Bio-Medicus One-Piece Pediatric Arterial Cannulae provide the best arterial flow performance due to their thin wall urethane design. These cannulae feature elongated, one-piece, kink-resistant, wire-wound bodies with beveled tips. This thin-wall, flat-wire reinforced design allows for higher flow rates with minimal pressure differential. An introducer and depth markings on the cannulae bodies permit precise insertion and placement. These Bio-Medicus cannulae are available with Cortiva BioActive Surface* coating.
The Starfish NS Heart Positioner allows for the positioning of the beating heart through a small incision, bringing coronary targets into the operative thoracotomy window. Detachable suction head enables smooth device entry while the rigid shaft provides vacuum to suction pods, eliminating extra suction tubing. Presents coronary arteries for direct vision anastomosisMaximizes surgical field access with remote shaft insertionFeatures integrated suction tubing
The Export Advance aspiration catheter offers a removable preloaded stylet for superior deliverability and kink resistance without sacrificing thrombus capturability.
DLP Straight Tip Arterial Cannulae have traditional non-wire-wound tapered bodies for optimal arterial flow performance for cardiopulmonary bypass. Features include beveled, thin-wall tips and a turret-style flange. This design allows for high flow rates with minimal pressure differential. A tip orientation line permits precise positioning of the cannulae.
These cannulae feature radiopaque tips with 2 side holes, attached to clear bodies. The flanged collar provides a predetermined insertion depth as well as a means of securing the cannula. All cannulae are supplied with a stainless steel introducer needle. Pediatric aortic root cannulae are offered in a shortened 2.5 inch length.
The most complete line of positioners, combining flexibility, low profile, and ease of use.Improved clamp design provides increased stability of the positioner on the retractorClamp can be applied to the retractor with a singlehanded technique allowing for ease of setupSame clamp on the positioner and stabilizer provides a consistent system for beating heart surgery
Medtronic has taken the proven stabilizer clamp technology from our Octopus Evolution Tissue Stabilizer and applied it to our new and improved, next-generation Urchin Evo Heart Positioners. Key benefits of this new design include: Improved clamp design provides increased stability of the positioner on the retractorClamp can be applied to the retractor with a singlehanded technique allowing for ease of setupSame clamp on the positioner and stabilizer provides a consistent system for beating heart surgeryThe positioner continues to feature increased flexibility, range of motion, and a longer reach of the articulating arm for ease in accessing vessels.
This adapter is designed to allow for more accurate pressure monitoring of the aorta and the coronary arteries. This adapter features a latex-free rubber septum to allow access for insertion of a pressure-monitoring needle near the connection to the cardioplegia cannula. The swivel male locking luer is designed to allow the adapter to be connected to the cannulae and moved out of the incision site.
Medtronic Venous Cannulae are designed to provide optimal venous drainage while providing flexibility and ease of use. We offer a variety of single stage venous cannulae with kink-resistant, wire-wound bodies in sizes from 12 Fr 24 Fr. Offered in both straight and right angle with multiport tips and the option for a thin-wall, metal-tip design, our product breadth ensures the availability of a cannula to meet your specific needs.
The primary uses of these sumps are to provide suction and remove unwanted blood and debris either inside or outside of the heart chambers. Tip designs are ideal for atraumatic suction within the heart chambers.
Femoral cannulae provide greater versatility of cannulation techniques to meet the needs of the changing patient population and the desire for smaller thoracic incisions. Designed to be placed in the femoral vein and/or artery, Medtronic Femoral Cannulae are ideally suited for direct insertion. The unique flat, wire-wound, thin-walled construction of the Bio-Medicus Cannulae maximizes flow rates and cannula flexibility. Our product offerings in pediatric sizes ensure the availability of a cannula to meet your specific needs
The DLP Cardio-Kit is designed for you. Medtronic understands that each surgeon and cardiopulmonary circuit is unique and we offer you the ability to customize a Cardio-Kit of Medtronic Cannulae to your specifications. The Cardio-Kit provides simplified packaging for efficiency during the case and a streamlined ordering process designed to meet your specific needs.
Designed to deliver cardioplegia solution to the heart through the coronary sinus, these cannulae feature kink-resistant, wire-wound silicone bodies and smooth manual inflate cuffs with pressure monitoring lines. Cannulae come with either a guidewire stylet or without a stylet. All cannulae come with a syringe for cuff inflation.
Cardioplegia adapters are designed to permit customization of the cardioplegia circuit. Adapters can be used to switch between antegrade and retrograde delivery of cardioplegia. Additional adapters are available to extend the length of the cardioplegia circuit, recirculate the cardioplegia solution or provide an extension to the pressure monitoring line. All adapters are designed to be used in the perfusion circuit and are not patient size specific
Full wall variable braiding technology improves deliverability by increasing kink resistance, resulting in optimal thrombus aspiration capabilityOptimized tip designGuide Catheter compatibility: 6F (min ID 0.070")
Models: AC2200, AC3200, AC2205P, AC3205POffered with a 20 atm or 30 atm pressure gaugeThe pistol-grip fits comfortably in either hand and its trigger mechanism is easy to use
Provides the platform for countless mounting positions for Medtronics stabilizers and positioners.Flexibility retractor can be used in virtually any open-heart procedureLocks blades securely in retractor frame
The AccuMist Device offers advanced fluid/gas mixing technology to create a consistent, predictable blood clearing mist. The malleable shaft and on/off control on the handpiece make it an excellent choice for facilitating a bloodless field. The AccuMist Blower/Mister features: On/off control in hand-pieceEasy-to-hold designMalleable shaftSpecialized nozzle, utilizing a micro-orifice for fluid delivery and a separate orifice for gas delivery
DLP Pediatric One-Piece Arterial Cannulae are designed to deliver arterial return during cardiopulmonary bypass while optimizing access within the sternotomy space on even the smallest pediatric patients. Models range in sizes from 6 Fr to 16 Fr for pediatric patients. Features include beveled, thin-wall tips and elongated one-piece, kink-resistant, wire-wound bodies. This construction allows for higher flow rates with minimal pressure differential. An adjustable introducer allows variable extension beyond the tip and depth marks on the body permit precise positioning of the cannulae. The exclusive Flow-Guard feature provides hemostasis while priming the cannulae.
The Affinity Pixie Oxygenation System delivers performance and versatility for neonates, infants and small children requiring cardiopulmonary bypass at flow rates up to 2.0 L/min
The Sprinter Legend Balloon Catheter provides the latest innovations in balloon technology, including the unique 1.25 mm Zerofold balloon, and is exceptionally equipped to address the most difficult lesions in coronary angioplasty procedures. It is available in diameters of 1.25 4.0 mm and lengths of 6, 10, 12, 15, 20, 25 and 30 mm.
Used to infuse cardioplegia into the aortic root, these needles feature stainless steel tips with a plastic depth stop. These needles are attached to flexible PVC tubing, which includes a drape clamp and female luer.