Post Buy Requirement
WS
Kolkata, West Bengal, India
Add Review

Other Products / Services #2886871

Draeger Gas Detector

48,000 /Piece Get Latest Price
  • Detector Type Portable Multi Gas
  • Model X-am 2500
  • Name of Gases Detected LEL, O2, H2S, CO
  • Brand Draeger
View Complete Details

Oil Spectrophotometer

  • Detector Silicon Photodiode
  • Weight 1 kg
  • Data Output Port RS 232
  • Display Digital
  • Usage / Application Food Processing Industries, FMCG Industrial Use
  • Dimensions 8.5*16.2*6.7 cm

Instrument Type

Tri LED Colorimeter

Measurement range

0.0 to 100 % Oxygen

Readable Resolution

Determined by test factor.

Measuring Ions

Iron, Nickel, Copper & Phosphorus from oil

Range

Iron, Nickel, Copper = 0.2-2 ppm +/- 0.05 ppm
Inorganic Phosphorus = 0.05-0.7 ppm +/- 0.01 ppm

Response Time

20 sec

Warm-up Time

5 min

Lamp

Tri-LED

Detector

Silicon Photodiode

Physical Dimensions

8.5*16.2*6.7 cm, Weight=1 Kg

Serial Interface

Rs-232

Power

Battery Operated:4.8 V NiMH

Sample Pump

Diaphragm pump

Sampling assembly

Probe with needle, PTFE tubing


View Complete Details

Gas Detector Tube


The precision gas detector tube system consists of two parts viz. 1) the Gas Detector Tube & 2) Air Sampling Pump.
Detector Tube is a glass tube filled with gas specific sensing chemical & sealed at both ends. The tube indicates the target gas concentration directly on the scale printed on the detector tube.
Available for NH3, H2S, SO2, CL2, PH3, HCL, HCN, CO, CO2, O2, C6H6, alcohols, amines, mercaptans and 120 other gases and vapors with over 200 ranges.






FEATURES:


  • Efficientand spot check of toxic gas concentration at work place at specified intervals.

  • No requirement of complicated accessories.

  • No requirement of specialist to operate.

  • It is pre calibrated and requires minimum maintenance Specific to target gas.

  • Available for most of the industrial toxic gases and organic vapours.




APPLICATIONS:


  • Petrochemical & Refineries

  • Pharmaceutical

  • Chemical & Fertilizer

  • Fumigation

  • Food Industry

  • Pulp & Paper Mills Industries

  • Power & Steel Plants

  • Municipal Corporations

  • Environmental monitoring agencies and many more



View Complete Details

NOX Stack Gas Monitor

  • Measurement Method  Chemiluminescence
  • Measuring Range  0-100 / 0-1000 / 0-2000 ppm
  • Data Display  Large OLED display
  • Lower Detection Limit  0.1 ppm
  • Resolution  0.1 ppm/1ppm( for 0-1000 & 0-2000 ppm range)
  • Communication Port  RS-232 / RS-485 & USB
  • Current Output  4-20 mA
  • Analog -Digital I/O  DB 15 F Socket
  • Data logging  Supports Internal data logging
  • Operation Temperature  5℃ - 40℃
  • Dimensions (cm)  42 x16.2 x 61.2 (w x h x d)
  • Power  230 VAC

Chemiluminescence has long been recognized as the best practical analytical method for NOx detection at parts per billion level and with little or no interference from other pollutant gases. A sample containing nitric oxide is mixed with a large quantity of ozone. The nitric oxide reacts with the ozone to produce nitrogen dioxide in excited state. These excited molecules relaxes to ground state by emitting light in the region 600-2800nm which is measured using a photomultiplier Tube. The amount of light produced is proportional to the amount of nitric oxide in the sample.


FEATURES:



  • Measurement based on Chemiluminescence technique

  • Internal ozone generation

  • Fast and reliable analysis

  • On board memory , store up to 1500 test results along with time and date

  • Minimum maintenance

  • Suitable for stack gas monitoring



APPLICATIONS:



  • Continuous Emissions Monitoring

  • Combustion efficiency

  • Vehicle emission

  • Personal safety

  • Mobile Van / laboratory

View Complete Details

Online Dust Emission Monitor

  • Accuracy : + 2 %
  • Voltage 240 VAC ( + 10 % Voltage tolerance)
  • Weight 2.5 kg (TX or reflector head plus Aluminium Air Purge Body) 1.3 kg (OI wall mounted/ OI panel mounted)  
  • Path length 0.5-10 m (Flange to flange Separation)
  • Range 0-1000 mg/m3 or in mg/Nm3 (Higher available on request)
  • Resolution 0.1 mg/m3
  • Damping 1-60 sec
  • Nominal Current Consumption 500 mA
  • Air supply volume flow 50-200 L/min
  • Cable & Wire Operator Interface/TRX interconnection: Screened multi core
  • Analog Output            4-20 mA (Isolated and scalable)
  • Digital Relay Contacts 2 contacts
  • Heads ingress protection  IP 65
  • OI protection                  Wall mounted (IP 65) & Panel Mounted (IP 64)
  • Operating Humidity        Upto 100 % (Air humidity around heads)
  • Gas temperature             +600 degree C

Salient Features



  • Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes.

  • Dynamic Detection Principle (DDP) measurement technique results in increased immunity to drift

  • Measurement reading as mg/m3(when calibrated against standard reference measurements)

  • Internal electronic calibration check facility

  • Rugged 316 stainless steel construction

  • Choice of interface options enabling easy integratio



Cleaning Cycle



  • Generally in a dust monitor, regular maintenance involves cleaning optical surface. Our systems are easily accessible due latched head design.

  • Toovercome manual cleaning, the systems come with apurge air systemwhich when connectedkeeps the contaminated stack gas away for the lens surfaces.

  • An aluminum air purge body is available for use on standard installations and a more advanced stainless steel body for more demanding installations.



APPLICATIONS:

Cement Plants
Steel Plants
Sponge Iron Plant
Power Plant
Oil & Gas industries.

Note- Analyzer for other gases like HCL, Cl2, O2, CO, NH3, CO2 etc with different range can also be provided.

View Complete Details

LPG Gas Detector

  • Power Source Plug-In
  • Display Type Digital
  • Country of Origin Made in India
  • Feature Relay output for automatic activation of exhaust fan, hooter, solenoid valve etc,  Alarm acknowledgement / reset and mute keys on both local and remote consoles.
  • Name of Gases Detected LPG
  • Detector Type Fixed Single Gas
  • Measuring Range 0 TO 100 % LEL
  • Power supply 230 VAC, 50 Hz
View Complete Details

Chemical Mask

25,000 /unit Get Latest Price
  • Material Chemical resistant & flame retardant material
  • Size 210X160X150 mm
  • Color Yellow
  • Weight 700 gm
  • Temperature -20 to 55 degree C
  • Fire Resistance Yes
View Complete Details

Radar Level Transmitter

80,000 /Piece Get Latest Price
  • Type Digital
  • Material Stainless Steel
  • Application Industrial
  • Measuring Range Upto120 Meter
  • Process Temperature -40.+200°C
  • Power Supply 24 V DC
  • Accuracy  "+/- 2 mm
  • Min. process pressure in bar 1 bar
  • Max. process pressure in bar 3 bar
View Complete Details

Portable Gas Detector

  • Power Source One 9V replaceable alkaline battery
  • Certification Intrinsic Safety (By CMRI Dhanbad)- EEx ia IIB T4  
  • Flamable Catalytic Bead Detector / Non Dispersive InfraRed Detector (NDIR)
  • Toxic & O2 Electrochemical
  • CO2 NDIR
  • VOC       Photo  ionization Detector (PID)
  • Accuracy Inherently +/- 2% (but also depends on the accuracy of the calibration gas & method)
  • Sampling Diffusion
  • Display 3½ Digit LCD Display with low battery display
  • Hi & Lo Alarm View Keys To view the alarm set-points
  • Electronic Alarm 85 db Audio Alarm, Visual LEDs
  • Battery life Approx. 100 hrs
  • Operating Temperature Range 0 to +50 °C
  • Operating Pressure Ambient +/- 10%
  • Enclosure ABS
  • Weight 230 grams
  • Standard Accessories Carrying Case & Screw driver
  • Dimension H × W × D: 175 × 85 × 30 mm

Portable Gas Detector is a simple and compact instrument, designed to protect personnel from the hazards of toxic and combustible gases. A certified and affordable solution ideal for a wide range of applications.It is available in single gas monitor as well as multi gas monitor. In multi gas monitor it measures upto 4 gases simultaneously.
In Multi Gas Detector it will detect LEL, O2, H2S, CO simultaneously.





FEATURES:

High specificity to gas of concern.
Long sensor life.
Quick response.
Continuous display of the gas concentration reading.
Built-in audible and visual alarms.
Easy to read LCD display.


GAS DETECTED:

Carbon Monoxide, Flammable, O2, Bromine, Chlorine, Diborane, Formaldehyde, H2, HCL, Carbon disulphide, HCN, HF, Hydrazine, Hydrogen Sulphide, NH3, NO2, Vinyl Chloride, Ethyl Mercaptan, Phosphine, Sulpher dioxide, Ammonia, Silane, Phosgene, VOC.


APPLICATIONS:

Confined Spaces
Fumigation
Occupational Safety & Health
Oil & Gas
Petrochemical Plants
Process Control
Research Laboratories
View Complete Details

Fixed Gas Detector

  • Flamable Catalytic Bead Detector / Non Dispersive InfraRed Detector (NDIR)
  • Toxic Electrochemical
  • VOC       Photo  ionization Detector (PID)
  • Dimension 230MM*220MM*120MM, Weight-2.5 Kg (Approx)
  • Enclosure & Mounting Flame proof, Cast Aluminum Alloy. Mounting on walls or poles or similar support
  • Operating Voltage & Power 18 to 28 VDC (Typically 24 VDC), Power-Less than 3 Watt.
  • Operating Temp -20 to 50 degree C
  • Operating Pressure & Humidity Ambient +/-10% and  0-95% RH (Non Condensing)
  • Output 4-20 mA and RS-485 (MOD-BUS)
  • Standards complied IS/IEC:60079-0:2004 IS/IEC:60079-1:2007 IP-IS/2063-1987(IEC60529:2001)
  • Certification CCOE & CIMER certified to Exd IIC, T6, IP66 (Cat No-UJB20130) ATEXExII2GExdIICT6GbTamb-20 degree C to + 40 degree C, in process.

Digital Universal Gas Transmitter is a field mounted gas detector for the continuous monitoring of hazardous & combustible gases. It provides an industry standard 4-20 mA output signal that can be connected to any control system (DCS, PLC, etc.). It also provides RS-485 MODBUS-RTU digital output signal. It is available for a large variety of toxic and flammable gases such as Combustibles, Oxygen, Carbon Monoxide, Hydrogen Sulfide, Ammonia, Chlorine, SO2, NH3, HCN, HCL, NO2 etc




APPLICATIONS:


  • Refineries

  • Petrochemicals

  • Pharmaceuticals

  • Power Industries

  • Pollution control monitoring

  • Oil & Gas Industry.







View Complete Details

Flammable Gas Leak Detector

  • Detector Heads & Alarm Indicator Console Each console can handle up to 10 detector heads
  • Display Power ON Indicator LED for each detector head.
  • Function Keys      Membrane switch for alarm acknowledgement & mute
  • Alarms Visual & 107dB Audio Hooter Alarm at Alarm Indicator Consoles. Visual flashing LEDs on detector heads
  • Relay Output Potential Free SPDT relay contact provision at local and remote Alarm Indicator Consoles
  • Power supply 230 VAC, 50 Hz mains supply (SMPS) for digital receivers
  • Self Test Pre-programmed 'self test' checks sensor integrity, alarm functions and system functioning
  • Size Detector heads: 110 mm diameter

Flammable Gas Monitoring System is a novel state of the art leak detection system. Designed for permanent installation, the unit is able to monitor the presence of combustible gases such as LPG, CNG, LNG etc. in a variety of applications.

FEATURES:
Microprocessor based system with in-built self-test facility & RS 485 digital data communication link.
CMRI / CCOE certified Gas Leak Detector heads continuously monitors the presence of flammable gases.
Local & an optional Remote Alarm Indicator console provides audio-visual alarm status from all detector heads.
Relay output for automatic activation of exhaust fan, hooter, solenoid valve etc.
Alarm acknowledgement / reset and mute keys on both local and remote consoles.


