Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Biomedical waste sterilizer

Listing ID #4896369

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Model : TSQ-23098-TKS 50 Kg/Hr Automatic Double-doors; built-in Steam Generator Application Range: The sterilizer is used for the sterilizing the clothes, apparatus, vessels, culture medium, small....
View More Details
Send Enquiry

Company Information

  • Member Since 13 Years
  • Nature of Business Retailer
  • Year of Establishment 2000

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Model : TSQ-23098-TKS 50 Kg/Hr Automatic Double-doors; built-in Steam Generator

Application Range:

The sterilizer is used for the sterilizing the clothes, apparatus, vessels, culture medium, small amount of liquid in the unsealed bottles.

Quality System:

The sterilizer is strictly designed and manufactured according to ISO 9001-2000 and ISO 13485-2003 quality system. It is implemented by International relative standard. The sterilizer conforms to the CE standard. The performance is stable and the quality is reliable.

Safety System:

The sterilizer has the multiple safety structures, including overpressure protection, low water-level protection, door interlocking system, electric appliance overloading and short circuit protection, which ensure the safety operation.

Heat Emissions Protection:

The sterilizer’s chamber is covered with mineral wool to protect the heat emission.

    • Chamber

The chamber is made of 304 stainless steel. It is designed and manufactured by the International standard and is checked by national technical inspection department in India The sterilizer is firm and durable.

The inner surface of the chamber is finely polished, glabrous, corrosion-proof and easy for cleaning.

The equipment has over-pressure safety device, which is safe and reliable.

    • Door Structure
    • The sterilizer is automatic operated door structure. The door is open and closed by motors. It is made of SS304.

 

The door of the sterilizer is pressured-air sealed.

Double-door Structure.It has double-door safety interlocking system. When the door is not closed, then steam can not enter the chamber. When the steam pressure in the chamber is more than 0.027MPa, the door cannot open. The front door and the back door can not open at the same time.

The controlling system is mainly composed of PLC from Mitsubishi. The whole system operates reliably and controls preciously, which ensure the overall performance and the sterilizing effect.

The controlling system has HMI, which has the functions including multiple sterilizing processes for users to choose, setting the sterilizing parameters, displaying the parameters and the cycle phases, printing the sterilizing reports and the compelling hand operation.

 

The micro printer is used for recording and printing the key parameters of time, temperature and the pressure in the operation process, which is easy for the users to file and analyze technically.

 

The micro printer is used for recording and printing the key parameters of time, temperature and the pressure in the operation process, which is easy for the users to file and analyze technically.

The vacuum system of the sterilizer is mainly composed of liquid ring vacuum pump, vacuum valve and the interconnecting pipelines. Among these, the vacuum pump is the key part. The vacuum system has good advantages of operating stably, low voice, high vacuum and quick air suction speed, which ensures the sterilizing effect and the whole performance.

It is used for sterilizing the less amount of liquid in the unsealed bottles and culture medium. The sterilizing program is composed of warming-up, rising temperature and sterilizing (keeping the same temperature for a certain time) and cooling. The users can set the sterilizing parameters according to the goods’ characteristics and the manufacturing requirements. The setting range of the sterilizing parameters is: Sterilizing Pressure: 0.07-0.22Mpa; Sterilizing Temperature: 115-134℃;Sterilizing Time: 1-99minutes.

 


Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Biomedical waste sterilizer?

Quantity
Seller Contact Details
  • Seller Acmas Technologies (pvt.) Ltd.
  • Address Kundli, Kundli, Haryana

Find similar products

View all products in Sterilizers
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Biomedical waste sterilizer at Best Price in Kundli - ID: 4896369 | Acmas Technologies (pvt.) Ltd.
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Biomedical waste sterilizer

Listing ID #4896369

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Model : TSQ-23098-TKS 50 Kg/Hr Automatic Double-doors; built-in Steam Generator Application Range: The sterilizer is used for the sterilizing the clothes, apparatus, vessels, culture medium, small....
View More Details
Send Enquiry

Company Information

  • Member Since 13 Years
  • Nature of Business Retailer
  • Year of Establishment 2000

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Model : TSQ-23098-TKS 50 Kg/Hr Automatic Double-doors; built-in Steam Generator

Application Range:

The sterilizer is used for the sterilizing the clothes, apparatus, vessels, culture medium, small amount of liquid in the unsealed bottles.

Quality System:

The sterilizer is strictly designed and manufactured according to ISO 9001-2000 and ISO 13485-2003 quality system. It is implemented by International relative standard. The sterilizer conforms to the CE standard. The performance is stable and the quality is reliable.

Safety System:

The sterilizer has the multiple safety structures, including overpressure protection, low water-level protection, door interlocking system, electric appliance overloading and short circuit protection, which ensure the safety operation.

Heat Emissions Protection:

The sterilizer’s chamber is covered with mineral wool to protect the heat emission.

    • Chamber

The chamber is made of 304 stainless steel. It is designed and manufactured by the International standard and is checked by national technical inspection department in India The sterilizer is firm and durable.

The inner surface of the chamber is finely polished, glabrous, corrosion-proof and easy for cleaning.

The equipment has over-pressure safety device, which is safe and reliable.

    • Door Structure
    • The sterilizer is automatic operated door structure. The door is open and closed by motors. It is made of SS304.

 

The door of the sterilizer is pressured-air sealed.

Double-door Structure.It has double-door safety interlocking system. When the door is not closed, then steam can not enter the chamber. When the steam pressure in the chamber is more than 0.027MPa, the door cannot open. The front door and the back door can not open at the same time.

The controlling system is mainly composed of PLC from Mitsubishi. The whole system operates reliably and controls preciously, which ensure the overall performance and the sterilizing effect.

The controlling system has HMI, which has the functions including multiple sterilizing processes for users to choose, setting the sterilizing parameters, displaying the parameters and the cycle phases, printing the sterilizing reports and the compelling hand operation.

 

The micro printer is used for recording and printing the key parameters of time, temperature and the pressure in the operation process, which is easy for the users to file and analyze technically.

 

The micro printer is used for recording and printing the key parameters of time, temperature and the pressure in the operation process, which is easy for the users to file and analyze technically.

The vacuum system of the sterilizer is mainly composed of liquid ring vacuum pump, vacuum valve and the interconnecting pipelines. Among these, the vacuum pump is the key part. The vacuum system has good advantages of operating stably, low voice, high vacuum and quick air suction speed, which ensures the sterilizing effect and the whole performance.

It is used for sterilizing the less amount of liquid in the unsealed bottles and culture medium. The sterilizing program is composed of warming-up, rising temperature and sterilizing (keeping the same temperature for a certain time) and cooling. The users can set the sterilizing parameters according to the goods’ characteristics and the manufacturing requirements. The setting range of the sterilizing parameters is: Sterilizing Pressure: 0.07-0.22Mpa; Sterilizing Temperature: 115-134℃;Sterilizing Time: 1-99minutes.

 


Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Biomedical waste sterilizer?

Quantity
Seller Contact Details
  • Seller Acmas Technologies (pvt.) Ltd.
  • Address Kundli, Kundli, Haryana
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice