Our Products
Chrometography
2 Products availableBiochemistry Analyzer
2 Products availableChromatographic Analyzer
2 Products availableWoodworking Tools And Machines
1 Products availableBio Medical
1 Products availableAnalyzers And Analytical Instruments
1 Products availableOur Complete range of products are Microprocessor Flame Photometer 2382, X-RAY DIFFRACTION ANALYZER, X-Ray General Purpose Diffractometer 3700 Series, Differential Scanning Calorimeter DSC 3100 and Toc Analyzer.
| Technical Specification | |||
| MICROPROCESSOR FLAME PHOTOMETER, MODEL 2382 is an ideal instrument for the determination of Sodium, Potassium, Calcium and Lithium. It uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. It has soft touch membrane keys for ease of operation. The solution is aspirated through an atomiser. Air, sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. | |||
| Features | The 5 point calibration facility and non-linearity correction is provided through an automatic curve fitting software. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of multiple standards once a calibration has been performed. | ||
| Technical Specification | |||
| XRD 3010 mainly used for the phase characterization, quantitative analysis, crystal structure, material structure, crystal orientation, macroscopic and microscopic stress determination, crystal size, crystallinity determination, etc. By the principle of Scherrer, High precision is assured. Widely used in geology, oceanology, biology, chemistry, nuclear station research as well as industrial and institute research. | |||
Operation Requirements :
Installation Requirements
Equipment Voltage
Cooling Water :
X-ray diffraction is the dactyloscopy in material science , a reliable non-destructive technique of identification of crystalline matter.
Basic comfiguration :
Advance Option :
Main features:
1. The new fully enclosed metal furnace body design structure greatly improves the resolution and resolution and better baseline stability.
2. Using professional alloy sensor, it is more resistant to corrosion and oxidation, and the sensor has high sensitivity.
3. Perfect two-way atmosphere control system, precise control of purge gas flow, automatic switching of software settings, and data directly recorded in the database.
4. Using Cortex-M3 core ARM controller, the calculation processing speed is faster, and the temperature control is more accurate.
5. Using USB two-way communication, the operation is more convenient and supports self-recovery connection function.
6. Using 7-inch 24bit color full-color LCD touch screen, real-time display of the status and data of the instrument.
7. The instrument is equipped with standard materials, and users can calibrate each temperature section by themselves to reduce the error of the instrument.
8. Intelligent software design, automatic drawing of the instrument in the whole process, the software can realize various data processing, such as the calculation of enthalpy, glass transition temperature, oxidation induction period, melting point and crystallization of substances, etc. Measure physical and chemical changes related to heat, such.
Instrument use:
Measure physical and chemical changes related to heat, such as glass transition temperature, melting point, melting temperature, crystallization and crystallization heat, phase transition reaction heat, product thermal stability, solidification/crosslinking, oxidation induction period, etc.
FEATURES:
Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self-testing flow rate control to ensure high performance and safe operation.
Low current system design also ensures operation safety. Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data, outstanding particle handling capability and capable to handle small sample volumes.
Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.
Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instruments safety.
Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data. TOC detector the 24 bits data solution extends monitoring range.
Controlling system with 32bin processing greatly improves performance.
GENERAL:
TOC (Total Organic Carbon), which directly shows the total organic content is regarded as a key factor to evaluate the pollution potential of organic compound in water.
After 3 years research and development, successfully launch our new product: patent laws, our TOC can meet requirements for application in water analysis, environment monitoring, pharmaceutical production, quality control, processing control, etc.
So far launch 2 models TOC-2000 (Catalytic combustion oxidation) (Wet chemical oxidation by UV ) which are widely used for quality control of drinking water, industrial water, sewage and waste water, meanwhile, it has wide application in monitoring of River, Lake, Sea and surface water.
Model: TOC - 2000
Detector: NDIR
Parameter: TC, TIC, TOC.
Digestion Mode: High Temperature combustion
Operation Mode: PC control
Application: Liquid sample, Gas sample, Solid Sample
Gas Requirement: Oxygen /Nitrogen 99.995%
Measurement Range: 50 g/l -30, 000mg/l
Detection Limit: 50 g/l
Repeatability: 3%
Accuracy: 2%
Maximum salinity: 85g/l
Power: AC 220V, 50Hz OR AC 110V, 60Hz
Size: 430455440mm
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
| Technical Specification | |||
| Laser light multi-dimensional cell classificat on Double mode for WBC countion (Impedance Count and Optical Count) Resistant: RBC mode Sample rotatory valve quantification technique Up to 110 samples per hour Walk-away automation, high efficiency and accuracy WBC 5 part diff with sheath reagent only. Semiconductor laser based flow cytometry for WBC Differential with specific staining to stain nucleic acid content of cells which generate fluorescence to differentiate between abnormal cell and normal cells. | |||
| Features | 27 parameters 3 Histograms for RBC, WBC and PLT 2 Scatter grams Sampling modes Auto loader 160L, Manual mode 160L, Pre-diluted mode 40L Auto stop function available Data Storage WBC 100 um, RBC/PLT 80 um Up to 200, 000 sample | ||
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T, Western Union,
Performance index :
1. Model:The 4th generation EDX analyzer XRF series.
2. Analysis method:Energy dispersive X-ray uorescence analysis method.
3. Measuring range of elements: Mg to U.
4. Simultaneously detect elements:Simultaneously detect tens of elements.
5. Processor and RAM:CUP: 667MHz, RAM:256M , Maximum expanded storage: 32G, Standard conguration: 2G , can store large amounts of data.
6. Content range: ppm99.99%.
7. Testing time :3-30 seconds.
8. GPS WIFI:Built-in system.
9. Battery time: Lithium battery, which can be charged, with maximum capacity of 7800mAH, can continuously work for 8 hours; Equiped with wide voltage(110V-220V) general adapter, can work under alternating current.
10. Testing object:Solid, liquid , powder.
11. Detector:25mm2 0.3milSDD detector.
12. Detector resolution: Lowest resolution can be 139eV .
13. Excitation source:40KV/100uA-Ag anode window miniature X light tube and high voltage source.
14. Collimator and filter:Collimator of 4.0 or 2.0 diameter, automatic switch of 6 types filter groups. 12 kinds of groups, worlds most compound mode, can satisfy various kinds of samples testing.
15. Video system:HD camera.
16. Screen :TFT-LCD touch screen, resolution 640*480.
17. Detection limit:Lowest detection limit accounts to ppm level.
18. Testing window:12mm.20.Safety :Self-contained password manager mode.
19. Gas charging system: Helium charging at ordinary pressure system.
20. Data transmission: Digital multi-channel technology, SPI data transmission, quick analysis, high counting rate, waterproof miniature USB, which can be connected to desktop computer
21. Humidity :90%.
22. Temperature: -20 +50.
23. Size :23430682mm LHW .
24. Weight:1.9Kg with battery1.6Kgwithout battery).
3003 XRF The instrument is widely used in toy safety testing, electrical and electronic and RoHS testing etc.