APPLICATIONS:



  • LPG/CNG/LNG

  • Gas storage area

  • LPG Bullet & Banks

  • Plant Locations

  • Hotel Kitchens

  • Industrial Canteens

  • Gas Filling Stations

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Websoft Solution (Websoft Solution)
  • 83/65 RASHKHOLA ROAD, KHARDAH , Khardaha, Kolkata, West Bengal - 700117, India
  • Share us via
List of Other Products by Websoft Solution from Kolkata, West Bengal.
Post Buy Requirement
WS
Kolkata, West Bengal, India
Add Review

Other Products / Services #2886871

Draeger Gas Detector

48,000 /Piece Get Latest Price
  • Detector Type Portable Multi Gas
  • Model X-am 2500
  • Name of Gases Detected LEL, O2, H2S, CO
  • Brand Draeger
View Complete Details

Oil Spectrophotometer

  • Detector Silicon Photodiode
  • Weight 1 kg
  • Data Output Port RS 232
  • Display Digital
  • Usage / Application Food Processing Industries, FMCG Industrial Use
  • Dimensions 8.5*16.2*6.7 cm

Instrument Type

Tri LED Colorimeter

Measurement range

0.0 to 100 % Oxygen

Readable Resolution

Determined by test factor.

Measuring Ions

Iron, Nickel, Copper & Phosphorus from oil

Range

Iron, Nickel, Copper = 0.2-2 ppm +/- 0.05 ppm
Inorganic Phosphorus = 0.05-0.7 ppm +/- 0.01 ppm

Response Time

20 sec

Warm-up Time

5 min

Lamp

Tri-LED

Detector

Silicon Photodiode

Physical Dimensions

8.5*16.2*6.7 cm, Weight=1 Kg

Serial Interface

Rs-232

Power

Battery Operated:4.8 V NiMH

Sample Pump

Diaphragm pump

Sampling assembly

Probe with needle, PTFE tubing


View Complete Details

Gas Detector Tube

The precision gas detector tube system consists of two parts viz. 1) the Gas Detector Tube & 2) Air Sampling Pump.Detector Tube is a glass tube filled with gas specific sensing chemical & sealed at both ends. The tube indicates the target gas concentration directly on the scale printed on the detector tube.Available for NH3, H2S, SO2, CL2, PH3, HCL, HCN, CO, CO2, O2, C6H6, alcohols, amines, mercaptans and 120 other gases and vapors with over 200 ranges.

FEATURES:
  • Efficientand spot check of toxic gas concentration at work place at specified intervals.
  • No requirement of complicated accessories.
  • No requirement of specialist to operate.
  • It is pre calibrated and requires minimum maintenance Specific to target gas.
  • Available for most of the industrial toxic gases and organic vapours.


APPLICATIONS:
  • Petrochemical & Refineries
  • Pharmaceutical
  • Chemical & Fertilizer
  • Fumigation
  • Food Industry
  • Pulp & Paper Mills Industries
  • Power & Steel Plants
  • Municipal Corporations
  • Environmental monitoring agencies and many more
View Complete Details

NOX Stack Gas Monitor

  • Measurement Method  Chemiluminescence
  • Measuring Range  0-100 / 0-1000 / 0-2000 ppm
  • Data Display  Large OLED display
  • Lower Detection Limit  0.1 ppm
  • Resolution  0.1 ppm/1ppm( for 0-1000 & 0-2000 ppm range)
  • Communication Port  RS-232 / RS-485 & USB
  • Current Output  4-20 mA
  • Analog -Digital I/O  DB 15 F Socket
  • Data logging  Supports Internal data logging
  • Operation Temperature  5℃ - 40℃
  • Dimensions (cm)  42 x16.2 x 61.2 (w x h x d)
  • Power  230 VAC

Chemiluminescence has long been recognized as the best practical analytical method for NOx detection at parts per billion level and with little or no interference from other pollutant gases. A sample containing nitric oxide is mixed with a large quantity of ozone. The nitric oxide reacts with the ozone to produce nitrogen dioxide in excited state. These excited molecules relaxes to ground state by emitting light in the region 600-2800nm which is measured using a photomultiplier Tube. The amount of light produced is proportional to the amount of nitric oxide in the sample.

