Our Product / Services
Our offered Product range includes Manzel MHH Divider Valves, Electro-Hydraulic Barrel Pumps, APEX Transfer Pumps, Trabon MD Divider Valve and Manual Hand Pump.
30Ton CapacityHydraulic Puller Sets
Just what you need for those big jobs. Not only do you get a 30 ton hydraulic Push-Puller, you also get a 2-jaw and 3-jaw hydraulic puller. Plus, many popular accessories and the hardware to tackle the big jobs right away.
Order No.DescriptionWeight (lbs.)
| IPS30H | 30T capacity hydraulic maintenance puller set. Includes hydraulics, pullers, wooden storage box and accessories listed in Specifications. | 330 |
CAUTION:All the items shown may not withstand the full tonnage specified. Example: When an accessory with a 1 ton capacity is used with a 7 ton puller, the setup can be used only at a force of 1 ton.
The SPX PE45 is an Infinite Stage Pump which increases productivity on the job by providing continuous pressure for up to 2x the speed of typical 2-stage pumps. Jobs get done faster and easier.
Quality means Lower Life-Cycle Costs:
Enhanced Usability:
Designed with Safety in Mind:
Maximum Oil Capacity:(vented reservoir)
1.5 Gallons / 6.75 L (to fill line)
1.12 Gallons / 5.1 L (useable)
Operating Environment:
Temperature: -13F to 122F / -25C to +50C
(If temperatures are at extremes of the operating range, it is recommended to use hydraulic oils that are rated for those temperatures. Refer to service manuals and cooling options)
Sound Level:
87 92 dB
Pressure:
0 10, 000 psi (0 690 bar)
Typical Flow:
575 cu-in/min 48 cu-in/min 9.4 L/min 0.8 L/min
Power:
1.8 HP Universal Motor
( 115 volt 50/60 Hz ) 17 amps
( 230 volt 50/60 Hz ) 8.5 amps
| Length | Width | Height | Weight (without oil) |
||||
|---|---|---|---|---|---|---|---|
| in. | cm | in. | cm | in. | cm | lbs. | kg. |
| 17.7 | 45.0 | 14.0 | 35.6 cm | 26.6 | 67.5 | 71.0 | 32.2 |
1500 BAR Electric pump
Quality Means Lower Life-Cycle Costs:
Enhanced Usability:
Designed with Safety in Mind:
Maximum Oil Capacity:(vented reservoir)
1.0 Gallons / 3.8 L (to fill line)
0.9 Gallons / 3.4 L (useable)
Operating Environment:
Temperature: -13F to 122F / -25C to +50C
(If temperatures are at extremes of the operating range, it is recommended to use hydraulic oils that are rated for those temperatures. Refer to service manuals and cooling options)
Sound Level:
82 86 dB A
Pressure:
0 21, 750 psi (0 1500 bar)
Typical Flow:
168 cu-in/min 8 cu-in/min
2.7 L/min 0.13 L/min
Power:
0.5 HP Universal Motor
(115 volt 50/60 Hz) 11 amps
(230 volt 50/60 Hz) 5.5 amps
| Length | Width | Height | Weight (without oil) |
||||
|---|---|---|---|---|---|---|---|
| in. | cm. | in. | cm. | in. | cm. | lbs. | kg. |
| 14.1 | 35.8 | 7.8 | 19.8 | 16.3 | 41.4 | 45.5 | 20.6 |
Special head design allows you to turn wrench in either direction. Ratcheting action makes it possible to re-grip without removal. For parts of most any size and shape.
| Order No. | Description | Weight (lbs.) |
|---|---|---|
| 7400 | Chain wrench, cap. 1/2" to 4 3/4" O.D. (Capacity= 333 ft. lbs.) | 2.0 |
| 7401 | Chain wrench, cap. 3" to 6 3/4" O.D. (Capacity= 666 ft. lbs.) | 5.0 |
| 209199 | Replacement chain with pin for No. 7400 chain wrench (16" long). | – |
| 209200 | Replacement chain with pin for No. 7401 chain wrench (24" long). | – |
CONSIDERATIONS:
Basic valve types include manually operated, air or solenoid operated and pilot operated. Special application valves for pre-stressing and post-tensioning are also offered.
IN-LINE HYDRAULIC VALVES
Load Lowering Valve- Provides precision metering for controlled return of the cylinder pistion.
Sequence Valve- Used when a cylinder in a multiple cylinder application must advance before any other.
Pressure Reducing Valve- Permits independent pressure control to two or more clamping systems operated by a single power source.
Shut-off Valve- For fine metering of hydraulic oil. Several may be used to control multiple single-acting cylinders.
Check Valve- Permits flow of hydraulic oil in one direction only.
Pressure Relief Valve- Used at remote location in a hydraulic circuit where maximum pressure requirements are less than the setting of the basic overload valve in the pump. Protects a hydraulic system against over pressurization.
Metering Valve- Restricts surges by restricting flow to a certain level; when flow subsides, valve reopens automatically. For systems using large cylinders or extended lengths of hose.
