Our Product / Services
Scientific Instruments
2 Products availableMeasuring Instruments
1 Products availableFilters
1 Products availableCalipers
1 Products availableLevel Switches
1 Products availableDecorative Lights, Lamps & Lamp Shades
1 Products availablePressure Switches
1 Products availableOur product range contains a wide range of Analog Pressure Gauge, Ultrasonic Thickness Gauge and Differential Pressure Gauge Magnehelic Gauge
Application: Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc.
Measuring range (metric/imperial): 1.2-225mm, 0.05-8inch
Materials measured: any hard materials, including steel, cast iron, aluminum, red copper, brass, zinc, quartz glass,
polyethylene, PVC, gray cast iron, nodular cast iron and other materials
Sound velocity: 500-9000m/s
Lower limit steel pipes: 15x2.0mm, 20x3.0mm determined by the transducer
Calibration block: included , Resolution: 0.1mm , Accuracy: ± (0.5%n+0.1)
RS232C interface port provided , Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator , Operating conditions:0-+45C (32F -104F), ≤90%RH
Accessories : Instructional Manual, Glycerine , Batteries
Mounting - A single case size is used for most models of Magnehelic® gages. They can be flush or surface mounted with standard hardware supplied. Although calibrated for vertical position, many ranges above may be used at any angle by simply rezeroing. However, for maximum accuracy, they must be calibrated in the same position in which they are used. These characteristics make Magnehelic® gages ideal for both stationary and portable applications. A 4-9/16 hole is required for flush panel mounting. Complete mounting and connection fittings, plus instructions, are furnished with each instrument
Specifications :
Graph
Range
| Model | Range Inches of water |
|---|---|
| 2000-00N†•• | .05-0-.2 |
| 2000-00†•• | 0-.25 |
| 2000-0†• | 0-.50 |
| 2001 | 0-1.0 |
| 2002 | 0-2.0 |
| 2003 | 0-3.0 |
| 2004 | 0-4.0 |
| 2005 | 0-5.0 |
| 2006 | 0-6.0 |
| 2008 | 0-8.0 |
| 2010 | 0-10 |
| 2012 | 0-12 |
| 2015 | 0-15 |
| 2020 | 0-20 |
| 2025 | 0-25 |
| 2030 | 0-30 |
| 2040 | 0-40 |
| 2050 | 0-50 |
| 2060 | 0-60 |
| 2080 | 0-80 |
| 2100 | 0-100 |
| 2120 | 0-120 |
| 2150 | 0-150 |
| 2160 | 0-160 |
| 2180* | 0-180 |
| 2250* | 0-250 |
| Zero Center Range | |
| 2300-00†•• | 0.125-0-0.125 |
| 2300-0†• | .25-0-.25 |
| 2301 | .5-0-.5 |
| 2302 | 1-0-1 |
| 2304 | 2-0-2 |
| 2310 | 5-0-5 |
| 2320 | 10-0-10 |
| 2330 | 15-0-15 |
| Model | Range PSI |
| 2201 | 0-1 |
| 2202 | 0-2 |
| 2203 | 0-3 |
| 2204 | 0-4 |
| 2205 | 0-5 |
| 2210* | 0-10 |
| 2215* | 0-15 |
| 2220* | 0-20 |
| 2230** | 0-30 |
| Model | Range CM of Water |
| 2000-15CM | 0-15 |
| 2000-20CM | 0-20 |
| 2000-25CM | 0-25 |
| 2000-50CM | 0-50 |
| 2000-80CM | 0-80 |
| 2000-100CM | 0-100 |
| 2000-150CM | 0-150 |
| 2000-200CM | 0-200 |
| 2000-250CM | 0-250 |
| 2000-300CM | 0-300 |
| Zero Center Range | |
| 2300-4CM | 2-0-2 |
| 2300-10CM | 5-0-5 |
| 2300-30CM | 15-0-15 |
| Model | Range MM of water |
| 2000-6MM†•• | 0-6 |
| 2000-10MM†• | 0-10 |
| 2000-15MM | 0-15 |
| 2000-25MM | 0-25 |
| 2000-30MM | 0-30 |
| 2000-50MM | 0-50 |
| 2000-80MM | 0-80 |
| 2000-100MM | 0-100 |
| 2000-125MM | 0-125 |
| 2000-150MM | 0-150 |
| 2000-200MM | 0-200 |
| 2000-250MM | 0-250 |
| 2000-300MM | 0-300 |
| Zero Center Range | |
| 2300-6MM†•• | 3-0-3 |
| 2300-10MM†• | 5-0-5 |
| 2300-20MM†• | 10-0-10 |
| Model | Range, Pa |
| 2000-60NPA†•• | 10-0-50 |
| 2000-60PA†•• | 0-60 |
| 2000-100PA†• | 0-100 |
| 2000-125PA†• | 0-125 |
| 2000-250PA | 0-250 |
| 2000-300PA | 0-300 |
| 2000-500PA | 0-500 |
| 2000-750PA | 0-750 |
| 2000-1000PA | 0-1000 |
| Zero Center Ranges | |
| Model | Range, Pa |
| 2300-60PA†•• | 30-0-30 |
| 2300-100PA†• | 50-0-50 |
| 2300-120PA | 60-0-60 |
| 2300-200PA | 100-0-100 |
| 2300-250PA | 125-0-125 |
| 2300-300PA | 150-0-150 |
| 2300-500PA | 250-0-250 |
| 2300-1000PA | 500-0-500 |
| Model | Range, kPa |
| 2000-0.5KPA | 0-0.5 |
| 2000-1KPA | 0-1 |
| 2000-1.5KPA | 0-1.5 |
| 2000-2KPA | 0-2 |
| 2000-2.5KPA | 0-2.5 |
| 2000-3KPA | 0-3 |
| 2000-4KPA | 0-4 |
| 2000-5KPA | 0-5 |
| 2000-8KPA | 0-8 |
| 2000-10KPA | 0-10 |
| 2000-15KPA | 0-15 |
| 2000-20KPA | 0-20 |
| 2000-25KPA | 0-25 |
| 2000-30KPA | 0-30 |
| Zero Center Ranges | |
| 2300-1KPA | .5-0-.5 |
| 2300-2KPA | 1-0-1 |
| 2300-2.5KPA | 1.25-0-1.25 |
| 2300-3KPA | 1.5-0-1.5 |
Dual Scale Air Velocity Units
| Model | Range in W.C./ Velocity F.P.M. |
|---|---|
| 2000-00AV†•• | 0-.25/300-2000 |
| 2000-0AV†• | 0-.50/500-2800 |
| 2001AV | 0-1.0/500-4000 |
| 2002AV | 0-2.0/1000-5600 |
| 2005AV | 0-5.0/2000-8800 |
| 2010AV | 0-10/2000-12500 |
Dual Scale English/Metric Models
| Model | Range, in w.c. | Range, Pa or kPa |
|---|---|---|
| 2000-00D†•• | 0-.25 | 0-62 Pa |
| 2000-0D†• | 0-0.5 | 0-125 Pa |
| 2001D | 0-1.0 | 0-250 Pa |
| 2002D | 0-2.0 | 0-500 Pa |
| 2003D | 0-3.0 | 0-750 Pa |
| 2004D | 0-4.0 | 0-1.0 kPa |
| 2005D | 0-5.0 | 0-1.25 kPa |
| 2006D | 0-6.0 | 0-1.5 kPa |
| 2008D | 0-8.0 | 0-2.0 kPa |
| 2010D | 0-10 | 0-2.5 kPa |
| 2015D | 0-15 | 0-3.7 kPa |
| 2020D | 0-20 | 0-5 kPa |
| 2025D | 0-25 | 0-6.2 kPa |
| 2050D | 0-50 | 0-12.4 kPa |
| 2060D | 0-60 | 0-15 kPa |