Electrolytic Grade Connectors

  • TEST A.C. Dry withstand Voltage , Impulse voltage test and DC High Voltage
  • Type XSSS 72 114 kV / 4 Hrs. , 325 kV / 10 Shots and 114 kV / 15 Min.
In house state-of-art compounding technology to provide maximum protection against tacking, corona discharge & dielectric stress.Minimises jointers skills.The Products are carefully selected compositions of raw materials to meet the most stringent demandsWe also offer tailor-made solutions against specific requirements.Continuous operation temperature-550C to 1200C.Corrosion resistant and unlimited shelf life.High resistance to impact and abrasion.Electrolytic grade connectors.
View Complete Details

Heat Shrink Straight Joint Kit

  • TESTING ITEMS U °/U A/C withstand test , Partial discharge test and Thermal Cycles (63 cycles)
  • 6.35/11 kV 29kV, 5min, no flashover , 11kV<10pc (Max.) and under95-100o C 16kV
  • 12.7/22 kV 58kV, 5min, no flashover , 22kV<10pc (Max.) and under95-100o C 32kV
  • 19/33 kV 86kV, 5min, no flashover , 33kV<10pc (Max.) and under95-100o C 48kV
In house state-of-art compounding technology to provide maximum protection against tacking, corona discharge & dielectric stress.Minimises jointers skills.The Products are carefully selected compositions of raw materials to meet the most stringent demandsWe also offer tailor-made solutions against specific requirements.Continuous operation temperature-550C to 1200C.Corrosion resistant and unlimited shelf life.High resistance to impact and abrasion.Electrolytic grade connectors.
View Complete Details

36kv Cold Shrink Straight Through Joints

  • TESTING ITEMS U °/U 50 Hz Voltage test , Partial discharge test and Cyclic load test, 3 cycles
  • TYPE 8.7/ 15 KV 39 kV, 5min, no flashover, no strite , 15 kV < 1pc and 3 cycles under 90-95°C, 22kV
Simple structure, light in weight, single body joint reduction jointers expertise, easy to install.Anti- Tracking high electrical strength, unlimited shelf life. Resistance to weather, UV light and salt pollution, no explosion and fire hazard.The products are carefully selected compositions of raw materials to meet the most stringent demands and compliance to various international specifications and standards. Pre-engineeredinbuilt stress cone offering high stress control properties.
View Complete Details

Densons Cold Shrink Straight Through Joints Upto 36 KV For XLPE Cable With Armour Tape

  • TESTING ITEMS U °/U 50 Hz Voltage test , Partial discharge test
  • TYPE 8.7/ 15 KV 39 kV, 5min, no flashover, no strite , 15 kV < 1pc
Simple structure, light in weight, single body joint reduction jointers expertise, easy to install. Anti- Tracking high electrical strength, unlimited shelf life.Resistance to weather, UV light and salt pollution, no explosion and fire hazard. The products are carefully selected compositions of raw materials to meet the most stringent demands and compliance to various international specifications and standards.Pre-engineeredinbuilt stress cone offering high stress control properties.
View Complete Details

Heat Shrinkable Terminations

  • Testing Items U o/U A.C. Dry withstand Voltage , Impulse voltage test and DC High Voltage
  • Type XS-OS/ES 72 114 kV / 4 Hrs. , 325 kV / 10 Shots and 114 kV / 15 Min.
In house state-of-art compounding technology to provide maximum protection against tacking, corona discharge & dielectric stress. Minimises jointers skills.The Products are carefully selected compositions of raw materials to meet the most stringent demands. We also offer tailor-made solutions against specific requirements.Continuous operation temperature-550 C to 1200 C.Corrosion resistant and unlimited shelf life. High resistance to impact and abrasion. Electrolytic grade connectors.
View Complete Details

Heat Shrink Terminations Upto 36 KV

  • TEST TEST , A.C. Voltage withstand , D.C. Voltage withstand and Impulse Voltage withstand (10+VE & 10-VE Shots)
  • TYPE PSO/E - 2236 TYPE PSO/E - 2236 , Dry: A.C.75 kV / 1 min. Wet A.C. 75 kV / 1 min. , 144kV for 30 min. and 170
Heat Shrink Terminations upto 36 kV DENSONS HEAT SHRINKABLE TERMINATIONS UPTO 36 kV For 3 Core 'H' Type Cable
View Complete Details

Terminations Upto 36 KV For Single Core XLPE/EPR Insulated

  • TEST A.C. Dry withstand Voltage , Impulse withstand Voltage
  • TYPE XSO/E - 2236 75 kV / 1min , 170 kV / 10 shots
Terminations upto 36 kV For Single Core XLPEEPR Insulated DENSONS HEAT SHRINKABLE TERMINATIONS UPTO 36 kV For Single Core XLPEEPR Insulated Cable
View Complete Details

