My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Relays 33 Products available
  2. Power Contactors 6 Products available
  3. LED Lights 5 Products available
  4. Measuring Instruments & Equipment 4 Products available
  5. Circuit Breaker 4 Products available
  6. Busbar System 3 Products available
  7. Changeover Switches 3 Products available
  8. Starters 3 Products available
  9. Fuse Holder 3 Products available
  10. Sockets 2 Products available
  11. Street, Flood & Commercial Lights 2 Products available
  12. Relays & Contactors 2 Products available
  13. Diesel Generators 2 Products available
  14. Switchboards 2 Products available
  15. Electric Fittings And Components 1 Products available
  16. Industrial Machinery 1 Products available
  17. Current Limiting Device 1 Products available
  18. Resins 1 Products available
  19. Safety Switches 1 Products available
  20. Lighting Pole 1 Products available
  21. Lamps 1 Products available
  22. Cabinets & Enclosures 1 Products available
  23. Micro Switches 1 Products available
  24. Switch Gears 1 Products available
  25. Electric Coil 1 Products available
  26. High Voltage Circuit Breaker 1 Products available
  27. Vacuum Circuit Breakers 1 Products available
  28. Engine Components 1 Products available
  29. PH Meter 1 Products available
  30. Others Products 18 Products available

C & S Electric Ltd - Relays

Leading Manufacturer, Supplier & Retailer of Earth Fault Relay, Numerical Multifunction Transformer Protection Relay, Innovative Self Power Protection Relay for RMUs Drawout, Slim Innovative Self Power Protection Relay and Self Power Relay.

Earth Fault Relay

    CS Electric Earth Fault Relay

    Insulation resistance measuring, Measuring aux. voltage UH : 24 V, Measuring frequency : fH = 0.5 Hz, Measuring resistance range : 1 K to 1 M, Max. input voltage : 600 V DC, Exciter DC current measuring , Nominal current IN : 10 A DC, Power consumption in current circuit :
    View Complete Details
    Numerical Multifunction Transformer Protection Relay

      Numerical Multifunction Transformer Protection Relay

      Csepro series offers a multi functional comprehensive smart protection solution for feeder, generator, motor & transformer segment.csepro family of protective relays are advance numerical relays that provide multi protection and monitoring with reliable and fast protection solutions in a single unit.in this family of csepro series, the cseprotxxx is an advanced transformer protection solution which has fast, sensitive and secure protection fortransformer internal & external faults.cseprotxxx also provides an automation solution of power control. It complies with lec60870-5-103, lec6185o, modbus protocolfor high integration of protection & control.

      Application :

      cseprot differential relays are used as the main protection and control units for two winding power transformers, for both internal faults and faults in the influence area of current transformers.csepro-t units require no interposing transformers to adjust ct ratio and vector group correction as these adjustments are made by the relay itself in software. For these transformer winding configuration (vector group yd1, - dd10) & ct ratio are selectable though l-lml / usb communication. One has to select correct transformer winding configuration and ct ratio used in the protection scheme.Csepro-t modelcsepro-t is available in following models: cseprot140: for2-winding transformer protection (see table 23, 24)csepro-t170.

      Benefits

      • Event Record
      • Fault Record
      • DI/DO Matrix Programmability
      • Intelligent key for details of last fault occurred
      • Last 1 0 fault record (nonvolatile memory) with time stamp
      • CSEPROT relays are equipped with self supen/ision function
      FEATURES
      • Programmable Rated Current 1A & 5A for earth, HV & LV winding
      • Measurement, Protection & Metering
      • Draw-out enclosure have modular design with CT shorting
      • Communication (Local & Remote)
      • Disturbance Record
      View Complete Details
      Innovative Self Power Protection Relay for RMUs Drawout

        Innovative Self Power Protection Relay For RMUs Drawout

        • Rated auxiliary voltage UH (Universal) :L: (18V — 60V DC), H: (85V – 260V AC / 110V to 300V DC)
        • Rated supply for digital inputt(Normal voltage): UN L: (18V – 60V DC) H: (85V — 260V AC / 110V to 300V DC)
        • Dropout pickup ratio :95 %

        In the family of protection relay, CSDPR-V2-400 is numeric multi-powered Over-current relay specially designed for ringmain units & feeder protection. It combines the following functions in one unit:

        • Relay get energize either from Current, Aux. voltage, front USB or theinternal battery (whichever is available)
        • O/C, S/C, E/F and E/F High set protection
        • DEFT and Inverse characteristics for O/C and FJF, individually selected for phase and earth fault
        • Unbalance / Asymmetric protection
        • Potential pulse output for direct triggering the circuit breaker coil. Potential free alarm contacts also available
        • Remote trip & Remote protection block input DI
        • RS485 Modbus
        • USB port for PC/ Laptop interface.

        DESIGN :

        • Aux. supply
        • CT current
        • Internal battery
        • USB port

        FEATURES
        • Relay get energize either from Current, Aux. voltage, front USB or internal battery (whichever is available)
        • O/C, S/C, E/F and E/F High set protection
        • DEFT and Inverse characteristics for O/C and FJF, individually selected for phase and earth fault
        • Unbalance / Asymmetric protection
        • Potential pulse output for direct triggering the circuit breaker coil. Potential free alarm contacts also available
        View Complete Details
        Slim Innovative Self Power Protection Relay

          Slim Innovative Self Power Protection Relay

          • Rated auxiliary voltage UH (Universal) :L: (18V — 60V DC), H: (85V – 260V AC / 110V to 300V DC)
          • Rated supply for digital input(Normal voltage): UN L: (18V – 60V DC) H: (85V — 260V AC / 110V to 300V DC)
          • Dropout pickup ratio95 %

          In the family of protection relay, CSPR is numeric multi powered Overcurrent relay specially designed for ring main units &feeder protection. It combines the tollowingfunctions in one unit:CSPR is a high tech and cost optimized protection relay for MV switchboards. Specifically in compact switchboards, the CSPRcan replace the combination of load break switch.

          Design :Relay will get energized from any ofthe following available sources

          • Aux. Supply
          • CT Current
          • internal Battery
          • USB Port
          FEATURES
          • Relay get energize either from Current, Aux. voltage, front USB or internal battery (whichever is available)
          • O/C, S/C, E/F and E/F High set protection
          • DEFT and Inverse characteristics for O/C and E/F individually selected for phase and earth fault
          • Unbalance / Asymmetric protection
          • Potential pulse output for direct triggering the circuit breaker coil.
          • Remote Trip DI
          • 2 Potential Relay Output contact
          • USB port for PC / Laptop interface
          • Circuit breakerfailure protection (50BF)
          • Cold load pickup protection
          • Wide operating ranges of the auxiliary supply voltage (AC/DC)
          • Last 5 Fault & 1 O Event records with Time stamp
          • Two set of setting group
          View Complete Details
          Self Power Relay

            Self Power Relay

            CSE offers a wide range of CT powered relayswhich provide over current, short circuit, instantaneous phase and earth fault functions.CSPR-V11 is a compact relay specificallydesigned for compact MV switchboards with circuitbreakers. CSPR-V1 uses CTs with secondary ratedfor 1A.

            Product Description :

            The CSPR-V1 is a CT-powered protection relaywith inverse time and definite time protectioncharacteristics.CSPR-V1 provides following protection functions:

            • 3 phase definite time over current andshort-circuit protection with variabletripping times (ANSI 50/51)
            • 3 phase over current protection withselectable inverse time characteristics anddefinite time short-circuit current element(ANSI 50/51)
            • Definite time and inverse time earth overcurrent protection by internal calculation(ANSI 50N/51N).
            FEATURES
            • CT powered relay.
            • O/C, S/C, E/F and E/F High Set protection
            • DEFT and Inverse characteristics for O/Cand E/F
            • Impulse output for tripping coil
            • Impulse output for hand reset typemagnetic flag. (Magnetic flag is not a partof standard supply)
            View Complete Details
            Innovative Feeder Protection Relay

              Innovative Feeder Protection Relay

              • Rated Data: Rated current lp1A or 5A , Rated frequency: 50 Hz/60 Hz
              • Drop out to Pickup Ratio>96 %
              • Power consumption in current circuitAt |p=1A 0.1 VA, At |p=5A 0.2 VA

              CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 450 is an advanced feeder protection solution which has fast, sensitive andsecure protection for feeder internal & external faults.CSENEX-l offers different model based features to cover the wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.

              Benefits

              • Three phase instantaneous protection
              • Protection against Cold Load
              • Earth time overcunent and earth instantaneous over current
              • Circuit breaker failure detection
              • Trip circuit supervision
              • Thermal Over load
              • Auto Re-closing function
              • Four sets of setting groups
              • Programmable Scheme Logic
              • Disturbance recording
              • Fault recorder

              FEATURES
              • 1A & 5A rated CT input (programmable)
              • Draw out with self CT shorting
              • DI/DO programmable matrix
              • Protection blocking through DI
              • Three phase time over-current protection
              View Complete Details
              Numerical Non-Directional Current Protection Relay with Disturbance Recording

                Numerical Non-Directional Current Protection Relay With Disturbance Recording

                CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive andsecure protection forfeeder internal & external faults.CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.

                Benefits

                • Three phase instantaneous protection
                • Earth time over-current and earth instantaneous over current
                • Circuit breakerfallure detection
                • Trip circuit supervision
                • Cold Load pickup
                • Harmonic Blocking
                • Fault recorder
                • Event recorder
                • Communication (Local & Remote)
                FEATURES
                • 1A & 5A rated CT input (programmable)
                • Draw out with self CT shorting
                • DI/DO programmable matrix
                • Protection blocking through DI
                • Three phase time over-current protection
                View Complete Details
                Innovative Feeder Protection Relay

                  Innovative Feeder Protection Relay

                  CSENEX Series offers a compact Multi-functional Over-current protection solution for Feeder, Generator, Motor & Transformersegment.CSENEX-l Family of protective relays are numeric relays that provides multi protection and monitoring with reliable and fastprotection solution in a single unit.In this family of CSENEX series, the CSENEX-I 150 is an advanced feeder protection solution which has fast, sensitive andsecure protection forfeeder internal & external faults.CSENEX-l offers different model based features to coverthe wide range of user.The CSENEX-I relays have been designed for controlling, protecting and monitoring industrial, utility distribution networks andsubstations. They can also be used as part of a protection scheme for feeders, transformers and generators.Three Phase Over-current Protection (50/51):The independent two stages are available for phase fault protection. For l> the user may independently select definitetime delay or inverse time delay with different type of curves. The second HiSet stage can be configured with definitetime only.Earth Fault Protection (50N/51 N): The independent two stages are available for earth fault protection. For first stage (le>) the user can select definite timedelay or inverse time delay with different type of curves. The second Hi-Set stage can be configured with definite timeonly.

                  Benefits

                  • Three phase instantaneous protection
                  • Earth time over-current and earth instantaneous over current
                  • Circuit breakerfallure detection
                  • Trip circuit supervision
                  • Cold Load pickup
                  • Harmonic Blocking
                  • Fault recorder
                  • Event recorder
                  • Communication (Local & Remote)
                  FEATURES
                  • 1A & 5A rated CT input (programmable)
                  • Draw out with self CT shorting
                  • DI/DO programmable matrix
                  • Protection blocking through DI
                  • Three phase time over-current protection
                  View Complete Details
                  Sensitive Earth Fault Relay

                    Sensitive Earth Fault Relay

                    The application of powerful microprocessors with MRand IR-relays of the HIGH TECH RANGE provides alarge variety of advantages over power protectionsystems of the traditional type.The MR-protection relays are based exclusively on themicroprocessor technology. They represent our mostefficient generation of power protection systems.Because of their capabilities to process measuredvalues digitally and to perform arithmetical and logicaloperations, they are superior to the traditional analogsystems.Besides, the digital protection relays offer importantadditional advantages such as very low powerconsumption, adaptability, flexible construction, selection of relay characteristics etc.The IR-protection relays are based on themicroprocessor technology or on the analogtechnology. They represent a more cost savinggeneration of relays of the HIGH TECH RANGE, usedfor basic equipment protection.The IR-protection relays are superior to conventionalprotective devices because of their followingcharacteristics:

                    • Integration of multiple protective functions intoone compact housing
                    • User-friendly setting procedure by means of DIP-switches
                    • Compact construction type by SMDtechnology

                    MR-protection relays are used for more complexprotective functions, such as earth fault directionaldetection, and also in cases where easy operation, quick fault-analysis and optimal communicationcapabilities are required.All relays of the HIGH TECH RANGE are availablefor flush mounted installation, as well as for rackmounting. Plug-in technology is used. Of course, allrelays comply with the IEC/DIN regulations requiredfor the specific protection application.

                    Benefits

                    • Extremely wide setting range with fine grading
                    • Wide range of operation of the supply voltage(AC/DC)
                    • Coding for the self-holding function or automaticreset of the LEDs and trip relays
                    • Frequency range 50/60 Hz
                    • Rated current TA or 5A
                    • Output relay with 2 change-over contacts
                    FEATURES
                    • Static protective device
                    • Earth fault detection with core balance C.T. or in Holmgreen circuit
                    • Low pass filter for suppression of harmonics
                    • Wide range of operation of the supply voltage (AC/DC)
                    View Complete Details
                    Restricted Earth Fault Relay

                      Restricted Earth Fault Relay

                      The application of powerful microprocessors with MRand IR-relays of the HIGH TECH RANGE provides alarge variety of advantages over power protectionsystems of the traditional type.The MR-protection relays are based exclusively on themicroprocessor technology. They represent our mostefficient generation of power protection systems.Because of their capabilities to process measuredvalues digitally and to perform arithmetical and logicaloperations, they are superior to the traditional analogsystems.Besides, the digital protection relays offer importantadditional advantages such as very low powerconsumption, adaptability, flexible construction, selection of relay characteristics etc.The IR-protection relays are based on themicroprocessor technology or on the analogtechnology. They represent a more cost savinggeneration of relays of the HIGH TECH RANGE, usedfor basic equipment protection.The IR-protection relays are superior to conventionalprotective devices because of their followingcharacteristics:

                      • Integration of multiple protective functions intoone compact housing
                      • User-friendly setting procedure by means of DIP-switches
                      • Compact construction type by SMDtechnology

                      MR-protection relays are used for more complexprotective functions, such as earth fault directionaldetection, and also in cases where easy operation, quick fault-analysis and optimal communicationcapabilities are required.All relays of the HIGH TECH RANGE are availablefor flush mounted installation, as well as for rackmounting. Plug-in technology is used. Of course, allrelays comply with the IEC/DIN regulations requiredfor the specific protection application.

                      Benefits

                      • Extremely wide setting range with fine grading
                      • Wide range of operation of the supply voltage(AC/DC)
                      • Coding for the self-holding function or automaticreset of the LEDs and trip relays
                      • Frequency range 50/60 Hz
                      • Rated current TA or 5A
                      • Output relay with 2 change-over contacts.
                      FEATURES
                      • Static protective device
                      • Single-phase current measuring (lRll-ER) aszero-current differential protection (restrictedearth fault 64 REF)
                      • Three-phase current measuring (lRll-3ER) asphase-current differential protection
                      • High stability by serial stabilizing resistor Rsr perphase
                      • High sensitivity by low input burden of C.T
                      View Complete Details
                      Numerical Voltage Protection Relay

                        Numerical Voltage Protection Relay

                        CSENEX-U Series relays provide reliable and high performance protection. TheCSENEXU 200 is a relay for AC voltage supervision with universal application; it protects the three phase network against over, under voltage, unbalance or earth faults in isolated networks. Beside the pure RMS value measurement ofline voltage the CSENEX-U 200 can detect the phase sequence, voltage unbalance and earth faults. TheCSENEX-U relay has been designed for controlling, protecting and monitoring industrial, utility distribution networks andstations. They can also be used as part of a protection scheme forfeeders, transformers and generators

                        Benefits

                        • Last 10 fault record (non-volatile memory) with time stamp
                        • Last 50 event record (nonvolatile memory) with time stamp
                        • CSENEX-U relays are equipped with self supervision function
                        • Suitable for Star & Delta configuration
                        FEATURES
                        • Draw out enclosure have modular design
                        • Measurement & Protection
                        • SCADA Communication (Local & Remote)
                        • DO Matrix Programmability
                        • Intelligent key for DO status, details of fault pickup & status of last fault occurred
                        View Complete Details
                        AMF Relay

                          CS Electric AMF Relay

                          EC-RXA-V2 is a AUTOMATIC/MANUAL Generator controller module including protection for (STAND BY) GENSElS. It uses single advanced micro controller chip for an easy and trouble free GENSET control. it is cost ef fective solution for AMF controlling system. If mains voltage in any phase fails (either voltage or frequency goes out of the selected range) EC-RXA-V2 initiates an automatic GEN-SET start cycle including load transfer by switching the contactors mounted in the panel. After the mains is restored the load will be automatically removed from GEN-SET and transferred to mains.GEN-SET will stop after a set cool down time. During all cycles, generator is fully monitored and protected against any fault. All the alarm occurring at abnormal GEN-SET conditions are detected and displayed on LCD display and if necessary GEN-SET is stopped and hooter gets activated.

