Our Products
Air Purifiers
2 Products availableWheelbarrow
2 Products availableAutoclaves
2 Products availableWe are leaders in the market for providing best range of Oil Fired Incinerator, Electrical Incinerator, sanitary napkin incinerator, Napkin Disposal Incinerator and Solid Waste Incinerator
Our highly efficient Oil Fired Incinerator is widely used to manage the waste from the hospitals to industrial units. Oil Fired Waste Incinerators operate on the thermal destruction principle that assures high performance with low electricity consumption. We are counted among the major Industrial Oil Fired Incinerators Manufacturers and exporters based in India.
Features
Robust Construction : Cecon Incinerators are constructed with Mild Steel and the body is reinforced with M.S. Angle. The body is painted with heat resistant paint. Incineration Chamber is insulated with high quality ceramic and rock wool blankets and refractory is made up of high grade Alumina and insulating bricks. The Incinerator comprises of two chambers, with heating at Primary Chamber 800oC±50oC for burning waste and Secondary Chamber 1050oC±50oC for exhaust gas combustion. Models : Cecon Incinerators are available in two different models :
Front Loading Type : A solid and sturdy unit having continuous front loading system. The Incineration Chamber is made of high quality refractory and insulation bricks and are fitted with fully automatic burners to produce high intensity flame to dispose of any type of solid and liquid waste. The burners are operational on fuels like diesel or LPG.HSD. This unit is suitable for disposing large quantities of waste including municipal garbage, mixed hospital waste and dry, liquid Industrial waste. Available in capacity ranging from 10Kg/hr. to 500 Kg/hr. Emission Norms : We certify that the emission discharge from Cecon Incinerators shall be within specified limits as prescribed by Central Pollution Control Board & State Pollution Control Board. Accessories
Optional Attachments : Following are the optional attachments which can be provided with Cecon Incinerator :
Applications
Temperature
Technical Data
Model | Capacity | No.of Burners | Burner Type |
---|---|---|---|
CTL - 10 F | 10 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 15 F | 15 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 20 F | 20 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 25 F | 25 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 30 F | 30 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 40 F | 40 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 50 F | 50 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 75 F | 75 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 100 F | 100 Kg/hr. | 2 Nos. | Fully Automatic |
CTL - 150 F | 150 Kg/hr. | 3 Nos. | Fully Automatic |
CTL - 200 F | 200 Kg/hr. | 3 Nos. | Fully Automatic |
CTL - 250 F | 250 Kg/hr. | 3 Nos. | Fully Automatic |
CTL - 300 F | 300 Kg/hr. | 3 Nos. | Fully Automatic |
CTL - 400 F | 400 Kg/hr. | 3 Nos. | Fully Automatic |
CTL - 500 F | 500 Kg/hr. | 3 Nos. | Fully Automatic |
Our Electrical Incinerator is an effectual method to overcome the waste management problems from the hospitals to industrial sectors. We are well reckoned as one of the distinguished industrial incinerators manufacturers based in India. Paper Electric Incinerator offered by us is eco-friendly in nature, thus assure total incineration without any residue. Our Paper Electric Incinerator meets the emission standards of the Pollution Control Board.
Features
Robust Construction : Cecon Incinerators are constructed with Mild Steel and the body is reinforced with M.S. Angle. The body is painted with heat resistant paint. Incineration Chamber is insulated with high quality ceramic and rock wool blankets and refractory is made up of high grade Alumina and insulating bricks. The Incinerator comprises of two chambers, with heating at Primary Chamber 800oC±50oC for burning waste and Secondary Chamber 1050oC±50oC for exhaust gas combustion. Models : Cecon Incinerators are available in two different models :
Front Loading Type : A solid and sturdy unit having continuous front loading system. The Incineration chamber is made of Stainless Steel with ASH disposal from the bottom through ash scrapper. The heating in this Incinerator is done through Heating Elements of Kenthal A1/Nicrome Grade which are designed to work on low watt density thus ensuring long life of heating elements. The system is attachable to all types of Pollution Control Accessories. Available in capacities ranging from 5kg/hr to 500kg/hr. Suitable for wet/semi-wet and dry waste generating from Hospitals, Blood Banks, Pathology Clinics, Nursing Homes, Hotels and Industries. Emission Norms : We certify that the emission discharge from Cecon Incinerators shall be within specified limits as prescribed by Central Pollution Control Board & State Pollution Control Board. Accessories
Optional Attachments : Following are the optional attachments which can be provided with Cecon Incinerator :
Applications
Temperature
Technical Data
Model | Capacity | Power Rating | Type |
---|---|---|---|
CTL - 5F | 5 Kg/hr. | 5 KW | Electrical |
CTL - 10F | 10 Kg/hr. | 5.0 - 7.5 KW | Electrical |
CTL - 15F | 15 Kg/hr. | 10.0 - 12.5 KW | Electrical |
CTL - 20F | 20 Kg/hr. | 15.0 - 17.5 KW | Electrical |
CTL - 25F | 25 Kg/hr. | 20.0 - 22.5 KW | Electrical |
CTL - 30F | 30 Kg/hr. | 25.0 - 30.0 KW | Electrical |
CTL - 40F | 40 Kg/hr. | 30.0 - 35.0 KW | Electrical |
CTL - 50F | 50 Kg/hr. | 45.0 - 50.0 KW | Electrical |