Pressure Regulator Valve- Permits external adjustment of operating pressures at various values below the internal relief valve setting of the pump.
| Order No. | Cylinder Application * |
Operation | Valve Type | Volt | Advance/ Return |
Advance/ Hold Return |
Posi-Check® Feature | Weight (lbs.) |
|---|---|---|---|---|---|---|---|---|
| 9500 | S.A. & D.A. | Manual | 4-way, 3 Pos. Tandem Center | — | No | Yes | No | 4.2 |
| 9501 | S.A. & D.A. | Manual | 4-way, 3 Pos. Closed Center | — | No | Yes | No | 4.2 |
| 9502 | S.A. | Manual | 3-way, 3 Pos. Closed Center | — | No | Yes | Yes | 4.2 |
| 9504 | S.A. & D.A. | Manual | 3/4-way, 2 Pos. | — | Yes | Yes | No | 4.2 |
| 9506 | D.A. | Manual | 4-way, 3 Pos. Tandem Center | — | No | Yes | Yes | 5.1 |
| 9507 | D.A. | Manual | 4-way, 3 Pos. Closed Center | — | No | Yes | Yes | 5.0 |
| 9511 | S.A. & D.A. | Manual | 4-way, 3 Pos. Open Center | — | Yes | Yes | No | 4.2 |
| 9512 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 24 | No | Yes | Yes | 18.1 |
| 9513 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 115 | No | Yes | Yes | 18.1 |
| 9516 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 12DC | No | Yes | Yes | 18.1 |
| 9517 | S.A. | Manual | 2-way, 2 Pos. | — | No | Yes | No | 3.2 |
| 9519 | D.A. | Solenoid | 4-way, 3 Pos. Tandem Center | 230 | No | Yes | Yes | 18.1 |
| 9520 | S.A. | Manual | 4-way, 3 Pos. Tandem Center | — | No | Yes | Yes | 5.1 |
| 9522 | D.A. | Solenoid | 4-way, 3 Pos. Open Center | 230 | Yes | No | No | 15.5 |
| 9523 | S.A. | Pilot Operated Solenoid | 3-way, 2 Pos. | 230 | Yes | No | No | 8.2 |
| 9552 | S.A. & D.A. | Solenoid | 3/4-way, 2 Pos. | 230 | Yes | No | No | 14.6 |
| 9553 | S.A. | Pilot Operated Solenoid | 3-way, 2 Pos. | 24 | Yes | No | No | 8.2 |
| 9569 | S.A. | Solenoid | 3-way, 2 Pos. | 24 | No | Yes | No | 9.6 |
| 9570 | S.A. | Solenoid | 3-way, 2 Pos. | 230 | No | Yes | No | 9.6 |
| 9572 | S.A. & D.A. | Solenoid | 3/4-way, 2 Pos. | 24 | Yes | No | No | 14.6 |
| 9576 | S.A. | Manual | 3-way, 3 Pos. Metering Tandem Center | — | No | Yes | No | 8.5 |
| 9579 | S.A. | Solenoid | 3-way, 2 Pos. | 115 | No | Yes | No | 9.6 |
| 9582 | S.A. | Manual | 3-way, 2 Pos. | — | No | Yes | No | 2.5 |
| 9584 | S.A. | Manual | 3-way, 2 Pos. | — | No | Yes | No | 1.8 |
| 9589 | S.A. | Pilot Operated Solenoid | 3-way, 2 Pos. | 115 | Yes | No | No | 8.2 |
| 9590 | D.A. | Solenoid | 4-way, 3 Pos. Open Center | 115 | Yes | No | No | 15.5 |
| 9592 | S.A. & D.A. | Solenoid | 3/4-way, 2 Pos. | 115 | Yes | No | No | 14.6 |
| 9594 | S.A. & D.A. | Air | 3/4-way, 2 Pos. | — | No | Yes | Yes | 11.0 |
| 9599 | S.A. | Pilot Operated Solenoid | 3-way, 3 Pos. Tandem Center | 24 | No | Yes | Yes | 14.0 |
| 9605 | S.A. | Pilot Operated Solenoid | 3-way, 3 Pos. Tandem Center | 115 | No | Yes | Yes | 14.6 |
| 9609 | S.A. | Pilot Operated Solenoid | 3-way, 3 Pos. Tandem Center | — | No | Yes | No | 8.7 |
| 9610 | S.A. | Auto Pilot Operated | 3-way, 2 Pos. | — | Yes | No | No | 4.2 |
| 9610A | S.A. | Manual | 2/3-way, 2 Pos. | — | No | Yes | No | 4.4 |
| 9615 | D.A. | Solenoid | 4-way, 3 Pos. Open Center | 24 | Yes | No | No | 15.5 |
| 9628 | S.A. & D.A. | Manual | Post Tensioning | — | Special | No | No | 5.4 |
| 9632 | S.A. & D.A. | Manual | Post Tensioning | — | Special | No | No | 13.6 |
| * “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders | ||||||||