                          Benefits

                          • 9 LEDs, 7 Digital inputs and 6 Potential outputs fordriving of relays on external relay card
                          • Last 5 Fault records with date and time stamp
                          • Logical interlockfor Mains & DG breakerforfail safe operation
                          • Wide array of time circuits for start delay, stop delay, mains restoration, re- cooling etc
                          • Full engine safety functions: The unit has LLOP, HOT, Over speed, Start Failure, Stop Failure, Fuel level trip, Emergency stop and Overload tripfunctions.
                          FEATURES
                          • Display of 3 Phase Mains Parameters: Voltage and Frequency
                          • Display of Generator Parameters: Voltage, Frequency, Speed, Flun Hours
                          • Measurement and display of Load current and Instantaneous load in kW
                          • 34 Programmable Parameters including settings of voltage, frequency, different delay times
                          • Site name and number are programmable
                          View Complete Details
                          Trip Circuit Supervision Relay

                            Trip Circuit Supervision Relay

                            The Trip circuit of circuit breaker is normally wired through CB auxillary contacts and other interlocks (like spring charging full etc) and then connected to Trip solenoid coil of circuit breaker and control voltage source through fuse links.MRA- Pro-V2 continuously monitors these junction points. In the event of fault (like TC coil is open or short, TC coil supply is less than 40% or CB contact failure) in the trip circuit it immediately triggers the internal timer. After expiration of supervision time delay if the faulty condition persists then it is reported as fault by two output relay operation and CB failed LED indication. This scheme ensures that all trip circuit wiring (tripping route) from trip contact to the trip coil is supervised in either the breaker closed or open condition.

                            There are two modes of operation as under

                            a) Auto Mode: In this mode Trip circuit faulty status indication automatically gets reset once Trip circuit becomes healthy.

                            b) Manual Mode: In this mode Trip circuit faulty status indication will not be reset unless user reset it through a front RESET key through a single press.

                            To facilitate routine checkup there is a provision for TEST function inMRA- Pro-V2. User can enter into this mode by keeping the RESET key in pressed condition and then providing the auxiliary supply. To bring back to normal operation from this mode user has to switch off and then switch on the auxillary supply ofMRA- Pro-V2.

                            Benefits

                            • Operation delay to avoid spurious signals for instance , on circuit breaker operations
                            • Functional operation indication by 4 LEDs namely CB OK, CB Fail, Manual and edit
                            • Auto/ Manual operation mode
                            • Wide range auxillary supply.
                            FEATURES
                            • Continuous Trip circuit supervision of both pre closing and post closing conditions in circuit breaker
                            • Detection and alarm of trip circuit supply failure and circuit breaker tripping mechanism failure such as loss of voltage, trip circuit connection, contact degeneration of wires etc
                            • Single-Phase DB monitoring
                            • Flush mounting enclosure
                            • 2 Output contacts
                            View Complete Details
                            High Speed Lockout/ Master Trip Relay

                              High Speed Lockout/ Master Trip Relay

                              The lockout relay CLR series are voltage operated single element electro-mechanical, hinged armature type relay mainly used in protection, control & alarm circuits. CLR relays are available in two basic model CLR-H and CLR-S. Lockout relay CLR-H is provided with hand reset contacts. CLR-S is self reset type.The CLR series of relays are used in various application such as:

                              • Switching functions in protection and control circuits
                              • High speed tripping functions requiring a number of simultaneous switching operation
                              • Control with interlocks and inter tripping

                              The design of lockout relays is electro-mechanical, hinged armature type. It has been ensured to have consistent electrical and magnetic qualities while designing the armature, yoke and core materials. The coil is wound with wires of high thermal rating to withstand the problems of overheating due to continuous rating. It is also ensured that the coil though rated for the very short time will tolerated the high burden to ensure faster operation.

