My ExportersIndia

For Buyer

For Seller

For Help

LI

Linpin Instruments
location shanghai, China

Write a Review

Our Products

Our product range contains a wide range of Salt Spray Test Chamber, Humidifier Chamber, Thermal Shock Test Chamber, Temperature Humidity Test Chamber and High and Low Temperature Test Chamber

Salt Spray Test Chamber

8.95 Lakh - 2.24 Cr / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name linpin
  • Power Supply 220伏
Model Studio SizeD*W*Hmm DimensionD*W*Hmm
LRHS-108-RJY 450600400 78011401050
LRHS-270-RJY 600900500 96014601150
LRHS-412-RJY 7501100500 110017301240
LRHS-663-RJY 8501300600 123021501410
LRHS-816-RJY 8501600600 123024501460
LRHS-1080-RJY 9002000600 128028501460
Temperature range RT+555
Saturated drum temperature RT+1070
Temperature uniformity 2
Temperature fluctuation 0.5
Salt spray deposition 12ml/80 cm.h16 Hourly average
Compressed air pressure 2.000.01kg/cm
Spraying method Continuous/Periodic Optional
Test time 19999 HMStunable
Cycle time 199 HMStunable
Specimen holder angle 205
Test Methods NSS test, AASS test, CASS test
Case Material Corrosion-resistant, high-strength, anti-aging, high-temperature resistant PP reinforced rigid plastic sheet
Lid Material Corrosion-resistant, high-strength, anti-aging, high-temperature resistant PP reinforced rigid plastic sheet
Air-saturated drum Imported high grade stainless steel SUS304
Pressurized Air Hose Material High quality rubber hose
Other pipelines Thickened Fluorosilicone Rubber Tube
Temperature Controller Adopting Japan UMC brand temperature meter
Temperature Sensor PT100 Platinum resistance thermometer
Heater Titanium Heating Tube
Interrupter Schneider miniature circuit breakers (to prevent short circuits in control circuits)
Standard Configuration V-shaped sample holders, round rods, nozzles, funnels, metering cylinders, mist evacuation tubes
Safety Overall equipment under-phase/reverse-phase, equipment timing, rapid fogging instructions, over-temperature, end of test, low water level protection, leakage, short-circuit
Supply Voltage AC220V10% 50HZ AC380V10% 50Hz
Power 1.6kW/2.5kW/3.0kW/5.6kW/6.5kW/6.7kW
Operating environment 528 85% RH
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the users specific test requirements of the user non-standard Intelligent salt spray test chamber etc.3This technical information, subject to change without notice
View Complete Details

Humidifier Chamber

3.58 Lakh - 12.53 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name Linpin
  • Country of Origin shanghai
Model Studio SizeD*W*Hmm DimensionD*W*Hmm
LRHS-101-LH 450450500 116010001610
LRHS-225-LH 500600750 121011501870
LRHS-504-LH 700800900 126013402070
LRHS-800-LH 80010001000 137015502170
LRHS-1000-LH 100010001000 156015502170
Temperature range 0150
Temperature uniformity 2unladen
Temperature fluctuation 0.5unladen
Humidity range 20%98% RH
Humidity uniformity +2% -3% RH
Humidity fluctuation 2%
Heating rate 1.03.0/min
Cooling rate 0.71.0/min
Time Setting Range 160000M
Test hole Mounted on the left side of the machine for use with external test power or signal cables
Viewing window 210275mm / 395395mmeffective vision
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + glass fiber
Temperature Controller Adopting Japan UMC brand temperature meter
Temperature Sensor PT100 Platinum resistance thermometer
Cooling method Stand-alone cooling
Compressor Tecumseh, France
Standard configuration 1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
Safety Compressor overpressure overload, fan motor overheating, the whole machine phase / reverse phase, over-temperature, the whole equipment timing, leakage protection, overload and short circuit protection.
Supply Voltage AC380V10% 50Hz
Power 4.0kW/5.5kW/8.5kW/11.5kW/11.5kW
Operating environment 528 85% RH
Note:1the above data are in the use of ambient temperature of 25 and well-ventilated conditions measured2Can be customized according to the users specific test requirements of non-standard constant temperature and humidity test chamber etc.3This technical information, subject to change without notice
View Complete Details

Thermal Shock Test Chamber

1.70 Cr / Piece Get Latest Price
  • Brand Name linpin
Model Workshop size(D*W*H) mm External Dimension(D*W*H)mm
LRHS-101B-LV 450×450×500 1700×930×1650
LRHS-150B-LV 500×600×500 1800×1080×1650
LRHS-234B-LV 600×600×650 1950×1080×1950
LRHS-512B-LV 800×800×800 2950×1450×2250
LRHS-753B-LV 970×970×800 3130×1620×2250
LRHS-1000B-LV 1120×1120×800 3300×1780×2250
Impact temperature range A-4085 B-5585 C-6585
temperature deviation ±3 (at no load)
Temperature fluctuation ≤1 (at no load)
heating rate From room temperature to 150≤25min (average throughout)(Temperature rise time is the performance of the high temperature chamber when it is operated alone)
cooling rate From room temperature to -55≤45min (average throughout)(The cooling time is the performance when the cryogenic box operates alone)
Time Setting Range 160000M
Sample basket size 250×250×250mm100L 600×600×500mm512L300×400×250mm150L 760×760×500mm753L400×400×400mm234L 920×920×500mm1000L
Temperature recovery time ≤5min
Transformation time of the carrycot ≤15s
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Imported “UEC” brand temperature meter
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Two-machine cascade refrigeration
Compressor Tycon (France) / BITZER (Germany)
standard configuration Basket sample holder 1 set
security protection Compressor overpressure overload, fan motor overheating, the whole machine under phase / reverse phaseEquipment timing, over-temperature, leakage protection, overload and short-circuit protection
Supply Voltage AC380V±10% 50Hz
Power A17kW/22kW/25kW/53kW/72kW/95kWB17kW/22kW/25kW/53kW/72kW/95kWC20kW/25kW/42kW/65kW/85kW/110kW
operating environment 528 ≤85% RH
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the user’s specific test requirements non-standard thermal shock test chamber etc.3This technical information, subject to change without notice
View Complete Details

Temperature Humidity Test Chamber

3.58 Lakh - 12.53 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name linpin
  • Driven Type Electric
  • Color White
  • Condition New
  • Power 3.5kW-13.0kW
  • Power Supply AC380V±10% 50Hz
  • Application Temperture Humidity Testing
  • Material Imported high-grade stainless steel SUS304
Model Studio SizeD*W*Hmm DimensionD*W*Hmm
LRHS-101B-LJS 450450500 11709501530
LRHS-225B-LJS 500600750 122011001780
LRHS-504B-LJS 700800900 127013501950
LRHS-800B-LJS 80010001000 138015002060
LRHS-1000B-LJS 100010001000 158015102060
Temperature range A-20150 B-40150C-60150 D-70150
Temperature uniformity 2 unladen
Temperature fluctuation 0.5unladen
Time Setting Range 160000M
Humidity range 20%98% RH
Humidity uniformity +2% -3% RH
Humidity fluctuation 2%
Heating rate 1.03.0/min
Cooling rate 0.71.0/min
Test hole Mounted on the left side of the machine for use with external test power or signal cables
Viewing window 210275mm / 395395mmeffective vision
Outer box material High quality A3 steel plate electrostatic spraying
Inside box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + glass fiber
Temperature and humidity controller Adopting Japan UMC brand temperature meter
Temperature and Humidity Sensor PT100 Platinum resistance thermometer
Cooling method Single or double cascade refrigeration
Compressor Tecumseh, France
Standard configuration 1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
Safety Compressor overpressure overload, over-temperature, fan motor overheating, leakage protection whole machine phase / reverse phase, the whole equipment timing, overload and short circuit protection.
Supply Voltage AC380V10% 50Hz
Power (A) 3.5kW/4.0kW/6.0kW/8.0kW/9.0kW(B) 4.0kW/4.5kW/7.5kW/9.0kW/10.5kW(C) 4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
Operating environment 528 85% RH
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the users specific test requirements of the user non-standard high and low temperature alternating humidity test chamber etc.3This technical information, subject to change without notice
View Complete Details

High And Low Temperature Test Chamber

8.95 Lakh - 45.65 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Size 450×450×500
Model Studio Size  (D*W*H)mm DimensionD*W*Hmm
LRHS-101B-L 450×450×500 1160×1000×1610
LRHS-225B-L 500×600×750 1210×1150×1870
LRHS-504B-L 700×800×900 1260×1340×2070
LRHS-800B-L 800×1000×1000 1370×1550×2170
LRHS-1000B-L 1000×1000×1000 1560×1550×2170
temperature range A:-20150     B:-40150C:-60150     D:-70150
Temperature uniformity ≤2(at no load)
Temperature fluctuation ±0.5(at no load)
heating rate 1.03.0/min
cooling rate 0.71.0/min
Time Setting Range 19999H
test hole Mounted on the left side of the machine for use with external test power or signal cables
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Korea Sangwon ST590 Meter
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Single or double cascade refrigeration
Compressor Taikang, France
standard configuration Sample racks, 2 tiers, with condensate catch pan and drain out of the box
security protection Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Supply Voltage AC380V±10 50Hz
Power A3.5kW/4.0kW/6.0kW/8.0kW/9.0kWB4.0kW/4.5kW/7.5kW/9.0kW/10.5kWC4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
operating environment 528 ≤85% RH
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature test chamber etc3This technical information, subject to change without notice
View Complete Details

High And Low Temperature Humidity Test Chamber

3.58 Lakh - 12.53 Lakh / pieces Get Latest Price
  • Min. Order (MOQ) 1 pieces
  • Brand Name linpin
  • Condition New
  • Power 9-12kw
  • Power Supply AC380V±10% 50Hz
  • Application Temperture Humidity Testing
  • Country of Origin shanghai
  • Material High quality A3 steel plate electrostatic spraying
Model Studio Size (D*W*H)mm DimensionD*W*Hmm
LRHS-101B-LS 450450500 116010001610
LRHS-225B-LS 500600750 121011501870
LRHS-504B-LS 700800900 126013402070
LRHS-800B-LS 80010001000 137015502170
LRHS-1000B-LS 100010001000 156015502170
temperature range A:-20150 B:-40150C:-60150 D:-70150
Temperature uniformity 2(at no load)
Temperature fluctuation 0.5(at no load)
Time Setting Range 19999H
Humidity range 20%98% RH
Humidity uniformity +2% -3% RH
Humidity fluctuation 2%
heating rate 1.03.0/min
cooling rate 0.71.0/min
test hole Mounted on the left side of the machine for use with external test power or signal cables
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Korea Saintyear TEMI300
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Single or double cascade refrigeration
Compressor Taikang, France
standard configuration 1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
security protection Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Supply Voltage AC380V10 50Hz
Power A3.5kW/4.0kW/6.0kW/8.0kW/9.0kWB4.0kW/4.5kW/7.5kW/9.0kW/10.5kWC4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
operating environment 528 85% RH
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature humidity test chamber etc3This technical information, subject to change without notice
View Complete Details

Low Temperature Test Chamber

3.58 Lakh - 12.53 Lakh / pieces Get Latest Price
  • Min. Order (MOQ) 1 pieces
  • Country of Origin shanghai
  • Brand Linpin
  • Size 450×450×500
Model Workshop size(D*W*H) mm External Dimension(D*W*H)mm
LRHS-101B-LD 450450500 116010001610
LRHS-225B-LD 500600750 121011501870
LRHS-504B-LD 700800900 126013402070
LRHS-800B-LD 80010001000 137015502170
LRHS-1000B-LD 100010001000 156015502170
temperature range A-20RT B-40RT C-60RT D-70RT
Temperature uniformity 2 (at no load)
Temperature fluctuation 0.5(at no load)
heating rate 1.03.0/min
cooling rate 0.71.0/min
Time Setting Range 19999H
test hole Mounted on the left side of the machine for use with external test power or signal cables
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Korea Sangwon ST590 Meter
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Single or double cascade refrigeration
Compressor Tycon Compressors
standard configuration Sample racks, 2 tiers, with condensate catch pan and drain out of the box
security protection Compressor overpressure overload, fan motor overheating, equipment phase failure/reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Supply Voltage AC380V10% 50Hz
Power A3.5kW/4.0kW/6.0kW/8.0kW/9.0kWB4.0kW/4.5kW/7.5kW/9.0kW/10.5kWC4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
operating environment 528 85% RH
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard Low temperature test chamber etc3This technical information, subject to change without notice
View Complete Details

