My ExportersIndia

For Buyer

For Seller

For Help

Inverters

We offer the best product range of Inverter and Multipurpose CFL Inverter.

Inverter

DATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip incU.S.A. The Digital Technology used in the product offers HighReliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.

  • MICRO CONTROLLER BASED DESIGN
  • LED/LCD Alphanumeric Display
  • Software controlled CC-CV Charging Technology
  • Smart Multistage Charging with Top-up Pulse Mode
  • Battery status Monitoring and Display
  • Realtime input Main Voitage Monitoring
  • Load Status Display on Battery Mode
  • Smart Overload Sensing with Auto-Restart
  • SAFETY INSTRUCTIONS

    • Always connect the inverter to a two pole, three wire mains socket. The socket must be connected to appropriate branch protection ( fuse/ circuit-breaker).
    • Always ensure that the electrical connection to the inverter is properly earthed. Improper earthling might cause unexpected current leakage and prove hazardous.
    • Do not install the inverter in open, excessively humid place or where there is water. Foreign objects or water ingress inside that unit can severely damage the internal components of the inverter.
    • Care should be taken to ensure that the inverter is kept away from direct sunlight and heat emitting appliances. The place of installation should be well ventilated and easily accessible.
    • The inverter does not contain any user serviceable parts inside. Do not attempt to remove the cover the unit. Live main present inside the circuits can render and electric shock.
  1. Electronic Short Ciruit Protection on Batt Mode

    Inverter

SALIENT FEATURES

DATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip inc U.S.A. The Digital Technology used in the product offers High Reliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.

  • MICRO CONTROLLER BASED DESIGN
  • LED/LCD Alphanumeric Display
  • Software controlled CC-CV Charging Technology
  • Smart Multistage Charging with Top-up Pulse Mode
  • Battery status Monitoring and Display
  • Realtime input Main Voitage Monitoring
  • Load Status Display on Battery Mode
  • Smart Overload Sensing with Auto-Restart
  • Electronic Short Ciruit Protection on Batt Mode

SAFETY INSTRUCTIONS

  • Always connect the inverter to a two pole, three wire mains socket. The socket must be connected to appropriate branch protection ( fuse/ circuit-breaker).
  • Always ensure that the electrical connection to the inverter is properly earthed. Improper earthling might cause unexpected current leakage and prove hazardous.
  • Do not install the inverter in open, excessively humid place or where there is water. Foreign objects or water ingress inside that unit can severely damage the internal components of the inverter.
  • Care should be taken to ensure that the inverter is kept away from direct sunlight and heat emitting appliances. The place of installation should be well ventilated and easily accessible.
  • The inverter does not contain any user serviceable parts inside. Do not attempt to remove the cover the unit. Live main present inside the circuits can render and electric shock.

OPERATING MODES OF THE INVERTER

Mains/charging of the mode
The inverter function on Mains Mode when the input AC mains is within the stipulated range from 90V AC to 280 V AC. The charger section starts functioning and continues to boost charge the batteries till the top-up voltage is reached . Thereafter the batteries are pulse charged to maintain optimum battery condition for an extended period of time.The connected loads are fed from input Mains Power. LED status indicator is GREEN. In the LCD models, mains Mode , Charging Mode, Mains input voltage, Battery level percentage etc are sequentially displayed on (16×2) backlit LCD.

Inverter / Backup mode
In the event of brownouts (<90V AC) on High Voltage (>280V AC) or Total Mains Failure(blackouts), the Inverter switches to loads derived from the Batteries. The Inverter keeps on supplying power till  the time the battery gets depleted, in which case the inverter put out an alarm and thereafter shuts off. During invertor Mode, if for any reason the inverter gets overloaded , it trips and then restart after a while. The inverter makes a total of 5 restart attempts. Front panel LED status indicator is RED. In the LCD models, Inverter mode, Battery level percentage, Load level percentage, Input voltage level etc are sequentially displayed on (16×2) backlit  LCD.

REAR PANEL DESCRIPTION

  • Three Pin Mains input Terminal Block for mains input
  • Positive (Red) & Negative (Black) Battery Leads
  • Output Socket for connecting Load
  • Circuit Breaker for Mains Input Protection.

Technical Specification

Input Voltage Range : 90-280 V AC
Low voltage Cut-Off : 90 V AC+ 10 V
High Voltage Cut-Off : 280 V AC + 10 V
Output Voltage (on Mains) : Same as input
Output Voltage (on Batt) : 195-245 V AC
Transfer Time : Within 20 ms
Frequency (on Batt) : 50 HZ + 1%
Charging Current : 10% of Battery Content
Pulse Charging Mode : Auto Top-up Pulse Mode
Mains Mode Overload : Circuit Breaker Trip
Inverter Mode Overload : Electronic Shut Down
Auto Restart Feature : Yes
Inverter short circuit : Electronic Shut Down


    Inverter

SALIENT FEATURES

DATAVISION Digital inverter is based on the latest state-of-the-art embedded Microcomputer technology from Microchip inc U.S.A. The Digital Technology used in the product offers High Reliability, Optimum performance and enhances the life of the batteries and reduces the effort needed for regular maintenance procedures.

