1 Products availableLeading Manufacturer, Supplier & Retailer of Differential Scanning Calorimeter - 3052, BET Surface Area and Pore Size Analyzer SAPSA-3200, CT Scanner and Ion Chromatograph.
| Adopts the single-beam dual-lens system designeHigh accuracy and repeatability: the error of accuracy and repeatability are much less than the allowable error through testing Standard Sample. The error of accuracy and repeatability are all less than 3%, other indexes are up to the International Standard ISO 13321. Features : Fast testing: just spend less than 5 minutes testing sample and getting an accurate result. A precise temperature control system: temperature control precision of 0.2C, to ensure accuracy of test results. High precision photomultiplier(PMT): imported photomultiplier(PMT), high sensitivity, high-speed. stable performance, precise recognition of each photon. High performance photon correlator: adopt photon correlator which developed by large scale integrated circuit (DSP), multichannel, high-speed, identify photon signal of different particle size effectively. Fast testing: just spend 1-3 minutes testing sample and getting an accurate result. A precise temperature control system: temperature control precision of 0.5C, to ensure accuracy of test results. High precision photomultiplier(PMT): imported photomultiplier(PMT), high sensitivity, high-speed, stable performance, precise recognition of each photon. High performance photon correlator: adopt photon correlator which developed by large scale integrated circuit(DSP), multichannel, high-speed, identify photon signal of different particle size effectively. Functional software: user-friendly interface makes operation easily, animation display. The software also has multi-language function, 17 languages switch easily; convert test report into the format of Excel, Word, etc; also the software integrates a test report edit function, provides 12 formats of Chinese and English for users to choose at any time. |
| Technical Specification | |||
| DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DCS research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation, induction time (OIT). | |||
| Features | New designed oven structure ensures high resolution and good stability of base line.Air flow meter may control the air flow rate accurately; the test data can be recorded.It is bilateral control, may be controlled by both main frame and software. | ||
Outline :
The SAPSA 3200 Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.
Features :
Test Module Internal temperature of test module can be controlled through Real-time monitoring, ensuring accuracy of adsorption detection.
Saturated Vapor Pressure P0 Using independent P0 pressure sensor for P0 value by inching test, guarantees the reliability of experimental data. Atmospheric pressure input method to determine P0 also be selected.
Control and Analysis Software :
Software is intelligent software in operation control, data acquisition, calculation and analysis and report generation on the Windows platform. This software can communicate with the host through the LAN port and remotely control many instruments at the same time.
Applications :
1.Material Research :ceramic powder, metal powder, nanotube -According to surface area value of nanotube, hydrogen storage capacity can be predicted.
2.Chemical Engineering:carbon black, amorphous silica, zinc oxide, titanium dioxide -Introduction of carbon black in rubber matrix can improve mechanical properties of rubber products. Surface area of carbon black is one of the important factors affecting the reinforcement performance of rubber products.
3.New Energy :lithium cobalt, lithium manganate -Increasing surface area of electrode can improve Electrochemical reaction rate and promote iron exchange in negative electrode.
4.Catalytic Technologies :active alumina oxide, molecular sieve, zeolite -Active surface area and pore structure influence reaction rate.
| Technical Specification | |||
| TOC-3600 use the flow UV oxidation- Conductivity Detection method to detect the concentration of total organic carbon in de-ionized water, range from 0.1 ppb - 1500 ppb. Has a high sensitivity and accuracy. | |||
| Features | High accuracy , Lower test limit , Simultaneous Determination of conductivity , Conductivity temperature compensation technology , Interface can be connected , Inch touch screen , Data convenient query | ||
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
The 3016 HD is a high-precision, 16-slice CT scanner designed to meet current and future clinical needs. With a focus on precision imaging, low-dose technology, and advanced diagnostic capabilities, it supports accurate detection and treatment planning across multiple clinical applications. The system is seamlessly upgradeable to 64-slice configurations, ensuring long-term adaptability for hospitals and diagnostic centres. Ideal for brain, lung, bone, and body imaging, it combines advanced hardware, software, and imaging technologies for superior clinical confidence and efficiency.
Key Features :
Precision Technology Platform: OptiWave detector, Admir3D iterative reconstruction, dual-energy head imaging, 1024×1024 matrix.
High-Definition Imaging: Targeted organ imaging with a low-dose platform.
Dual-Mode Gantry Tilt: Mechanical ±30°, Digital ±50° for flexible patient positioning.
AccuTechnologies:
AccuHead: Enhanced grey & white matter imaging
AccuLung: High-resolution lung scans at 30–40% of conventional dose
AccuBone: High-resolution bone imaging
AccuBody: Detailed body imaging for small lesion detection
AccuOtica: High-resolution inner ear imaging
Advanced Scan Modes: Scout, Axial, Helical, Cine, Spiral Auto Start, Bolus Tracking, Virtual Endoscopy, CT Angiography
Low-Dose Imaging: Pediatric scan protocols, contrast agent tracking, Adose dose modulation
Fast Reconstruction: Up to 65 frames/sec for real-time image processing
Patient Table: Max weight 205kg, horizontal & vertical movable range, foot pedal control
Computer System: 3.5 GHz CPU, 64GB RAM, 2TB storage, 24’’ LCD monitor, DICOM 3.0 interface
Artefact Suppression: Amast™ metal and Abast™ bone artefact suppression for clearer imaging
Upgradeability: Seamlessly upgradeable to 64 Clarity or 64 Precision CT platforms
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : Wooden crates with shock absorption and anti-static lining
Delivery Time : 2-3 weeks
| Technical Specification | |||
| AAA 3500 is a Innovative compact Combo for NIN Hydrin/ OPA derivetisation designed fo determination of amino acids and biogenic amines.it can be used in the fields of biochemical research, research of human and animal nutrition, medical diagnostics, control of drugs, food and feedstock. AAA 3500 will provide results with maximum accuracy and reproducibility in continuous operation, saving purchasing, operation and maintenance costs. | |||
| Features | Facilitated with High pressure impulse-free pumps, 6 channel Degasser and clarity control software. | ||
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
FEATURES :
GENERAL:
Model: TOC - 2000
Detector: NDIR
Parameter: TC, TIC, TOC.
Digestion Mode: High Temperature combustion.
Operation Mode: PC control.
Application: Liquid sample, Gas sample, Solid Sample.
Gas Requirement: Oxygen /Nitrogen 99.995%.
Measurement Range: 50 g/l -30, 000mg/l
Detection Limit: 50 g/l.
Repeatability: 3%.
Accuracy: 2%.
Maximum salinity: 85g/l.
Power: AC 220V, 50Hz OR AC 110V, 60Hz.
Size: 430455440mm.
CONVENIENT SOFTWARE OPERATION INTERFACE :
Sample measurement processing monitoring
Set different name, concentration and sample volume.
Real-time sample reaction.
On-line AVG and RSD calculation of testing results.
Display and monitoring of sampling
Sampling volume real-time monitoring.
Automatic sample draining monitoring.
Real-time display and monitoring for heating, cooling and furnace temperature.
Auto Switch of sampling and Draining.
Acidification operation by peristaltic pumps.
Scanning Curves :
Samples Curves shows in the same coordinate system for easy reading of repeatability.
Parameter Setting Interface :
Settings for heating and cooling temperature; acidification sampling and draining time; Basic setting for Pump , valve and temperature control.
Press TC Clean, the system will automatically start drain-add Sodium persulfate-Draining - Sampling-Draining.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Seal wash, without degasser, Seal wash, 2 channels degasser, Isocratic Pump, Binary Pump, Quaternary Pump with, integrated degasser, Manual Injector, Autosampler, Semiconductor temp. control, UV-VIS Detector, DAD, ELSD, RID, Fluorescence Detector.
| |||
Additional Information:
Payment Terms : L/C, D/A, D/P,
Product Introduction :
The portable particle counter adopts the counting principle of the light resistance (shading) method specified by the International Hydraulic Standards Commitiee, and is specially used for the rapid detection device of the oil pollution level on the spot. It has the advantages of small size, light weight, fast detection speed, high precision, good repeatability, etc., and can work under harsh conditions such as high temperature and high pressure.
The built-in micro-water sensor and temperature sensor can detect the water content and oil temperature at the same time as the pollution detection. It is suitable for engine oil, gear oil, transformer oil (ie insulating oil), hydraulic oil, lubricating oil, synthetic oil and other oils. It can be widely used in aerospace, petrochemical, transportation, port, iron and steel metallurgy, automobile manufacturing and other fields.
Features :
Adopts the principle of photoresist (shading) method, using high-precision laser sensor, small size, high precision and stable performance.
Suitable for laboratory or on-site testing, and can also be equipped with a pressure reducing device for online high pressure measurement, real-time monitoring of particle pollution in the oil system.
It can be connected to an external pressure chamber to form positive/negative pressure to realize the detection of high-viscosity samples and sample degassing.
Built-in data analysis system, can display the real data of each channel parcle size and automatically determine the sample level.
The pipeline adopts 316L and PTFE materials to meet the testing of various organic solvents and oils.
With volume flushing and duration flushing modes, it is convenient for users to operate and maintain the equipment.
Built-in ISO4406, NAS1638, SAE4059, GJB420A, GJB420B, OCT17216, GB/T14039 and other particle pollution grade standards.
Built-in calibration function, can be calibrated according to GB/T21540, ISO4402, GB/T18854 and other related standards.
Built-in data analysis system, can automatically determine the sample level according to the standard, with automatic data processing and printing functions.
Any alarm level can be set to achieve pollution or cleanliness detection.
Built-in water sensor and temperature sensor.
English input, one-key switching, with preset, input, modification, and storage functions, convenient and quick operation.
Large storage, you can choose to store in the instrument's internal or external storage devices.
Embedded design, high-strength shell, easy to carry, suitable for all kinds of construction machinery.
Technical Parameters :
Light source: A semiconductor laser
Flow rate range: 5-60mL/min
Offline detect sample viscosity: 100cSt, Optional pressure chamber for high viscosity
Online pressure detection: 0.1-0.6MpaOptional pressure reducing device can reach the highest pressure 40Mpa
Particle size range: 1-500mChoose different types of sensors
Connector: USB connector, power connector
Data storage: 1000 sets of data storage space, and support USB storage
Sensitivity: 0.8m or 4m (c)
Limit coincidence error: 40000 grains/ml
Counting volume: 1-999ml
Counting accuracy: error less than10%
Protection level: IP67 (protective box)
Test time interval: 1 second-24 hours
Test sample temperature: 0-800C
Water activity: 0-1aw (0.05aw)
Water content: 0-360ppm (10%)
Working temperature: -20-600C
Power supply: AC 220V10%, 50/60Hz or DC12-40V
Weight: 5.5kg
Volume: 365295170mm
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
The GC Optima-3007i Gas Chromatograph from Analytical Technologies Limited is a high-performance solution for laboratories and industries seeking precision, reliability, and advanced automation. Its modular design supports multiple detectors (FID, TCD, ECD, FPD, NPD, HID, PID, MSD) and injector options, making it versatile for diverse applications including petrochemical testing, pharmaceutical research, food and beverage quality control, and environmental monitoring. The system offers a wide temperature range, electronic flow and pressure control, and remote operation capability, ensuring consistent and accurate results. Compact, energy-efficient, and easy to operate, the GC Optima-3007i reduces downtime and long-term ownership costs, making it the ideal choice for industries that demand powerful analytical control and dependable performance.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Packaging Details : Standard export-quality carton/wooden box with safety protection
Delivery Time : 2-4 weeks
| Technical Specification | |||
| Compact Bench Top Model Perfact H & E Staining for Rourine Application High Specimrn Throughput Minimum Reagent Exposure Easy to clean Simple to operate Highly recommended for Hematology and also for staining of blood Films and Bone marrow spreads etc. | |||
| Features | Compact Bench Top Model, Perfact H & E Staining for Routine Application, High Specimen Throughput, Minimum Reagent Exposure, Easy to clean, Simple to operate, Highly recommended for Hematology and also for staining of blood Films and Bone marrow spreads etc. | ||
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
| Technical Specification | |||
| The DAC (dynamic axial compression) column adopts latest design by ATL. The piston of column always produce a stable pressure on packing bed which can effectively prevent the collapse and loose of the column bed. | |||
| Features | Short length, Large inner diameter, Pancake shaped. It is far shorter than the open column which length is always more than 1m. Besides, its inner diameter is 10mm to 1000mm.The separation cycle of the pure material will be shorter and the yield will be higher. | ||
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T