FEATURES:

  • Measurement based on Chemiluminescence technique
  • Internal ozone generation
  • Fast and reliable analysis
  • On board memory , store up to 1500 test results along with time and date
  • Minimum maintenance
  • Suitable for stack gas monitoring


APPLICATIONS:

  • Continuous Emissions Monitoring
  • Combustion efficiency
  • Vehicle emission
  • Personal safety
  • Mobile Van / laboratory
View Complete Details

Online Dust Emission Monitor

  • Accuracy : + 2 %
  • Voltage 240 VAC ( + 10 % Voltage tolerance)
  • Weight 2.5 kg (TX or reflector head plus Aluminium Air Purge Body) 1.3 kg (OI wall mounted/ OI panel mounted)  
  • Path length 0.5-10 m (Flange to flange Separation)
  • Range 0-1000 mg/m3 or in mg/Nm3 (Higher available on request)
  • Resolution 0.1 mg/m3
  • Damping 1-60 sec
  • Nominal Current Consumption 500 mA
  • Air supply volume flow 50-200 L/min
  • Cable & Wire Operator Interface/TRX interconnection: Screened multi core
  • Analog Output            4-20 mA (Isolated and scalable)
  • Digital Relay Contacts 2 contacts
  • Heads ingress protection  IP 65
  • OI protection                  Wall mounted (IP 65) & Panel Mounted (IP 64)
  • Operating Humidity        Upto 100 % (Air humidity around heads)
  • Gas temperature             +600 degree C

Salient Features

  • Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes.
  • Dynamic Detection Principle (DDP) measurement technique results in increased immunity to drift
  • Measurement reading as mg/m3(when calibrated against standard reference measurements)
  • Internal electronic calibration check facility
  • Rugged 316 stainless steel construction
  • Choice of interface options enabling easy integratio


Cleaning Cycle

  • Generally in a dust monitor, regular maintenance involves cleaning optical surface. Our systems are easily accessible due latched head design.
  • Toovercome manual cleaning, the systems come with apurge air systemwhich when connectedkeeps the contaminated stack gas away for the lens surfaces.
  • An aluminum air purge body is available for use on standard installations and a more advanced stainless steel body for more demanding installations.


APPLICATIONS:

Cement Plants
Steel Plants
Sponge Iron Plant
Power Plant
Oil & Gas industries.

Note- Analyzer for other gases like HCL, Cl2, O2, CO, NH3, CO2 etc with different range can also be provided.

View Complete Details

LPG Gas Detector

  • Power Source Plug-In
  • Display Type Digital
  • Country of Origin Made in India
  • Feature Relay output for automatic activation of exhaust fan, hooter, solenoid valve etc,  Alarm acknowledgement / reset and mute keys on both local and remote consoles.
  • Name of Gases Detected LPG
  • Detector Type Fixed Single Gas
  • Measuring Range 0 TO 100 % LEL
  • Power supply 230 VAC, 50 Hz
View Complete Details

Chemical Mask

25,000 /unit Get Latest Price
  • Material Chemical resistant & flame retardant material
  • Size 210X160X150 mm
  • Color Yellow
  • Weight 700 gm
  • Temperature -20 to 55 degree C
  • Fire Resistance Yes
View Complete Details

Radar Level Transmitter

80,000 /Piece Get Latest Price
  • Type Digital
  • Material Stainless Steel
  • Application Industrial
  • Measuring Range Upto120 Meter
  • Process Temperature -40.+200°C
  • Power Supply 24 V DC
  • Accuracy  "+/- 2 mm
  • Min. process pressure in bar 1 bar
  • Max. process pressure in bar 3 bar
View Complete Details

Portable Gas Detector

  • Power Source One 9V replaceable alkaline battery
  • Certification Intrinsic Safety (By CMRI Dhanbad)- EEx ia IIB T4  
  • Flamable Catalytic Bead Detector / Non Dispersive InfraRed Detector (NDIR)
  • Toxic & O2 Electrochemical
  • CO2 NDIR
  • VOC       Photo  ionization Detector (PID)
  • Accuracy Inherently +/- 2% (but also depends on the accuracy of the calibration gas & method)
  • Sampling Diffusion
  • Display 3½ Digit LCD Display with low battery display
  • Hi & Lo Alarm View Keys To view the alarm set-points
  • Electronic Alarm 85 db Audio Alarm, Visual LEDs
  • Battery life Approx. 100 hrs
  • Operating Temperature Range 0 to +50 °C
  • Operating Pressure Ambient +/- 10%
  • Enclosure ABS
  • Weight 230 grams
  • Standard Accessories Carrying Case & Screw driver
  • Dimension H × W × D: 175 × 85 × 30 mm

Portable Gas Detector is a simple and compact instrument, designed to protect personnel from the hazards of toxic and combustible gases. A certified and affordable solution ideal for a wide range of applications.It is available in single gas monitor as well as multi gas monitor. In multi gas monitor it measures upto 4 gases simultaneously.In Multi Gas Detector it will detect LEL, O2, H2S, CO simultaneously.