                              Benefits

                              • Hand reset or self reset contacts
                              • Hand reset flag indication
                              • Compact panel mounting case
                              • High speed with positive operation.
                              FEATURES
                              • Electro-mechanical design
                              • Suitable for tripping, signalling in protection and control systems
                              • Consistent and repeat accuracy
                              • High resistance to shock and vibration
                              • Flexible, user friendly standardized contacts arrangement
                              View Complete Details
                              High Speed Self Reset Type Master Trip Relay

                                High Speed Self Reset Type Master Trip Relay

                                The lockout relay CLR series are voltage operated single element electro-mechanical, hinged armature type relay mainly used in protection, control & alarm circuits. CLR relays are available in two basic model CLR-H and CLR-S. Lockout relay CLR-H is provided with hand reset contacts. CLR-S is self reset type.The CLR series of relays are used in various application such as:

                                • Switching functions in protection and control circuits
                                • High speed tripping functions requiring a number of simultaneous switching operation
                                • Control with interlocks and inter tripping

                                The design of lockout relays is electro-mechanical, hinged armature type. It has been ensured to have consistent electrical and magnetic qualities while designing the armature, yoke and core materials. The coil is wound with wires of high thermal rating to withstand the problems of overheating due to continuous rating. It is also ensured that the coil though rated for the very short time will tolerated the high burden to ensure faster operation.

                                Benefits

                                • Hand reset or self reset contacts
                                • Hand reset flag indication
                                • Compact panel mounting case
                                • High speed with positive operation.

                                FEATURES
                                • Electro-mechanical design
                                • Suitable for tripping, signalling in protection and control systems
                                • Consistent and repeat accuracy
                                • High resistance to shock and vibration
                                • Flexible, user friendly standardized contacts arrangement
                                View Complete Details
                                Directional Overcurrent

                                  Directional Overcurrent

                                  • Rated data : Nominal current IN 1A or 5A, Nominal voltage UN 100 V, 230 V, 400 V, Nominal frequency fN 50 Hz; 60 Hz adjustable
                                  • Power consumption incurrent circuit : at IN = 1 A 0.2 VA, at IN = 5 A 0.1 VA
                                  • Power consumption involtage circuit : < 1 VA
                                  • Thermal with stand involtage circuit : continuously 1.5 x UN
                                  • GL-Approbation : 98776-96HH
                                  • Bureau Veritas Approbation : 2650 6807 A00 H
                                  View Complete Details
                                  Underfrequency Relay

                                    Underfrequency Relay

                                    Rated voltage Un : 110 V, 230 V, 400 V AC frequency range at 50 Hz rated frequency : 46 50 Hz 60 Hz rated frequency : 55.2 60 Hz Tolerance : 1 % of of rated frequencyHysteresis : 0.5 % of of rated frequency power consumption : 3.7 VA Thermal load carrying : continuously 1.3 x Uncapacity Returning time : 250 ms Minimum operating time : 250 ms
                                    View Complete Details
                                    Overfrequency Relay

                                      Overfrequency Relay

                                      • Rated voltage Un : 110 V, 230 V, 400 V AC
                                      • frequency range at50 Hz rated frequency : 50 54 Hz60 Hz rated frequency : 60 64.8 Hz
                                      • Tolerance : 1 % of of rated frequency
                                      • Hysteresis : 0.5 % of of rated frequency
                                      • power consumption : 3.7 VA
                                      • Thermal load carrying : continuously 1.3 x Uncapacity
                                      • Returning time : 250 ms
                                      • Minimum operating time : 250 ms
                                      View Complete Details
                                      Main De-coupling Relay

                                        Main De-coupling Relay

                                        • Rated data : Nominal voltage UN 100 V, 230 V, 400 V, Nominal frequency fN 40 70 Hz
                                        • Power consumption involtage circuit :
                                        View Complete Details
                                        Vector Surge Relay

                                          Vector Surge Relay

                                          • Rated data : Nominal voltage UN 100 V, 230 V, 400 V
                                          • Nominal frequency fN 40 70 Hz
                                          • Power consumption involtage circuit :
                                          View Complete Details
                                          Rotor Earth Fault Relay

                                            Rotor Earth Fault Relay

                                            • Insulation resistance measuring:
                                            • Measuring aux. voltage UH : 24 V
                                            • Measuring frequency : fH = 0.5 Hz
                                            • Measuring resistance range : 1 K to 1 M
                                            • Max. input voltage : 600 V DC
                                            • Exciter DC current measuring :
                                            • Nominal current IN : 10 A DC
                                            • Power consumption in current circuit :
                                            View Complete Details
                                            over Voltage Relay

