Our Products
Our offered Product range includes Laboratory Filters, PES SYRINGE FILTERS - STERILE, MEMBRANE FILTERS PES, GF/3F- 1.2m GLASS FIBRE FILTERS and GLASS FIBRE FILTERS GF/5F -0.7m.
Low protein binding to minimize sample lossWide chemical compatibilityLow sample absorption
Applications :For Analytical and Research applications.Recommended for aqueous as well as organic solvent filtrationFiltration of difficult filter solutions.
AXIVA - MEMBRANE FILTERS PES
Media - Polyethersulfone,
Low protein binding to minimize sample lossWide chemical compatibilityLow sample absorptio
Applications :For Protein samplingFor aqueous as well as organic solvent filtrationPrevent blow through low molecular weight proteinFiltration of difficult filter solutions
| at No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| 230013 R | 13 mm | 0.2 µm | 100 |
| 230013 X | 13 mm | 0.45 µm | 100 |
| 230025 R | 25 mm | 0.2 µm | 100 |
| 230025 X | 25 mm | 0.45 µm | 100 |
| 230047 R | 47 mm | 0.2 µm | 100 |
| 230047 X | 47 mm | 0.45 µm | 100 |
Absorbant pad made cellulos - sterile , individually packed
Ideal for scintilation counting, suspended solids analysis of Industrial wastes and waste water and prefilteration for membrane filters. Widely used by Jal Boards & industries for waste water testing
| Cat No. | Size | Nos/Pkt. |
|---|---|---|
| 133102 | (Cell Harvesting Strip) 102 x 254 mm |
50 |
| 133025 | 2.5 cm (Circles) | 100 |
| 133047 | 4.7 cm (Circles) | 100 |
| 133047B | 4.7 cm (Circles) | 100 X 10 |
| 133055 | 5.5 cm (Circles) | 100 |
| 133070 | 7.0 cm (Circles) | 100 |
| 133090 | 9.0 cm (Circles) | 100 |
| 133110 | 11.0 cm (Circles) | 100 |
| 1133125 | 12.5 cm (Circles) | 100 |
| 133150 | 15.0 cm (Circles) | 100 |
| 133465R | 46 X 57 cm (Sheets) | 25 |
Most retentive grade, Ideal for collection of IgC or other very fine protein precipitates, clarifying chemically aggressive solution, TCLP (EPA method 1311)-use with KST 142
| Cat No. | Size | Nos/Pkt. |
|---|---|---|
| 134025 | 2.5 cm (Circles) | 100 |
| 134047 | 4.7 cm (Circles) | 100 |
Cellulose Nitrate Membrane with black grid & trhe Edge from all sides specially treated to make the area hydrophobic individually packed, sterile ideal for Microbilogy Analysis.
Sterilization : E T O
ApplicationMicrobiological analysisGeneral lab filtrationParticle analysisFor aqueous as well as organic solvent filtration
| Cat No. | Dia/Size | Micron Rating (µm) | Nos./Pkt. |
|---|---|---|---|
| SFMC04R | 4.0 mm | 0.2 μm | 100 |
| SFMC04X | 4.0 mm | 0.45 μm | 100 |
| SFMC13R | 13 mm | 0.2 μm | 100 |
| SFMC13X | 13 mm | 0.45 μm | 100 |
| SFMC25R | 25 mm | 0.2 μm | 50 |
| SFMC25X | 25 mm | 0.45 μm | 50 |
| SFMC33R | 33 mm | 0.2 μm | 50 |
| SFMC33X | 33 mm | 0.45 μm | 50 |
Packed in transparent plastic Jar (Bulk Pack)
ApplicationGeneral lab filtrationFor aqueous as well as organic solvent filtration.
| Cat No. | Dia/Size | Micron Rating (µm) | Nos./Pkt. |
|---|---|---|---|
| SFMC04RB | 4.0 mm | 0.2 μm | 100 |
| SFMC04XB | 4.0 mm | 0.45 μm | 100 |
| SFMC13RB | 13 mm | 0.2 μm | 100 |
| SFMC13XB | 13 mm | 0.45 μm | 100 |
| SFMC25RB | 25 mm | 0.2 μm | 100 |
| SFMC25XB | 25 mm | 0.45 μm | 100 |
| SFMC33RB | 33 mm | 0.2 μm | 50 |
| SFMC33XB | 33 mm | 0.45 μm | 50 |
Specially developed PE filters for pipetting application Free from chemical additives Stops aerosols & contamination from entering into pipette and thus lessen the risk of cross-contamination Permeability is controlled by the combination of pore size and filter length Suitable for PCR and microbiology work.
ndividually Packed Media - PES (Polyethersulfone)
Low protein binding to minimize sample lossWide chemical compatibilityLow sample absorption
Applications :For Analytical and Research applications.Recommended for aqueous as well as organic solvent filtrationFiltration of difficult filter solutions.
| Retention Efficiency | 0.2 μm – LRV > 7 for Brevundimonas diminuta 0.45 μm – LRV > 7 for Serratia marcescens |
|---|---|
| Wettability | Hydrophilic |
| Sterilization | ETO |
| Effective filtration area | 0.1cm2 for 4mm, 0.8 cm2 for 13mm & 3.9 cm2 for 25mm, 24.6 cm2 for 33 mm |
| Hold up volume | <10 μl for 4 mm, < 20 μl for 13 mm & < 50 μl for 25 mm < 80 µl for 33mm (after air purge) |
| Extractable (NVR) | Very low (with in limit as specified in USP XXIV) |
| Initial Water flow rate | 46.2ml/min for 0.2 μm & 68.0ml/min for 0.45 μm (at 10 psi for 25 mm) |
| Filtration Volume | < 1ml for 4mm, 1-10ml for 13mm & 10-100ml for 25mm, 30 to 150ml for 33mm |
Media - Polytetraflouro ethylene (Hydrophilic) with PP supportHydrophilic PTFE Disc Filters are chemically and biologically inert, and stable up-to260C and will with stand most concentrated acids and bases.
HPLC Solvents Sample FiltrationMobile phase separationFor aqueous as well as organic solvent filtration
| Cat No. | Size/Dia | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFNY04 R | 4.0 mm | 0.2 μm | 100 |
| SFNY04 X | 4.0 mm | 0.45 μm | 100 |
| SFNY13 R | 13 mm | 0.2 μm | 100 |
| SFNY13 X | 13 mm | 0.45 μm | 100 |
| SFNY25 R | 25 mm | 0.2 μm | 50 |
| SFNY25 X | 25 mm | 0.45 μm | 50 |
| SFNY33 R | 33 mm | 0.2 μm | 50 |
| SFNY33 X | 33 mm | 0.45 μm | 50 |
| Cat No. | Size/Dia | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFNY04 RB | 4.0 mm | 0.2 μm | 100 |
| SFNY04 XB | 4.0 mm | 0.45 μm | 100 |
| SFNY13 RB | 13 mm | 0.2 μm | 100 |
| SFNY13 XB | 13 mm | 0.45 μm | 100 |
| SFNY25 RB | 25 mm | 0.2 μm | 100 |
| SFNY25 XB | 25 mm | 0.45 μm | 100 |
| SFNY33 RB | 33 mm | 0.2 μm | 100 |
| SFNY33 XB | 33 mm | 0.45 μm | 100 |
Non-Sterile, packed in transparent Plastic Jar
Applications :Suitable for filtration of media filtrationFor mobile phase filtration.