Medium Voltage Conductor Cover

  • Property Tensile strength , Elongation at Break and Dielectric strength
  • Typical Data ≥N/mm2 , ≥ 500% and ≥ 20kV/mm
Medium Voltage Conductor Cover Live Installation Anti-tracking LightweightSuperior UV and Abrasion Resistance Weather Resistance Range Taking Quick InstallationLocalized Installation
View Complete Details

Heat Shrinkable Low Voltage Insulating Breakout

  • Property Tensile strength , Ultimate Elongation
  • Requirements 8N/mm2 (min.) , 200% (min.)
  • Test Method ASTM D412 , ASTM D412
Application : sealing spreader caps for all indoor & outdoor application of polymeric insulated cablesmaterial : cross linked polyolefin, free of lead & cadmiumcolour : blackoutstanding mechanical, chemical & electrical propertiesuv- resistanthalogen - freethermoplastic adhesive liner provides complete enviromental pressure &humidity protectioncontinuous operation temperature: - 55 c to 120 cseals and protects multi - conductor cable and conduit breakoutsin conformance with esi 09 - 13.
View Complete Details

Heat Shrinkable Busbar Insulation Tape

  • Property Tensile strength ., Tensile strength after aging
  • Requirements 8 N/mm2 (min) , 7N/mm2 (min.)
  • Test Method ASTM D 638 , ASTM D 2671/120oC , 168 hrs.
DBIT is made from radiation cross linked polyolefinThe dual layer structure of insulationhot melt adhesiveWidely used to protect complex busbar connections where tube products can not be appliedUp to 24 KV
View Complete Details

Heat Shrinkable Cable End Caps

  • Property Tensile strength , Ultimate Elongation and Continuous Operating Temperature
  • Requirements 8N/mm2 (min .) , 200% (min.) and -55o C to 120o C
  • Test Method ASTM D 412/ISO 37 , ASTM D 412 / ISO 37 and 216
Effectively offering protection against oxidation, ozone, UV radiation etcCoated with hot melt adhesive to ensure environment sealEasily to fit over the cable endProtect power cable up to 1000V and telecommunication cableMaterial: Thermally stabilized cross-linked polyolefin, coated with specially designed hot melt adhesiveMinimum fully shrink temperature:120 oC
View Complete Details

Heat Shrinkable Semi Conductive Breakout

  • Property Tensile strength , Elongation at break and Water absorption
  • Requirements 8 N/mm (min.) , 200% (min.) and 0.5% (max.)
  • Test Method ASTM D 638 , ASTM D 638 and ISO 62
Breakout can be used to cable terminations up to 36 KVThe electrically semi-conductive breakout provide effective conductive screen and sealing protection to the cable terminationMinimum fully recovered temperature:130oC
View Complete Details

Heat Shrinkable Anti Tracking Straight Boot

  • Property Tensile Strength , Elongation
  • Requirements 8N/mm2 (min.) , 200% (min)
  • Test Method ASTMD 412, ESI09-13 , ASTMD 412, ESI09-13
Designed for medium voltage applications up to 36 KVShaped components to meet a variety of configuration requriementsContinuous operation temperature: -55 C to 120 CUsed in proctecting cable and up to 36 KV against flashover or surges induce during working life in switch gear in and transformer boxes.
View Complete Details

Heat Shrinkable Insulating Wrap Around Sleeve

  • Property Tensile strength , Ultimate elongation and Continuous Operating Temperature
  • Requirements 8 N/mm2 (min) , 200% (min) and -55o C to 120o C
  • Test Method ASTM D 412/ISO 37 , ASTM D 412 / ISO 37 and IEC 216
Application : Insulating, Pressure & humidity-tight sheathings, Suitable for cable joints & terminationsMaterial : Cross linked polyolefin, free of lead & cadmiumColour : BlackMedium wallHigh Tensile strengthResistant to cold flowVery good chemical & electrical propertiesNon-corrosiveUV-resistantContinuous operation temperature: -55 degrees to 125 degrees centigradeIn conformance with ESI 09 - 13
View Complete Details

Heat Shrinkable Anti Tracking Right Angle Boot

  • Property Tensile Strength , Elongation
  • Requirements 8N/mm2 (min.) , 200% (min)
  • Test Method ASTM D412, ESI 09-13 , ASTM D412, ESI 09-13
Designed for medium voltage applications up to 36 KVShaped components to meet a variety of configuration requriementsContinuous operation temperature: -55 C to 120 CUsed in proctecting cable and up to 36 KV against flashover or surges induce during working life in switch gear in and transformer boxes.
View Complete Details

Heat Shrinkable Anti Tracking Breakout

  • Property Tensile Strength , Elongation
  • Requirements 8N/mm2 (min.) , 200% (min)
  • Test Method ASTM D412, ESI 09-13 and ASTM D412, ESI 09-13
Designed for medium voltage applications up to 36 KV Shaped components to meet a variety of configuration requriementsContinuous operation temperature: -55 C to 120 C
View Complete Details

Fiber Reinforced Polymer(FRP) Cross Arms

  • Length 1150 mm (as per REC specifications)
  • FRP Section Used 45 x 75 x 3.5 mm ( box section)
  • Clamping holes 18 mm dia spaced at 200 mm c/c
  • Holes for pin insulators 22 mm dia spaced at 1070 mm c/c passed REC
  • Mechanical strength Specification in X and Y direction at 300 and 100 Kgs.
Weather resistant specially for coastal areasLight weight for easy installation in hilly areasAvoidance of birdage problemContinuance of power supply even after insulators are crackedLower size insulators can be used reducing the cost of insulators
View Complete Details

Outdoor Porcelain Clad Vacuum Circuit Breaker

  • Properties Rated voltage and insulation , Rated current
  • Requirements 12 kV , 630 A/800 A/1250 A
  • Requirements 36 kV , 8000 A/1250 A/1600 A
User friendly and compact design. Poles are Hermetically sealed. Highly reliable & safe to operate. Minimum maintenance. No fire hazards.Suitable for auto re-closing duty. IP-55 degree of protection.
View Complete Details

12 KV Metal-clad Indoor Vacuum Circuit Breaker

  • Properties Rated voltage and insulation , Rated maximum current of the feeders
  • Requirements 12 kV , 2000 A
Sheet Metal Enclosure-Pre-treated & Powder CoatedBolted ConstructionExtendable from both sides of penalPVC Insulated BusbarNo live parts accessible & exposedIn-built safety shutterAll Switching operations performed with front door closedCircuit Breaker withdraw type with interlock & fixed typeSeparate compartment for Breaker, Busbar, CTCable & Instrument chamberAccess to cable terminals from the rear
View Complete Details

Lightning Arresters

  • PARAMETERS HIGHEST SYSTEM VOLTAGE ., RATED FREQUENCY
  • 11 kV 12kV(r.m.s) , 50Hz
  • 22 kV 24kV(r.m.s) , 50Hz
  • 33kV 36kV(r.m.s) , 50Hz
A lightning arrester Surge Arrester is a device used on electrical power systems to protect the insulation of transformer and conductors of the system from the damaging effects of lightning. The typical lightning surge arrester has a high-voltage terminal and a ground terminal. When a lightning surge (or switching surge, which is very similar) travels along the power line to the arrester, the current from the surge is diverted through the arrestor, in to earth.
View Complete Details

Polymeric Drop Out Fuse

  • PARAMETERS SYSTEM VOLTAGE , HEIGHT SYSTEM VOLTAGE
  • 11 kV 11kV(r.m.s) , 12kV(r.m.s)
Our Drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution system for protection of H. T. lines and transformer centers Tap lines.
View Complete Details

Polymeric Goab Switch

  • PARAMETERS SYSTEM VOLTAGE , HEIGHT SYSTEM VOLTAGE
  • 11 kV 11kV(r.m.s) , 12kV(r.m.s)
  • 22 kV 22kV(r.m.s) , 24kV(r.m.s)
  • 33 kV 33kV(r.m.s) , 36kV(r.m.s)
The Polymer Air Break Switch is gang operated and outdoor Type. The main Application of this product is to isolate the Transformer, Overhead lines, System or Cables from distribution network.
View Complete Details

Composite Insulators

  • Nominal System Voltage kV 11 , 11-15 , 11-15
  • Sectional Length in mm 260 , 290 , 320
  • Specified Mechanical in KN (min.) 5 , 45 , 70-90
  • Creepage Distance in mm 320 , 320 , 320
Light weight (65-80% less than ceramic insulator)Silicon rubber sheds provide perfect hydrophobic performance, good resistance to ageing, tracking and erosionStable behaviour at extreme climatic conditionsLong term surface hydrophobicitySuitable for polluted environment, salty atmospheres etc.Resistance to breakage and vandalism, practically unbreakableSuperior anti-tracking propertiesHigh mechanical strengthEase of installation (easier handling with lighter equipment and labour at the job site)Resistance to Seismic ShockCompliance with IEC 61109, ANS C29-11-1989