                                              CS Electric Over Voltage Relay

                                              • Roled voltage Un : 110 V, 230 V, 400 V AC
                                              • Rated frequency range : 45-66 Hz
                                              • Accuracy : 5 % of set value
                                              • power consumption involtage circuit : 3.5 VA
                                              • Thermal load carrying : constant 1.3 x Uncapacity of the voltage circuit
                                              • Dropout to pickup ratio : dependent on the set hysteresis
                                              • Dropout time : 300 ms
                                              • Minimum operating delay : 300 ms
                                              View Complete Details
                                              Numeric Motor Protection Relay

                                                Numeric Motor Protection Relay

                                                In mPRO-200the protection feature is based on mathematical model ofmotor thermal image. The motor thermal overload protectionfunction calculates the heat accumulated in the rotor andstator based on the effective heating current , integrated overa time. The relay appropriately takes in to accountcooling of the winding by gradually emptying the accumulatedcurrent bucket. The relay displays the status of thermalcondition of motor windings as a % of maximum permissibleThermal capacity.If inverse overload characteristic (lN/) is selected then only theeffect of thermal memory phenomenon is enabled. If current inany of the three phases exceeds over-current setting l> as wellas accumulated thermal capacity (Thermal MEM) is >=100%then mPRO will trip the motor. If thermal memory isaccumulated then Relay Contact Reset depends on RelayReset selection (AUTO/MANUAL) and Thermal Reset selection(Disable/Enable).

                                                Mechanical equipments such as pumps orfans can be quicklydamaged if it jams, resulting in a locked rotor stall. The MProwill trip when the running current exceeds the set value (Stall)value after the Stalled Rotor Time (tStall). Set this value toOFF, if stall protection of driven equipment is not requiredsince the thermal overload protection will protect the motor.This feature is blocked during the inrush of motor starting.mPRO provides protection against over temperature bymonitoring the temperature in the motor winding. Highwinding temperature is caused by phase unbalance, phasefail, high torque starting, insufficient cooling etc. mPRO willtrip the motor in running condition after PTC trip time (tPtc)expires. once temperature monitored via external PTCthermistor exceeds the PTC Trip value (PtcTrp).

                                                Benefits

                                                • The phase unbalance condition is checked only during runningcondition of the motor
                                                • In the event of phase reversal, the relay trips after set timetPhRev. It helps to protect a three phase motor whileinstallation
                                                • During motor start-up, a locked rotor is detected with the stateof increased phase current above the set value (LKR) even afterthe set start time (tLKR).
                                                FEATURES
                                                • Monitors the flow of the current from which thefollowing operational conditions of the motor are gathered:-STOP, START &RUNNING
                                                • Allows user to enable fail safe operation for DO-1contacts.
                                                • When mPRO generates a trip signal, the DO-1 relay coil isde-energized
                                                • Short circuit protection is provided by tripping the relay whenthe motor operating current in any ofthe three phases exceedsthe value corresponding to Short circuit setting
                                                • During a phase loss, the motor winding current will increase by150% or more
                                                View Complete Details
                                                Analogue Motor Protection Relay

                                                  Analogue Motor Protection Relay

                                                  Relays with builtin MCU (Micro Processor Control Unit) Environment operational temperature (-25C to +70 C) Common use of the Screw type & Tunnel typeApplicable to the inverter circuit (202O0 Hz) Mounting options : 35mm Din-rail or ScrewFail safe operation.FEATURES
                                                  • Multiple protection: Over current/ Phase failure/Stall /Asymmetry/ Phase reverse
                                                  • Current setting upto 80A in 3 frame sizes
                                                  • Fault diagnose by LEDs indication
                                                  • Time settingO-30 sec
                                                  • Accuracy:Current/Time
                                                  View Complete Details
                                                  Digital Motor Protection Relay

                                                    Digital Motor Protection Relay

                                                    Digital Ammeter functionTime setting: Inverse time (O-60 sec), Definite time (O60 sec) starting & Delay timeoperating timeAccuracy : Current/Timei5% of settingFail safe operationAlert function(60-110% of set current)lnverse/ Definite time characteristics, site selectableC.T. ratio setting in CSMPM06 frame 0nly.


