Voltmeter #50575

Rebar Corrosion Voltmeter

12,500 - 18,000 /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Analogue Voltmeter, Digital Voltmeter
  • Color Mulit Colour
  • Power Type AC
  • Frequency 50-100Hz
  • Warranty 1yr
  • Temperature High Temperature
  • Puncture Voltage 0-50Kw, 50-100Kw

Caltech Engineering Services offer Rebar Corrosion Tester is complete economical kit for identifying concrete rebar corrosion as per ASTM C876 or rebar corrosion detection. A STM C876 standard describes procedure for half cell potential of reinforced concrete structure. Accurate measurement of the rebar corrosion rate is necessary for estimating the remaining service life of concrete structures, scheduling repair or maintenance operation using half cell potential test procedure. This is the best corrosion measurement technique for rebar corrosion using half cell potential. Rebar Corrosion Tester detector kit includes half cell and voltmeter integrated with a high impedance and long earth cable and despensing damp sponge. When rebar corrosion voltmeter DV-05 is connected between the reinforcing steel, Cu-CuSO4 reference half cell electrode (Fontana-201F) and specially made highly electrical conductive despensing sponge on the concrete surface where a measurement can be made for the half-cell potential or half cell corrosion mapping. This test method applies to members regardless of their size or the depth of concrete cover over the reinforcing steel. Concrete cover in excess of 3 in. (75 mm) can result in an averaging of adjacent reinforcement corrosion potentials that can result in a loss of the ability to discriminate variation in relative corrosion activity. This gives measurement of the probability of corrosion activity. By testing at a fixed distance apart, a grid of half-cell potentials can be developed and areas delineated. This test method covers the estimation of the electrical half-cell potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel

By connecting a high impedance voltmeter between the reinforcing steel and a reference electrode placed on the concrete surface, a measurement can be made for the half cell potential at the location of the reference cell. This then is a measurement of the probability of corrosion activity in the steel in the vicinity of the reference cell. This is used to locate corroding steel reinforcement. When using Rebar Corrosion Kit, the potential measurements should be interpreted by engineers or technical specialists experienced in the fields of concrete materials and corrosion testing. It is often necessary to use other data such as chloride contents, depth of carbonation, delamination survey findings, rate of corrosion results, and environmental exposure conditions, in addition to corrosion potential measurements, to formulate conclusions concerning corrosion activity of embedded steel and its probable effect on the service life of a structure. 

The reference half cell is copper in a copper sulphate solution. By taking half cell potential measurements a fixed distance apart a grid of half cell potentials can be quickly made and thus areas delineated with a high probability of corrosion of the reinforcing steel. 

To analyze the results, the measurements made with rebar corrosion tester can be plotted on a grid and lines of equipotential contours drawn, highlighting areas of possible corrosion activity.

Details


Download Detail File : Click Here
View Complete Details

CP Voltmeter CPV-4 Tinker & Rasor

  • Scale Dual scale 0 to 1.999 V
The large scale integrated circuit has a built-in filter to reject AC interference. Input resistance of 11 megohms (11 million ohms) yields potentiometer quality voltage readings, and digital readout eliminates interpolation of voltages. This small, lightweight instrument needs no warm-up time, is insensitive to temperature, and can be read in direct sunlight. Low current CMOS circuitry assures long battery life, and the die-cast metal casemakes the CPV- 4 a durable instrument for the field. Study the features and specs and see how they combine to make the Tinker & Rasor CPV- 4 the most accurate and reliable cathodic protection voltmeter ever afforded.
View Complete Details

Digital Voltmeter With Extension Sticks

  • Accuracy +0.1% + last digit
Tinker & Rasor Model CPV-4 Cathodic Protection Voltmeter is a revolutionary instrument for measuring DC structure-to-earth potentials of various buried or submerged metallic objects. Powered by an ordinary 9-volt battery, the Model CPV-4 gives an immediate reading in large inch (12.7mm.) liquid crystal display numerals. The large scale integrated circuit has a built-in filter to reject AC interference. Input resistance of 11 megohms (11 million ohms) yields potentiometer quality voltage readings, and digital readout eliminates interpolation of voltages. This small, lightweight instrument needs no warm-up time, is insensitive to temperature, and can be read in direct sunlight. Low current CMOS circuitry assures long battery life, and the die-cast metal casemakes the CPV- 4 a durable instrument for the field.
View Complete Details

CP Voltmeter CPV-2

  • Accuracy +3% of full scale
Powered by two "AA" penlight cells, the Model CPV-2 requires no push to read switch, and the solid state integrated circuit has built-in filter to reject AC interference. Input resistance of 10 megohms (10 million ohms) of this instrument results in potentiometer quality voltage readings. Red-is-bad and green-is-good segments with 0.85 V as the division line. This versatile meter may also be used without the reference electrode to measure direct current potentials from 0 to 2 volts, such as potentials across an insulated flange, anode to structure, or structure to structure. Study the features and specs and you'll see why corrosion experts agree that the Model CPV-2 offers greater benefits.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • R J Chaudhari (Caltech Instruments Pvt. Ltd.)
  • D-104, Twin Arcade, Military Road, Marol, Andheri East, Mumbai, Maharashtra - 400059
  • https://www.caltechindia.net
  • Share us via
  • Call 08048114885
Manufacturer of Voltmeter from Mumbai, Maharashtra by Caltech Instruments Pvt. Ltd.
Post Buy Requirement
Caltech Instruments Pvt. Ltd.
Mumbai, Maharashtra, India
Verified Add Review

Our Products

  1. Measuring Instruments & Equipment 32 Products available
  2. Fashion Jewelry 4 Products available
  3. Test Kits 4 Products available
  4. Battery Cell 3 Products available
  5. Laboratory Apparatus 5 Products available
  6. Voltmeter 4 Products available
  7. Testing Equipments 6 Products available
  8. Mirrors 5 Products available
  9. Others 59 Products available

Voltmeter #50575

Rebar Corrosion Voltmeter

12,500 - 18,000 /Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Type Analogue Voltmeter, Digital Voltmeter
  • Color Mulit Colour
  • Power Type AC
  • Frequency 50-100Hz
  • Warranty 1yr
  • Temperature High Temperature
  • Puncture Voltage 0-50Kw, 50-100Kw

Caltech Engineering Services offer Rebar Corrosion Tester is complete economical kit for identifying concrete rebar corrosion as per ASTM C876 or rebar corrosion detection. A STM C876 standard describes procedure for half cell potential of reinforced concrete structure. Accurate measurement of the rebar corrosion rate is necessary for estimating the remaining service life of concrete structures, scheduling repair or maintenance operation using half cell potential test procedure. This is the best corrosion measurement technique for rebar corrosion using half cell potential. Rebar Corrosion Tester detector kit includes half cell and voltmeter integrated with a high impedance and long earth cable and despensing damp sponge. When rebar corrosion voltmeter DV-05 is connected between the reinforcing steel, Cu-CuSO4 reference half cell electrode (Fontana-201F) and specially made highly electrical conductive despensing sponge on the concrete surface where a measurement can be made for the half-cell potential or half cell corrosion mapping. This test method applies to members regardless of their size or the depth of concrete cover over the reinforcing steel. Concrete cover in excess of 3 in. (75 mm) can result in an averaging of adjacent reinforcement corrosion potentials that can result in a loss of the ability to discriminate variation in relative corrosion activity. This gives measurement of the probability of corrosion activity. By testing at a fixed distance apart, a grid of half-cell potentials can be developed and areas delineated. This test method covers the estimation of the electrical half-cell potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel

By connecting a high impedance voltmeter between the reinforcing steel and a reference electrode placed on the concrete surface, a measurement can be made for the half cell potential at the location of the reference cell. This then is a measurement of the probability of corrosion activity in the steel in the vicinity of the reference cell. This is used to locate corroding steel reinforcement. When using Rebar Corrosion Kit, the potential measurements should be interpreted by engineers or technical specialists experienced in the fields of concrete materials and corrosion testing. It is often necessary to use other data such as chloride contents, depth of carbonation, delamination survey findings, rate of corrosion results, and environmental exposure conditions, in addition to corrosion potential measurements, to formulate conclusions concerning corrosion activity of embedded steel and its probable effect on the service life of a structure. 

The reference half cell is copper in a copper sulphate solution. By taking half cell potential measurements a fixed distance apart a grid of half cell potentials can be quickly made and thus areas delineated with a high probability of corrosion of the reinforcing steel. 

To analyze the results, the measurements made with rebar corrosion tester can be plotted on a grid and lines of equipotential contours drawn, highlighting areas of possible corrosion activity.

Details


Download Detail File : Click Here
View Complete Details

CP Voltmeter CPV-4 Tinker & Rasor

  • Scale Dual scale 0 to 1.999 V
The large scale integrated circuit has a built-in filter to reject AC interference. Input resistance of 11 megohms (11 million ohms) yields potentiometer quality voltage readings, and digital readout eliminates interpolation of voltages. This small, lightweight instrument needs no warm-up time, is insensitive to temperature, and can be read in direct sunlight. Low current CMOS circuitry assures long battery life, and the die-cast metal casemakes the CPV- 4 a durable instrument for the field. Study the features and specs and see how they combine to make the Tinker & Rasor CPV- 4 the most accurate and reliable cathodic protection voltmeter ever afforded.
View Complete Details

Digital Voltmeter With Extension Sticks

  • Accuracy +0.1% + last digit
Tinker & Rasor Model CPV-4 Cathodic Protection Voltmeter is a revolutionary instrument for measuring DC structure-to-earth potentials of various buried or submerged metallic objects. Powered by an ordinary 9-volt battery, the Model CPV-4 gives an immediate reading in large inch (12.7mm.) liquid crystal display numerals. The large scale integrated circuit has a built-in filter to reject AC interference. Input resistance of 11 megohms (11 million ohms) yields potentiometer quality voltage readings, and digital readout eliminates interpolation of voltages. This small, lightweight instrument needs no warm-up time, is insensitive to temperature, and can be read in direct sunlight. Low current CMOS circuitry assures long battery life, and the die-cast metal casemakes the CPV- 4 a durable instrument for the field.
View Complete Details

CP Voltmeter CPV-2

  • Accuracy +3% of full scale
Powered by two "AA" penlight cells, the Model CPV-2 requires no push to read switch, and the solid state integrated circuit has built-in filter to reject AC interference. Input resistance of 10 megohms (10 million ohms) of this instrument results in potentiometer quality voltage readings. Red-is-bad and green-is-good segments with 0.85 V as the division line. This versatile meter may also be used without the reference electrode to measure direct current potentials from 0 to 2 volts, such as potentials across an insulated flange, anode to structure, or structure to structure. Study the features and specs and you'll see why corrosion experts agree that the Model CPV-2 offers greater benefits.