  • MICRO CONTROLLER BASED DESIGN
  • LED/LCD Alphanumeric Display
  • Software controlled CC-CV Charging Technology
  • Smart Multistage Charging with Top-up Pulse Mode
  • Battery status Monitoring and Display
  • Realtime input Main Voitage Monitoring
  • Load Status Display on Battery Mode
  • Smart Overload Sensing with Auto-Restart
  • Electronic Short Ciruit Protection on Batt Mode

SAFETY INSTRUCTIONS

  • Always connect the inverter to a two pole, three wire mains socket. The socket must be connected to appropriate branch protection ( fuse/ circuit-breaker).
  • Always ensure that the electrical connection to the inverter is properly earthed. Improper earthling might cause unexpected current leakage and prove hazardous.
  • Do not install the inverter in open, excessively humid place or where there is water. Foreign objects or water ingress inside that unit can severely damage the internal components of the inverter.
  • Care should be taken to ensure that the inverter is kept away from direct sunlight and heat emitting appliances. The place of installation should be well ventilated and easily accessible.
  • The inverter does not contain any user serviceable parts inside. Do not attempt to remove the cover the unit. Live main present inside the circuits can render and electric shock.

OPERATING MODES OF THE INVERTER

Mains/charging of the mode
The inverter function on Mains Mode when the input AC mains is within the stipulated range from 90V AC to 280 V AC. The charger section starts functioning and continues to boost charge the batteries till the top-up voltage is reached . Thereafter the batteries are pulse charged to maintain optimum battery condition for an extended period of time.The connected loads are fed from input Mains Power. LED status indicator is GREEN. In the LCD models, mains Mode , Charging Mode, Mains input voltage, Battery level percentage etc are sequentially displayed on (16×2) backlit LCD.

Inverter / Backup mode
In the event of brownouts (<90V AC) on High Voltage (>280V AC) or Total Mains Failure(blackouts), the Inverter switches to loads derived from the Batteries. The Inverter keeps on supplying power till  the time the battery gets depleted, in which case the inverter put out an alarm and thereafter shuts off. During invertor Mode, if for any reason the inverter gets overloaded , it trips and then restart after a while. The inverter makes a total of 5 restart attempts. Front panel LED status indicator is RED. In the LCD models, Inverter mode, Battery level percentage, Load level percentage, Input voltage level etc are sequentially displayed on (16×2) backlit  LCD.

REAR PANEL DESCRIPTION

  • Three Pin Mains input Terminal Block for mains input
  • Positive (Red) & Negative (Black) Battery Leads
  • Output Socket for connecting Load
  • Circuit Breaker for Mains Input Protection.

Technical Specification

Input Voltage Range : 90-280 V AC
Low voltage Cut-Off : 90 V AC+ 10 V
High Voltage Cut-Off : 280 V AC + 10 V
Output Voltage (on Mains) : Same as input
Output Voltage (on Batt) : 195-245 V AC
Transfer Time : Within 20 ms
Frequency (on Batt) : 50 HZ + 1%
Charging Current : 10% of Battery Content
Pulse Charging Mode : Auto Top-up Pulse Mode
Mains Mode Overload : Circuit Breaker Trip
Inverter Mode Overload : Electronic Shut Down
Auto Restart Feature : Yes
Inverter short circuit : Electronic Shut Down


View Complete Details

Multipurpose CFL Inverter

Ideal for home, shops, party , picnic and camping etc.
Material : High quality ABS plastic bodyHolder: CFL or Bulb holderStrong LED torchUSB Port : Pen drive for music & Mobile Charging through USBDigital FM RadioSMPS Charger of 8 Amp (switch mode power supply)12V 7.2Ah maintenance free dry batteryBattery Charging- 100 Volt To 280 Volt3 Inch High Quality SpeakerLoad: Upto 45 wattsCharging Cut: 14.2 VoltOverload: 60WLow Battery Cut: 9.5 VoltDigital controller base designHigh frequency PWM (pulse-width modulation)Indication: Overload, Charging On , Mains On, UPS On, Low battery, Over load.Supports 4 10W CFL (Not included), Only one CFL is connected, rest three needs to be connected with wires/holdersPlugs : 3 x 2 pin plugsSolar panel input port, you can directly connect external solar panel (not included)Fuse : over load protection fuse (10 Amp)Digital panel buttonsYou can run DC voltage operated mini fanFull function Remote Control2 Pin power cord : 1.5 MeterMinimum 5 hours continues charging required

Note : Specifications are subject to change without notice.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us