                                                    FEATURES
                                                    • Digital Relay with built-in MCU (Micro Processor Control Unit)
                                                    • Multiple protection: Over load / Phase failure/Stall /Asymmetry/ Phase reverse Earth Fault
                                                    • Current setting 0.5-6A&5-60A
                                                    • Current setting 0.5-6A can be used upto 600A with external
                                                    • Fault diagnostic seven segmentb display of fault & values
                                                    View Complete Details
                                                    Electrical Control Relay

                                                      CS Electric Electrical Control Relay

                                                      Micro controller technology.Wide range of auxiliary supply: 7 V to 35Vdc.Withstands a dip to OV of auxiliary supply for second.Flush mountingAlphanumeric LCD display with keypad for ease of operation.Display and supervision of three phase mains voltages for UV, OV & unbalance.
                                                      View Complete Details
                                                      over Voltage Relay

                                                        CS Electric Over Voltage Relay

                                                        Numeric DSP technology based relayDigital tiltering of the measured values by using discrete Fourier analysis to suppress higher harmonics and D.C. components induced by faults or system operationsTwo Groups of configuration parameterProtection ANSI: 27, 59, 59N, 47, 59D
                                                        View Complete Details
                                                        Differential Protection Relay

                                                          CS Electric Differential Protection Relay

                                                          Three phase differential protection (87) with harmonic restrainThree phase Instantaneous differential protection (87)Restricted earth protection (87G) on either Primary or Secondary (MMI selection)Three phase time and instantaneous over current (5051) protection (HV & LV side)Ground time (51 G) and instantaneous over current protection (5OG) (either HV or LV side)Current unbalance (46) (HV& LV side)
                                                          View Complete Details
                                                          Current Relay

                                                            CS Electric Current Relay

                                                            Three Phase Time Over-current ProtectionThree Phase Instantaneous ProtectionEarth Time Over-current and Earth Instantaneous Over CurrentCircuit Breaker Failure DetectionFault Recorder
                                                            View Complete Details
                                                            Short Circuit Protection Relay

                                                              CS Electric Short Circuit Protection Relay

                                                              Three Phase Time Over-current ProtectionThree Phase Instantaneous ProtectionEarth Time Over-current and Earth Instantaneous Over CurrentCircuit Breaker Failure DetectionFault Recorder
                                                              View Complete Details
                                                              Digital Protection Relay

                                                                CS Electric Digital Protection Relay

                                                                Digital Relay with built-in MCU (Micro Processor Control Unit)Multiple protection: Over load Phase failureStall Asymmetry Phase reverse Earth FaultCurrent setting 0.5-6A&5-60ACurrent setting 0.5-6A can be used upto 600A with externalFault diagnostic seven segmentb display of fault & values
                                                                View Complete Details
                                                                Auxiliary Relays

                                                                  CS Electric Auxiliary Relays

                                                                  Continuous Trip Circuit Supervision of both pre closing and post closing conditions in circuit breakerDetection and Alarm of trip circuit supply failure and circuit breaker tripping mechanis failure such as loss of voltage, trip circuit connection, contact degeneration in wires, contacts and coilsSingle Phase CB monitoringFlush mounting enclosure2 Output contactsOperation delay to avoid spurious signals for instance on circuit breaker operationsFunctional Operation indication by 4 LEDs namely CB OK, CB Fail Manual & EditTest function for Self test facilitates routine maintenanceAuto Manual operation mode
                                                                  View Complete Details
                                                                  Tripping Relay

                                                                    CS Electric Tripping Relay

                                                                    Continuous Trip circuit supervision of both pre closing and post closing conditions in circuit breakerDetection and alarm of trip circuit supply failure and circuit breaker tripping mechanism failure such as loss of voltage, trip circuit connection, contact degeneration of wires etcSingle-Phase DB monitoringFlush mounting enclosure2 Output contacts
                                                                    View Complete Details
                                                                    Tell Us What are you looking for? Will call you back

                                                                    Contact Us

                                                                    • icon userS. C. Jain(C & S Electric Ltd)
                                                                    • location icon222, Okhla Industrial Estate, Phase Iii, New Delhi - 110020
                                                                    • share iconShare us via
                                                                    • Manufacturers In Delhi