Measuring Instruments & Equipment

Leading Manufacturer, Supplier & Retailer of Wire Low Resistance, Digital Resistance Meter, Time Interval Meter and Digital Panel Meters.

Wire Low Resistance

  • Make Zeal
  • Model ZMLRJ
  • Maximum Test currents For 10µΩ, 50µΩ, 20 A
  • For 100µΩ to 10mΩ 10 A
  • For 100mΩ 1A
  • For 1000mΩ 100 mA
  • Accuracy 0.25% for 10µΩ, 50µΩ, 0.1% for 100µΩ, 1mΩ, 10mΩ, 100mΩ, 1000mΩ

Low Resistance Meters e.g. Micro Ohm Meter, Milli Ohm Meter work with the principle of 4 wire measurement. Two terminals provide test current and two terminals a re used for sensing voltage drop. It is very difficult to buy Low Resistance standards at affordable prices. ZEAL make, 4 Wire Low Resistance Standard serves the purpose of accuracy and economy. The resistance values are very stable over years. Low resistors of values of 10µΩ, 50µΩ, 100µΩ, 1mΩ, 10mΩ, 100mΩ, 1Ω have been fitted in an enclosure with provision for each resistor’s current terminals and drop terminals.  

View Complete Details

Digital Resistance Meter

  • Power 230V AC, 50Hz, ± 10%
  • Model ZMDRM-10k  
  •    
  • Range 0 to 10 kΩ
  • Maximum Test current 1 mA
  • Indication LED indicator for Low, high and normal (within specification) resistance value.
  • Settings knobs shall be provided to set acceptable Low and High value of resistance.
  • Display Digital, 3½ digit
  • Accuracy 1.5% ± 3 digit
  • Potential free contact will be operated when i/p resistance value is not within acceptable Low or High (out of specification).

ZEAL make resistance meter is used to measure & sort resistances of winding of motors, alternators, transformers etc. Operator can set upper and lower limits of acceptance using the potentiometers on the panel. LEDs are there to indicate if the measurement is within acceptable limit or not. The product is very reliable and cost effective.

View Complete Details

Time Interval Meter

  • Accuracy 30 µs
  • Resolution 1 µs

Make: ZEAL, Model: ZMTIM Input Voltage : 230V50 Hz AC (Supply Voltage) Test conditions: For both START and STOP (By selector switches) 1. Apply DC voltage (upto 24V Max) 2. Apply ground 3. Closure of contact 4. Opening of contact Display: 1. Display-16x2 LCD display 2. With Minutes (30 mins max) Miiliseconds(999ms) Microsecond(999µs)

View Complete Details