Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Electrical Incinerator, For Industrial Use, Certification : CE Certified

    • Driven TypeElectric
    • CertificationCE Certified
    • ApplicationIndustrial Use
    • Availability100-1000kg
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All Countries Except India
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 22 Years
    • building Nature of Business Exporter
    • gst icon GST No. 09AABCC6413H1ZU

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • ApplicationIndustrial Use
    • Availability100-1000kg
    • Country of Origin220V
    • Driven TypeElectric
    • Total Carbohydrate1 Year
    • Number Of FlowerAutomatic
    • CertificationCE Certified

    Our Electrical Incinerator is an effectual method to overcome the waste management problems from the hospitals to industrial sectors. We are well reckoned as one of the distinguished industrial incinerators manufacturers based in India. Paper Electric Incinerator offered by us is eco-friendly in nature, thus assure total incineration without any residue. Our Paper Electric Incinerator meets the emission standards of the Pollution Control Board.


    Features

    • Complete Solution - electrical and oil-fired models suitable for all types of waste
    • Customized - available in all sizes with accessories, starting from 5 Kg.
    • Convenient - Easy to install, easy to maintain and easy to use
    • Safe - for the operator and for the environment
    • Sturdy - built with MS Steel & well insulated Dual Chamber Construction
    • Efficient - 99% Combustion efficiency
    • Fuel Efficient - Economizes use of fuel and leaves no unburnt residue
    • Trouble Free Performance
    • All types of Pollution Control accessories available
    • Quick disposal of hazardous hospital waste
    • Protect environment & fight pollution by total Incineration
    • Eradicate Infection and contamination spreading source
    • Maintain clean & healthy pollution free surroundings of your Hospitals / Nursing Homes


    Robust Construction : Cecon Incinerators are constructed with Mild Steel and the body is reinforced with M.S. Angle. The body is painted with heat resistant paint. Incineration Chamber is insulated with high quality ceramic and rock wool blankets and refractory is made up of high grade Alumina and insulating bricks.
    The Incinerator comprises of two chambers, with heating at Primary Chamber 800oC±50oC for burning waste and Secondary Chamber 1050oC±50oC for exhaust gas combustion.
    Models : Cecon Incinerators are available in two different models :

    • Electrical Incinerator
    • Oil/Gas Fired Incinerator


    Front Loading Type : A solid and sturdy unit having continuous front loading system. The Incineration chamber is made of Stainless Steel with ASH disposal from the bottom through ash scrapper. The heating in this Incinerator is done through Heating Elements of Kenthal A1/Nicrome Grade which are designed to work on low watt density thus ensuring long life of heating elements. The system is attachable to all types of Pollution Control Accessories.
    Available in capacities ranging from 5kg/hr to 500kg/hr. Suitable for wet/semi-wet and dry waste generating from Hospitals, Blood Banks, Pathology Clinics, Nursing Homes, Hotels and Industries.
    Emission Norms : We certify that the emission discharge from Cecon Incinerators shall be within specified limits as prescribed by Central Pollution Control Board & State Pollution Control Board.
    Accessories

    • Chimney : The chimney is provided with Strong M.S. Base with Inspection Window and inbuilt ladder. Sampling port with sampling platform alongwith optional attachments of Aviation light, Lightning Arrestor and Earthing Strip. The Chimney is connected through centrifugal air blower for effective removal of emission from the entire system.
    • Venturi / Water Scrubber : For removing impurities from the emission and waste out ash contents from the discharged air through chimney. The scrubbing is generally through water but caustic lime solution scrubbing can also be provided to neutralize any gas or acid formation.
    • Foul Odour Treatment Unit: This system can effectively remove foul smell if any, generated through Bio-Medical Waste, Industrial Waste, Zoo Waste & General waste etc. This system is provided with impregnated activated charcoal filter for removing any kind of foul smell before releases through chimney.
    • Cyclone Dust Collector : This system is provided to remove any solid partial from the discharged emission air. This system form a cyclonic condition and removes the particles which are collected in a tray provided with the equipment.
    • Droplet Seperator : This unit is provided to remove any moisture contents from the discharged emission air. This unit is attached after the water scrubber, so that the emission discharge through chimney is free from any moisture contents.
    • Ducting : Internally insulated Strong flange connected with gasket is provided for inter connections of Incinerator to various pollution control accessories.


    Optional Attachments : Following are the optional attachments which can be provided with Cecon Incinerator :

    • Conveyor Belt Arrangement
    • PLC Systems for operation
    • Counter Weight movement of waste charging door


    Applications

    • Hospital waste
    • Industrial garbage
    • Waste oil sludges
    • Municipal waste
    • House hold / Hotel garbage
    • Infectious waste
    • Security documents
    • Chemical waste
    • Radioactive waste
    • Cytotoxic waste
    • Dead Bodies / Animal Carcases


    Temperature

    • Primary Chamber : 800oC±50oC
    • Secondary Chamber : 1050oC±50oC


    Technical Data

    ModelCapacityPower RatingType
    CTL - 5F5 Kg/hr.5 KWElectrical
    CTL - 10F10 Kg/hr.5.0 - 7.5 KWElectrical
    CTL - 15F15 Kg/hr.10.0 - 12.5 KWElectrical
    CTL - 20F20 Kg/hr.15.0 - 17.5 KWElectrical
    CTL - 25F25 Kg/hr.20.0 - 22.5 KWElectrical
    CTL - 30F30 Kg/hr.25.0 - 30.0 KWElectrical
    CTL - 40F40 Kg/hr.30.0 - 35.0 KWElectrical
    CTL - 50F50 Kg/hr.45.0 - 50.0 KWElectrical
    Note :- Power rating of the heating element. Approximate values only.
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • Electrical Incinerator
    • Electrical Incinerator
    • Electrical Incinerator
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Electrical Incinerator?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice