecules relaxes to ground state by emitting light in the region 600-2800nm which is measured using a photomultiplier Tube. The amount of light produced is proportional to the amount of nitric oxide in the sample.

FEATURES:

  • Measurement based on Chemiluminescence technique
  • Internal ozone generation
  • Fast and reliable analysis
  • On board memory , store up to 1500 test results along with time and date
  • Minimum maintenance
  • Suitable for stack gas monitoring


APPLICATIONS:

  • Continuous Emissions Monitoring
  • Combustion efficiency
  • Vehicle emission
  • Personal safety
  • Mobile Van / laboratory
View Complete Details

Online Dust Emission Monitor

  • Accuracy : + 2 %
  • Country of Origin 240 VAC ( + 10 % Voltage tolerance)
  • Availability 2.5 kg (TX or reflector head plus Aluminium Air Purge Body) 1.3 kg (OI wall mounted/ OI panel mounted)  
  • Path length 0.5-10 m (Flange to flange Separation)
  • Range 0-1000 mg/m3 or in mg/Nm3 (Higher available on request)
  • Resolution 0.1 mg/m3
  • Damping 1-60 sec
  • Nominal Current Consumption 500 mA
  • Air supply volume flow 50-200 L/min
  • Cable & Wire Operator Interface/TRX interconnection: Screened multi core
  • Analog Output            4-20 mA (Isolated and scalable)
  • Digital Relay Contacts 2 contacts
  • Heads ingress protection  IP 65
  • OI protection                  Wall mounted (IP 65) & Panel Mounted (IP 64)
  • Operating Humidity        Upto 100 % (Air humidity around heads)
  • Gas temperature             +600 degree C

Salient Features

  • Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes.
  • Dynamic Detection Principle (DDP) measurement technique results in increased immunity to drift
  • Measurement reading as mg/m3(when calibrated against standard reference measurements)
  • Internal electronic calibration check facility
  • Rugged 316 stainless steel construction
  • Choice of interface options enabling easy integratio


Cleaning Cycle

  • Generally in a dust monitor, regular maintenance involves cleaning optical surface. Our systems are easily accessible due latched head design.
  • Toovercome manual cleaning, the systems come with apurge air systemwhich when connectedkeeps the contaminated stack gas away for the lens surfaces.
  • An aluminum air purge body is available for use on standard installations and a more advanced stainless steel body for more demanding installations.


APPLICATIONS:

Cement Plants
Steel Plants
Sponge Iron Plant
Power Plant
Oil & Gas industries.