Absorb GT1TM (Absorb) is a transformative evolution in percutaneous coronaryintervention (PCI). This first fully bioresorbable vascular scaffold (BVS) dissolves completely over time, leaving nothing* behind but a patent, functioning, restored vesseland renewed possibilities for patients.
The GRAFTMASTER RX is contraindicated for use in: Patients in whom antiplatelet and / or anticoagulation therapy is contraindicated Patients who are judged to have a treatment area that prevents complete inflation of an angioplasty balloon or proper placement of the stent graft
The 20/30 INDEFLATOR Inflation Device registers pressures from VAC to 30 atmospheres(VAC to 441 psi). The device has a quick release lever to quickly engage and disengage the threads on the plunger handle. Athree-way stopcock is included for use during preparation of the device and in conjunction with interventional devices.
The INDEFLATOR Plus 30 Inflation Device is an inflation / deflation device with an analog pressure gauge that registerspressures from VAC to 30 atmospheres (VAC to 441 PSI). The device has a quick-release lever to quickly engage anddisengage the threads on the plunger handle. A three-way stopcock is included for use during preparation of the device and inconjunction with interventional devices
Multi-layer CrossFlex2 Balloon and Slim Seal Technology - Advanced flexibility and low profiles designed for confident track in complex anatomy. Flexible Tungsten Markers - Proprietary radiopaque markers designed for smooth tracking through tortuous anatomy.
Trek's design provides a smooth transitionless feel from the hub to the distal tip for easy access. Transitionless Tip - Designed for excellent guide wire conformability through resistant lesions. Re-Designed Hypotube and Flexible Distal Shaft - Designed for excellent tactile feel and a reduced force to cross challenging anatomy. Skive design provides smooth transition between hypotube and distal shaft.
The guide wires Torque Device is designed to be used with 0.009 (0.23 mm) to 0.018 (0.46 mm) guide wires to facilitate steering of the guide wires within the vascular anatomy.
The COPILOT Bleedback Control Valve has a 0.096 (2.44 mm) inside diameter. This device has two sealsthat operate independently: the clamp seal and the Bleedback Control (BBC) seal. The clamp seal can beopened or closed by rotating the cap. Closing of the clamp seal allows for pressure injections up to 400 psiand also secures the diagnostic / interventional device in position within the vasculature.
SMOOTH. THE MOST AGILE XIENCE. EVER.Smooth Tracking Through Challenging AnatomyBrand New Delivery System to Enhance Acute Performance of the Proven XIENCE ImplantXIENCE SafetyConsistently Low Stent Thrombosis Rates. Trial after Trial.