Our Products
Leading Manufacturer, Supplier & Retailer of Big Font Interface ICU 12.1 Inch Portable Patient Monitor.
12.1 color TFT screenMulti-channel displayBig font interfaceST and arrhythmia analysisDrug dose calculation and titration tableOxyCRG dynamic view displayRespiration monitoring with apnea alarms
Alarm review, arrhythmia reviewPatient info. InputAnti-defibrillation designNIBP over pressure protectionPlug-in rechargeable battery, AC/DC available.Supporting wire or wireless network.
Technical Specifications
ECG
Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)Lead selection I, II, III, avR, avL, avF, VWavef orm 2 chLead mode 3 Leads ( R, L, F or RA, LA, LL)Lead selection I, II, III, Wave form 1 chGain 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, auto
HR and Alarm Range Adult 15 300 bpmNeo/Ped 15 350 bpmAccuracy 1% or1bpm, which is greaterResolution 1 bpmSensitivity > 200 (uVp-p)Differential Input Impedance > 5 M
CMRR Monitor > 105 dBOperation > 105 dBDiagnosis > 85 dBElectrode offset potential 300mVLeakage Current < 10 uABaseline Recovery < 3 S After Defi.ECG Signal Range 8 m V ( Vp-p )
Bandwidth Surgery 1 20 HzMonitor 0.5 40 HzDiagnostic 0.05 130 HzCalibration Signal 1 (mVp-p), Accuracy:5%ST Segment Monitoring Range Measure and Alarm -2.0 +2.0 mV
ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, BRADY, MISSED BEATS, PNP, PNC, Alarm Available, Review Available
Respiration
Method Impedance between R-F(RA-LL)Differential Input Impedance > 2.5 MMeasuring Impedance Range 0.33 Base line Impedance Range 2004 KBandwidth 0.12.5HzResp. Rate Measuring and Alarm RangeAdult 0 120 BrpmNeo/Ped 0 150 BrpmResolution 1 BrpmAccuracy 2 Brpm
Apnea Alarm 10 40 S
NIBP
Method OscillometricMode Manual, Auto, STATMeasuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 (Min)Measuring Period in STAT Mode 5 MinPulse Rate Range 40 240 bpmAlarm Type SYS, DIA, MEAN
Measuring and alarm range Adult ModeSYS 40 270 mmHgDIA 10 215 mmHgMEAN 20 235 mmHgPediatric ModeSYS 40 200 mmHgDIA 10 150 mmHgMEAN 20 165 mmHgNeonatal ModeSYS 40 135 mmHgDIA 10 100 mmHgMEAN 20 110 mmHgResolution 1mmHg
Accuracy Maximum Mean error 5mmHgMaximum Standard deviation 8mmHgOverpressure Protection Adult Mode 2973 mmHgPediatric Mode 2403 mmHgNeonatal Mode 1473 mmHg
SpO2Measuring Range 0 100 %Alarm Range 0 100 %Resolution 1 %Accuracy 70% 100% 2 %0% 69% unspecifiedActualization intervalabout 1 Sec.Alarm Delay 10 Sec.Pulse Rate Measuring and Alarm Range 20300 bpmResolution 1bpmAccuracy 3bpm
TEMP
Channel 2Measuring and Alarm Range 0 50 Resolution 0.1 Accuracy 0.2 Actualization intervalabout 1 Sec.Average Time Constant < 10 Sec.
IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm range ART 0 300 mmHgPA -6 120 mmHgCVP/RAP/LAP/ICP-10 40 mmHgP1 / P2-10 300 mmHg
Press Sensor Sensitivity 5 uV/V/mmHgImpedance 300-3000
Resolution 1 mmHgAccuracy 2% or 1mmHg which is greaterActualization interval about 1 secretary
Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, TemperatureOptional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
Additional Information:
Packaging Details : Carton or wooden case