Our product range contains a wide range of Salt Spray Test Chamber, Humidifier Chamber, Thermal Shock Test Chamber, Temperature Humidity Test Chamber and High and Low Temperature Test Chamber
Mounted on the left side of the machine for use with external test power or signal cables
viewing window
210 x 275mm or 395 x 395mm (effective field of view)
Outer case material
High quality A3 steel plate electrostatic spraying
Inner box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + fiberglass
Temperature Controller
Korea Sangwon ST590 Meter
temperature sensor
PT100 platinum resistance temperature measurement body
Cooling method
Single or double cascade refrigeration
Compressor
Taikang, France
standard configuration
Sample racks, 2 tiers, with condensate catch pan and drain out of the box
security protection
Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature test chamber etc3This technical information, subject to change without notice
Overall equipment under-phase/reverse-phase, equipment timing, rapid fogging instructions, over-temperature, end of test, low water level protection, leakage, short-circuit
Supply Voltage
AC220V10% 50HZ AC380V10% 50Hz
Power
1.6kW/2.5kW/3.0kW/5.6kW/6.5kW/6.7kW
Operating environment
528 85% RH
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the users specific test requirements of the user non-standard Intelligent salt spray test chamber etc.3This technical information, subject to change without notice
From room temperature to 150≤25min (average throughout)(Temperature rise time is the performance of the high temperature chamber when it is operated alone)
cooling rate
From room temperature to -55≤45min (average throughout)(The cooling time is the performance when the cryogenic box operates alone)
210 x 275mm or 395 x 395mm (effective field of view)
Outer case material
High quality A3 steel plate electrostatic spraying
Inner box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + fiberglass
Temperature Controller
Imported “UEC” brand temperature meter
temperature sensor
PT100 platinum resistance temperature measurement body
Cooling method
Two-machine cascade refrigeration
Compressor
Tycon (France) / BITZER (Germany)
standard configuration
Basket sample holder 1 set
security protection
Compressor overpressure overload, fan motor overheating, the whole machine under phase / reverse phaseEquipment timing, over-temperature, leakage protection, overload and short-circuit protection
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the user’s specific test requirements non-standard thermal shock test chamber etc.3This technical information, subject to change without notice
Fan motor overheating, the overall equipment phase / reverse phase, leakage protectionTest timing, overload and short-circuit protection, automatic shutdown after fault alarms
Supply Voltage
AC380V10% 50Hz
Power
0.9kW/0.9kW/1.2kW/1.2kW
operating environment
528 85% RH
Note:1Can be customized according to the specific requirements of the user non-standard sand and dust test chamber etc2This technical information, if any change without notice
Mounted on the left side of the machine for use with external test power or signal cables
Viewing window
210275mm / 395395mmeffective vision
Outer box material
High quality A3 steel plate electrostatic spraying
Inside box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + glass fiber
Temperature and humidity controller
Adopting Japan UMC brand temperature meter
Temperature and Humidity Sensor
PT100 Platinum resistance thermometer
Cooling method
Single or double cascade refrigeration
Compressor
Tecumseh, France
Standard configuration
1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
Safety
Compressor overpressure overload, over-temperature, fan motor overheating, leakage protection whole machine phase / reverse phase, the whole equipment timing, overload and short circuit protection.
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the users specific test requirements of the user non-standard high and low temperature alternating humidity test chamber etc.3This technical information, subject to change without notice
Mounted on the left side of the machine for use with external test power or signal cables
Viewing window
210275mm / 395395mmeffective vision
Outer case material
High quality A3 steel plate electrostatic spraying
Inner box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + glass fiber
Temperature Controller
Adopting Japan UMC brand temperature meter
Temperature Sensor
PT100 Platinum resistance thermometer
Cooling method
Stand-alone cooling
Compressor
Tecumseh, France
Standard configuration
1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
Safety
Compressor overpressure overload, fan motor overheating, the whole machine phase / reverse phase, over-temperature, the whole equipment timing, leakage protection, overload and short circuit protection.
Supply Voltage
AC380V10% 50Hz
Power
4.0kW/5.5kW/8.5kW/11.5kW/11.5kW
Operating environment
528 85% RH
Note:1the above data are in the use of ambient temperature of 25 and well-ventilated conditions measured2Can be customized according to the users specific test requirements of non-standard constant temperature and humidity test chamber etc.3This technical information, subject to change without notice
Mounted on the left side of the machine for use with external test power or signal cables
viewing window
210 x 275mm or 395 x 395mm (effective field of view)
Outer case material
High quality A3 steel plate electrostatic spraying
Inner box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + fiberglass
Temperature Controller
Korea Saintyear TEMI300
temperature sensor
PT100 platinum resistance temperature measurement body
Cooling method
Single or double cascade refrigeration
Compressor
Taikang, France
standard configuration
1 roll of wet bulb gauze, 2 sample racks, with condensate catch pan and drain out of the box
security protection
Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature humidity test chamber etc3This technical information, subject to change without notice
Note:1 the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard Low temperature test chamber etc3This technical information, subject to change without notice
Mounted on the left side of the machine for use with external test power or signal cables
viewing window
210 x 275mm or 395 x 395mm (effective field of view)
Outer case material
High quality A3 steel plate electrostatic spraying
Inner box material
Imported high-grade stainless steel SUS304
Insulation material
Rigid polyurethane foam + fiberglass
Temperature Controller
Imported UEC brand temperature meter
temperature sensor
PT100 platinum resistance temperature measurement body
Cooling method
Single or double cascade refrigeration
Compressor
Taikang, France
standard configuration
Sample racks, 2 tiers, with condensate catch pan and drain out of the box
security protection
Compressor overpressure overload, fan motor overheating, the overall equipment under phase / reverse phaseOver-temperature, overall equipment timing, leakage protection, overload and short-circuit protection
Note:1the above data are in the use of ambient temperature of 25 and well ventilated conditions measured2Can be customized according to the specific requirements of the user non-standard high and low temperature alternating test chamber etc3This technical information, subject to change without notice