FEATURES:
High specificity to gas of concern.Long sensor life.Quick response.Continuous display of the gas concentration reading.Built-in audible and visual alarms.Easy to read LCD display.


GAS DETECTED:
Carbon Monoxide, Flammable, O2, Bromine, Chlorine, Diborane, Formaldehyde, H2, HCL, Carbon disulphide, HCN, HF, Hydrazine, Hydrogen Sulphide, NH3, NO2, Vinyl Chloride, Ethyl Mercaptan, Phosphine, Sulpher dioxide, Ammonia, Silane, Phosgene, VOC.

APPLICATIONS:
Confined SpacesFumigationOccupational Safety & HealthOil & GasPetrochemical PlantsProcess ControlResearch Laboratories
View Complete Details

Fixed Gas Detector

  • Flamable Catalytic Bead Detector / Non Dispersive InfraRed Detector (NDIR)
  • Toxic Electrochemical
  • VOC       Photo  ionization Detector (PID)
  • Dimension 230MM*220MM*120MM, Weight-2.5 Kg (Approx)
  • Enclosure & Mounting Flame proof, Cast Aluminum Alloy. Mounting on walls or poles or similar support
  • Operating Voltage & Power 18 to 28 VDC (Typically 24 VDC), Power-Less than 3 Watt.
  • Operating Temp -20 to 50 degree C
  • Operating Pressure & Humidity Ambient +/-10% and  0-95% RH (Non Condensing)
  • Output 4-20 mA and RS-485 (MOD-BUS)
  • Standards complied IS/IEC:60079-0:2004 IS/IEC:60079-1:2007 IP-IS/2063-1987(IEC60529:2001)
  • Certification CCOE & CIMER certified to Exd IIC, T6, IP66 (Cat No-UJB20130) ATEXExII2GExdIICT6GbTamb-20 degree C to + 40 degree C, in process.

Digital Universal Gas Transmitter is a field mounted gas detector for the continuous monitoring of hazardous & combustible gases. It provides an industry standard 4-20 mA output signal that can be connected to any control system (DCS, PLC, etc.). It also provides RS-485 MODBUS-RTU digital output signal. It is available for a large variety of toxic and flammable gases such as Combustibles, Oxygen, Carbon Monoxide, Hydrogen Sulfide, Ammonia, Chlorine, SO2, NH3, HCN, HCL, NO2 etc


APPLICATIONS:
  • Refineries
  • Petrochemicals
  • Pharmaceuticals
  • Power Industries
  • Pollution control monitoring
  • Oil & Gas Industry.

View Complete Details

Flammable Gas Leak Detector

  • Detector Heads & Alarm Indicator Console Each console can handle up to 10 detector heads
  • Display Power ON Indicator LED for each detector head.
  • Function Keys      Membrane switch for alarm acknowledgement & mute
  • Alarms Visual & 107dB Audio Hooter Alarm at Alarm Indicator Consoles. Visual flashing LEDs on detector heads
  • Relay Output Potential Free SPDT relay contact provision at local and remote Alarm Indicator Consoles
  • Power supply 230 VAC, 50 Hz mains supply (SMPS) for digital receivers
  • Self Test Pre-programmed 'self test' checks sensor integrity, alarm functions and system functioning
  • Size Detector heads: 110 mm diameter

Flammable Gas Monitoring System is a novel state of the art leak detection system. Designed for permanent installation, the unit is able to monitor the presence of combustible gases such as LPG, CNG, LNG etc. in a variety of applications.

FEATURES:
Microprocessor based system with in-built self-test facility & RS 485 digital data communication link.
CMRI / CCOE certified Gas Leak Detector heads continuously monitors the presence of flammable gases.
Local & an optional Remote Alarm Indicator console provides audio-visual alarm status from all detector heads.
Relay output for automatic activation of exhaust fan, hooter, solenoid valve etc.
Alarm acknowledgement / reset and mute keys on both local and remote consoles.

APPLICATIONS:

  • LPG/CNG/LNG
  • Gas storage area
  • LPG Bullet & Banks
  • Plant Locations
  • Hotel Kitchens
  • Industrial Canteens
  • Gas Filling Stations
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Websoft Solution (Websoft Solution)
  • 83/65 RASHKHOLA ROAD, KHARDAH , Khardaha, Kolkata, West Bengal - 700117, India
  • Share us via