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFCA13 RB | 13 mm | 0.2 μm | 100 |
| SFCA13 XB | 13 mm | 0.45 μm | 100 |
| SFCA25 RB | 25 mm | 0.2 μm | 100 |
| SFCA25 XB | 25 mm | 0.45 μm | 100 |
| SFCA33 RB | 33 mm | 0.2 μm | 100 |
| SFCA33 XB | 33 mm | 0.45 μm | 100 |
Composition : Very strong, heat resistant membranes are manufactured byimpregnating a polyester web with the nylon polymer Inherently hydrophilic Compatible with aqueous and alcoholic solutions and solvents, Pure : negligible organic extractables.
| Cat No. | Dia cm | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| 170013 P | 1.3 | 0.1 | 100 |
| 170013 R | 1.3 | 0.2 | 100 |
| 170013 RB | 1.3 | 0.2 | 100 X 10 |
| 170013 X | 1.3 | 0.45 | 100 |
| 170013 XB | 1.3 | 0.45 | 100 X 10 |
| 170025P | 2.5 | 0.1 | 100 |
| 170025 R | 2.5 | 0.2 | 100 |
| 170025 RB | 2.5 | 0.2 | 100 X 10 |
| 170025 X | 2.5 | 0.45 | 100 |
| 170025 XB | 2.5 | 0.45 | 100 X 10 |
| 170047P | 4.7 | 0.1 | 100 |
| 170047 R | 4.7 | 0.2 | 100 |
| 170047 RB | 4.7 | 0.2 | 100 X 10 |
| 170047 X | 4.7 | 0.45 | 100 |
| 170047 XB | 4.7 | 0.45 | 100 X 10 |
| 170047N | 4.7 | 0.8 | 100 |
FILTER FOR PM AIR MONITORING
Filter media - PTFE, Filter diameter - 46.2 mm, Fitler pore size - 2 micronSupport ring media - Polypropylene
| at No. | Membrane dia | Rating | Nos/Pkt |
|---|---|---|---|
| 240462 PR | 462mm | 2.0 micron | 50 |
Non-Sterile, packed in transparent Plastic Jar
Applications :Suitable for filtration of media filtrationFor mobile phase filtration.
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFCA13 RB | 13 mm | 0.2 μm | 100 |
| SFCA13 XB | 13 mm | 0.45 μm | 100 |
| SFCA25 RB | 25 mm | 0.2 μm | 50 |
| SFCA25 XB | 25 mm | 0.45 μm | 50 |
| SFCA33 RB | 33 mm | 0.2 μm | 50 |
| SFCA33 XB | 33 mm | 0.45 μm | 50 |
Hydrophobic, Non-Sterile, packed in transparent Plastic Jar (BULK PACK)
PTFE SYRINGE FILTERS-NON STERILE
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFTF04 RB | 4.0 mm | 0.2 μm | 100 |
| SFTF04 XB | 4.0 mm | 0.45 μm | 100 |
| SFTF13 RB | 13 mm | 0.2 μm | 100 |
| SFTF13 XB | 13 mm | 0.45 μm | 100 |
| SFTF25 RB | 25 mm | 0.2 μm | 100 |
| SFTF25 XB | 25 mm | 0.45 μm | 100 |
| SFTF33 RB | 33 mm | 0.2 μm | 50 |
| SFTF33 XB | 33 mm | 0.45 μm | 50 |
contains a glass fiber filter with high retention efficiency of 99% for 1.6 m/1.0 m spherical particles. It is very useful when relatively dirty solutions are to be clarified, or for prefiltration.
Materials of Construction :Filter Media : Borosilicate glass fiberHousing : Polypropylene
For High throughputSample cleaningParticle removalRemoves particulate that interferes with UV/VIS spectrophotometric analysisCan be used alone or in series with another Axiva syringe filter
Specification
| Cat No. | Dia/Size | Micron Rating (µm) |
Nos./Pkt. |
|---|---|---|---|
| ICTF13R | 13 mm | 0.2 μm | 100 |
| ICTF13X | 13.0 mm | 0.45 μm | 100 |
| ICTF25R | 25 mm | 0.2 μm | 50 |
| ICTF25X | 25 mm | 0.45 μm | 50 |
| ICTF33R | 33 mm | 0.2 μm | 50 |
| ICTF33X | 33 mm | 0.45 μm | 50 |
Hydrophilic, Packed in transparent Plastic Jar(Bulk Pack)
ApplicationHighly recommended for filtering HPLC, UPLC and ion-chromatographyFor Analytical and aerosol samplingIdeal for filtration of conc. aqueous samplesLowest extractable and excellent solvent resistanceCan be used for almost every application of lab and can replace all other filter media practically.
| Cat No. | Dia/Size | Micron Rating (µm) |
Nos./Pkt. |
|---|---|---|---|
| ICTF13RB | 13mm | 0.2 μm | 100 |
| ICTF13XB | 13.0 mm | 0.45 μm | 100 |
| ICTF25RB | 25 mm | 0.2 μm | 100 |
| ICTF25XB | 25 mm | 0.45 μm | 100 |
| ICTF33RB | 33 mm | 0.2 μm | 50 |
| ICTF33XB | 33 mm | 0.45 μm | 50 |
Media - Mixed Cellulose EstersAXIVA MCE Syringe Filter are specially designed for microbiological analysis.
Key Features :Absolute microbial retentionHigh flow rateLow ExtractablePLow hold up volume
Specification
The AD/X range is specifically designed for high particulate loaded samples & Coloured samples. Constructed of a pigment-free polypropylene housing with two additional layers of Glass Microfibre filters, these filters eliminate sample contamination and allow you to filter even the most difficult samples with less hand pressure. AD/X syringe filters can process three to seven times more sample volume than standard syringe filters. The glass microfibre prefilters are produced from 100% borosilicate glass microfiber in Germany. Top layer retains particles to 1.0 m. A finer glass fibre filter then retains particles down to 0.7 m. The prefilter stack ends with a final membrane. AD/X filter construction facilitates exceptional loading capacity with fast flow rates. This prevents the build up of back pressure typically caused by the blocking of an unprotected membrane.
Features13 and 25 mm diameter syringe filters13 mm devices for samples up to 10 ml and 25 mm devices for samples greater than 10 ml (however, the volume of sample that can be filtered through each filter depends on the characteristics of the sample)Sterile optionsPigment-free polypropylene housing
BenefitsEliminates sample contaminationRequires less hand pressure, even with the most difficult samplesProcesses three to seven times more sample volume
For Analytical and Research applications & for Air samplingUsed under extreme chemical or temp . ConditionsFor non- aqueous base organic solvent filtrationIdeal for filtration of highly aggressive colloidal solutions
* Others sizes can be supplied on request.* Sterile PTFE membrane filters can be supplied also on request
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| 240013 R | 13 mm | 0.2 µm | 100 |
| 240013 X | 13 mm | 0.45 µm | 100 |
| 240025 R | 25 mm | 0.2 µm | 100 |
| 240025 X | 25 mm | 0.45 µm | 100 |
| 240047 R | 47 mm | 0.2 µm | 100 |
| 240047 X | 47 mm | 0.45 µm | 100 |
| Colour | White |
|---|---|
| Surface | Plain |
| Wettability | Hydrophobic |
| Extractable (NVR) | Very low (with in limit as specified in USP XXIV) |
Ideal for microbial analysisSuitable for aqueous and protein filtration
Ideal or microbiolgy analysis - sterile individually packed filter media - C.N white membrane eith black gird
Media - Cellulose Nitrate - Individually Packed
|
|||||||||||||||||
| Colour | White |
|---|---|
| Surface | Plain |
| Wettability | Hydrophobic |
| Operating Temp) | 55 °C (max) |
CA MEMBRANE FILTERS
| at No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| 190013R | 13 mm | 0.2 µm | 100 |
| 190013X | 13 mm | 0.45 µm | 100 |
| 190025R | 25 mm | 0.2 µm | 100 |
| 190025X | 25 mm | 0.45 µm | 100 |
| 190047R | 47 mm | 0.2 µm | 100 |
| 190047X | 47 mm | 0.45 µm | 100 |
For Analytical and Research applications.For aqueous as well as organic solvent filtrationFiltration of difficult filter solutions.
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFPV04 R | 4.0 mm | 0.2 μm | 100 |
| SFPV04 X | 4.0 mm | 0.45 μm | 100 |
| SFPV13 R | 13 mm | 0.2 μm | 100 |
| SFPV13 X | 13 mm | 0.45 μm | 100 |
| SFPV25 R | 25 mm | 0.2 μm | 50 |
| SFPV25 X | 25 mm | 0.45 μm | 50 |
| SFPV33 R | 33 mm | 0.2 μm | 50 |
| SFPV33 X | 33 mm | 0.45 μm | 50 |
For Analytical and Research applications & for Air sampling.Used under extreme chemical or temp . Conditions.For non- aqueous base organic solvent filtrationIdeal for filtration of highly aggressive colloidal solutions.
| at No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFTF04 R | 4.0 mm | 0.2 μm | 100 |
| SFTF04 X | 4.0 mm | 0.45 μm | 100 |
| SFTF13 R | 13 mm | 0.2 μm | 100 |
| SFTF13 X | 13 mm | 0.45 μm | 100 |
| SFTF25 R | 25 mm | 0.2 μm | 50 |
| SFTF25 X | 25 mm | 0.45 μm | 50 |
| SFTF33 R | 33 mm | 0.2 μm | 50 |
| SFTF33 X | 33 mm | 0.45 μm | 50 |
Individually Packed Media - PVDF (Polyvinylidene fluoride).
For Analytical and Research applications.For aqueous as well as organic solvent filtrationFiltration of difficult filter solutions.
AXIVA - GLASS FIBRE PREFILTERS
Suitable for filtration of Protein solutions.For aqueous as well as organic solvent filtration
| Cat No | Dia/Size | Micron Rating | Nos./Pkt |
|---|---|---|---|
| SFCA13 R | 13 mm | 0.2 μm | 100 |
| SFCA13 X | 13 mm | 0.45 μm | 100 |
| SFCA25 R | 25 mm | 0.2 μm | 50 |
| SFCA25 X | 25 mm | 0.45 μm | 50 |
| SFCA33 R | 33 mm | 0.2 μm | 50 |
| SFCA33 X | 33 mm | 0.45 μm | 50 |
Non-Sterile, packed in transparent Plastic Jar (BULK PACK)
Applications :Best media for mobile phase filtration.For media filtration.Filtration of difficult to filter solutions where sterility is not required
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFPV04 RB | 4.0 mm | 0.2 μm | 100 |
| SFPV04 XB | 4.0 mm | 0.45 μm | 100 |
| SFPV13 RB | 13 mm | 0.2 μm | 100 |
| SFPV13 XB | 13 mm | 0.45 μm | 100 |
| SFPV25 RB | 25 mm | 0.2 μm | 100 |
| SFPV25 XB | 25 mm | 0.45 μm | 100 |
| SFPV33 RB | 33 mm | 0.2 μm | 100 |
| SFPV33 XB | 33 mm | 0.45 μm | 100 |
Non-Sterile, packed in transparent Plastic Jar (BULK PACK)
Applications :Best media for mobile phase filtration.For media filtration.Filtration of difficult to filter solutions where sterility is not required
| Cat No. | Dia/Size | Micron Rating | Nos./Pkt. |
|---|---|---|---|
| SFPV04 RB | 4.0 mm | 0.2 μm | 100 |
| SFPV04 XB | 4.0 mm | 0.45 μm | 100 |
| SFPV13 RB | 13 mm | 0.2 μm | 100 |
| SFPV13 XB | 13 mm | 0.45 μm | 100 |
| SFPV25 RB | 25 mm | 0.2 μm | 100 |
| SFPV25 XB | 25 mm | 0.45 μm | 100 |
| SFPV33 RB | 33 mm | 0.2 μm | 50 |
| SFPV33 XB | 33 mm | 0.45 μm | 50 |
HPLC Solvents Sample FiltrationMobile phase separationFor aqueous as well as organic solvent filtration
Individually Packed
Media - Nylon66
HPLC Solvents Sample FiltrationMobile phase separationFor aqueous as well as organic solvent filtration
Technical Specification :