High And Low Temperature Alternating Test Chamber

3.58 Lakh - 12.53 Lakh / pieces Get Latest Price
  • Min. Order (MOQ) 1 pieces
  • Brand Linpin
  • Material Imported high-grade stainless steel SUS304
Model Studio Size (D*W*H)mm DimensionD*W*Hmm
LRHS-101B-LJ 450450500 116010001610
LRHS-225B-LJ 500600750 121011501870
LRHS-504B-LJ 700800900 126013402070
LRHS-800B-LJ 80010001000 137015502170
LRHS-1000B-LJ 100010001000 156015502170
temperature range A-20150 B-40150C-60150 D-70150
Temperature uniformity 2(at no load)
Temperature fluctuation 0.5(at no load)
Time Setting Range 160000M
heating rate 1.03.0/min
cooling rate 0.71.0/min
test hole Mounted on the left side of the machine for use with external test power or signal cables
viewing window 210 x 275mm or 395 x 395mm (effective field of view)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Insulation material Rigid polyurethane foam + fiberglass
Temperature Controller Imported UEC brand temperature meter
temperature sensor PT100 platinum resistance temperature measurement body
Cooling method Single or double cascade refrigeration
Compressor Taikang, France
standard configuration Sample racks, 2 tiers, with condensate catch pan and drain out of the box
security protection Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Supply Voltage AC380V10% 50Hz
Power (A)3.5kW/4.0kW/6.0kW/8.0kW/9.0kW(B)4.0kW/4.5kW/7.5kW/9.0kW/10.5kW(C)4.5kW/6.5kW/9.0kW/13.0kW/13.0kW
operating environment 528 85% RH
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature alternating test chamber etc3This technical information, subject to change without notice
View Complete Details

High Temperature Test Chamber

3.58 Lakh - 12.53 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name linpin
  • Driven Type Electric
  • Condition New
  • Power 3-6kw
  • Power Supply AC220V±10% 50Hz AC380V±10% 50Hz
  • Application Temperture Humidity Testing
Model Workshop size(D*W*H) mm External Dimension(D*W*H)mm
LRHS-101-LG 450450500 9407501120
LRHS-225-LG 500600750 9909001370
LRHS-504-LG 700800900 119011001620
LRHS-800-LG 80010001000 129013001720
LRHS-1000-LG 100010001000 149013001720
temperature range RT+10200/RT+10300
Temperature uniformity 2%(at no load)
Temperature fluctuation 0.5(at no load)
heating rate 1.03.0/min
Full temperature rise speed View Complete Details

Sand And Dust Test Chamber

3.58 Lakh - 12.53 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Application Construction
  • Type Sand
Model Studio Size (D*W*H)mm DimensionD*W*Hmm
LRHS-512-PS 800800800 130010501750
LRHS-800-PS 80010001000 130012501950
LRHS-1000-PS 100010001000 160012501980
LRHS-1500-PS 100015001000 160017501980
Time Setting Range 19999H adjustable
air velocity Not more than 2m/s
Dust blowing method Continuous and periodic dust blowing at any time setting
sand and dust concentration 24kg/m
Test dust Drying talcum powder, silicate cement, chimney ash, etc.
Vacuum pump flow control 60600L/H
Dust dehumidification Electrically heated heating and dehumidification
Vibration time 1S-99H adjustable
Dust blowing time 1S-99H adjustable
recurring cycle Dust blowing time, stop time and total time can be set arbitrarily.
viewing window 395395mm(Effective vision)
Outer case material High quality A3 steel plate electrostatic spraying
Inner box material Imported high-grade stainless steel SUS304
Temperature Controller Taiwan Weilun 7.0-inch color touch instrumentation
standard configuration 1 layer of sample rack, 1 scraper, 100g of talcum powder
Optional accessories Vacuum system: rotary vane vacuum pump (equipped with vacuum piping device)
security protection Fan motor overheating, the overall equipment phase / reverse phase, leakage protectionTest timing, overload and short-circuit protection, automatic shutdown after fault alarms
Supply Voltage AC380V10% 50Hz
Power 0.9kW/0.9kW/1.2kW/1.2kW
operating environment 528 85% RH
Note:1Can be customized according to the specific requirements of the user non-standard sand and dust test chamber etc2This technical information, if any change without notice

View Complete Details

Environmental Test Chambers

3.58 Lakh - 12.53 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name linpin
  • Driven Type Electric
  • Condition New
  • Application Industrial Use
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us