Fuorometer

  • RANGE 0 to 0.2, 2, 20 & 200 ppm
  • Primary 366 nm
ilter fluorometer, a light source emits light of an excitation wavelength that is relevant to the compound to be measured. Filter fluorometers produce specific excitation and emission wavelengths by using optical filters. The filter blocks other wavelengths but transmits wavelengths relevant to the compound. The light passes through the sample to be measured, and a certain wavelength is absorbed while a longer wavelength is emitted. The emitted light is measured by a detector. By changing the optical filter, different substances can be measured.
View Complete Details

Filter Based Fluorometer

  • RANGE 0 to 0.2, 2, 20 & 200 ppm (w.r.t. Quinine Sulphate)
  • LIGHT SOURCE Mercury Lamp
  • PEAK TRANSMISSION OF FILTERS  
  • Primary 366 nm
  • Secondary Long pass, Cut-off at 475 & 515 nm
In a filter fluorometer, a light source emits light of an excitation wavelength that is relevant to the compound to be measured. Filter fluorometers produce specific excitation and emission wavelengths by using optical filters. The filter blocks other wavelengths but transmits wavelengths relevant to the compound. The light passes through the sample to be measured, and a certain wavelength is absorbed while a longer wavelength is emitted. The emitted light is measured by a detector. By changing the optical filter, different substances can be measured. Highly sensitive, a full scale reading of 199.9 can be adjusted even with 0.2 ppm of quinine sulphate solution in 0.1 N sulphuric acid & primary filter of peak transmission at 366 nm.
View Complete Details

Water Quality Analyser

PE-138, Microprocessor based Multi Parameter Water Quality Analyser. Measures directly pH, EMF, Temperature, Electrolyte Conductivity (EC), Total Dissolved Solids (TDS), Dissolve Oxygen (DO) & Salinity, Colorimetric, Abs.%T and Turbidity in Water Sample one at a time, Light weight, Portable and Easy to carry on field,

PARAMETER pH EMF (mV) Temp (°C) Salinity
Range 0 to 14 ±1999.9 0 to 100 0 to 40 ppt
Readability 0.001 0.1 0.1 --
Accuracy ±0.001* ±0.1 ±0.5 ±1%(1)
Repeatablility ±0.001 ±0.1 ±0.1 --
INPUT
Sensor CE/GE & RE CE/GE & RE Semiconductor ISE (Cl) & RE
Impedance@25°C >1013 >1013 -- --
Receptacle BNC, Banana BNC, Banana Banana BNC
Temp. Compensation 0 to 100°C A/M -- -- 0 to 50°C A/M
View Complete Details

Hplc Isocratic System

  • SPECTRAL Range
  • 190 to 800 nm Bandwidth
  • 4 nm Readability
  • 0.1 nm Accuracy
  • ± 0.5 nm Repeatability
  • ± 0.2 nm PHOTOMETRIC
  • Range 0 to 3.0 AU
  • Sensitivity Range 0.001 AU to 3.000 AU
  • Readability 0.0001 Abs
  • FLOW CELL Type
  • Analytical Path Length
  • 10 mm Material
HPLC systems are ideal for routine use and quality assurance applications and are perfect for tight spaces and smart budgets. The Variable wavelength UV-VIS Detector features high sensitivity with absorbance ranges from 0 to 3.0 AU. MS Windows based Elichrom software provides complete system control, Data Analysis and multiple reporting options.
View Complete Details

Water Analyzer

Microprocessor based Multi Parameter Water Quality Analyser. Measures directly pH, EMF, Temperature, Electrolyte Conductivity EC, Total Dissolved Solids TDS, Dissolve Oxygen DO & Salinity, Colorimetric, Abs.%T and Turbidity in Water Sample one at a time. Light weight, Portable and Easy to carry on field, Unique DO measurement in Air saturated waters using Conventional Polarographic Probe, Programmable Calibration upto 3 points for pH with Memory Back-up, Userful for Potentiometric & Redox measurements, Accurate & Highly Stable, Elegantly styled into a Briefcase for operational convenience in Field, Operates on Rechargeable Battery & Mains Supply.
View Complete Details

Auto Colorimeter

Long Life LED Light source, Long Life Photo Diode Detector, User friendly operation, Last factors used for C1 and C2 will be stored along with last wavelength and the last scale even on power turn off, Auto Zero Facility, Auto Storage Facility for Concentration, Immune to ambient light variations, Compact, Rugged, Sturdy, Reliable and Easy to Operate, Only 1 ml of sample needed.
View Complete Details

Ion Analyzer

  • Accuracy ±0.001*
  • Repeatability 0.001
  • Range 0 to 14 - 10-9 to 100
Microprocessor based Three Channel Ion Analyser with Printer Interface, Direct measurement of pX (activity), pH, ORP, EMF, Concentration and Temperature, Programmable calibration upto 10 points with Memory Backup, Analysis - by direct & Incremental (Standard & Analyte addition & subtraction) methods, Standard Data Storage Facility, Unit Conversion possible in concentration analysis, Automatic Temperature Compensation, Slope Correction and Asymmetric Potential correction for pH, Pt 100 based Temperature measurement, Open Temperature Sensor Indication, Optional PC Compatibility with RS232C Interface.
View Complete Details

Ion Analyser

  • TEMPERATURE COMPENSATION 0 to 100°C Auto /Manual
  • SENSOR INTERFACE Input Impedance Ω @25°C
  • >10(13) Receptacle
LI-126, Microprocessor based Three Channel Ion Analyser with Printer Interface, Direct measurement of pX (activity), pH, ORP, EMF, Concentration and Temperature. Programmable calibration upto 10 points with Memory Backup. Analysis - by direct & Incremental (Standard & Analyte addition & subtraction) methods.

MODE pH pX(Activity) mV Temp °C Concentration (M)
Range 0 to 14 -2 to +20 ±2000 0 to 100 10-9 to 100
Accuracy ±0.001* -- (1) ±1 ±0.2 --
Repeatability 0.001 0.001 0.1 0.1 --
View Complete Details

LED Based Colorimeter

  • SAMPLE VOLUME Min. 1 ml
  • SAMPLE HOLDER 75 x 12 mm ± 0.5 mm Test tube with 10 mm Path Length
  • HOTOMETRIC RANGE % Transmission
  • 0 to 250 Absorbance
  • -0.31 to 2.0 Abs Repeatability
  • ± 0.01 Abs Readability
  • %T 1
  • Abs 0.01
CL-223, Microcontroller based digital colorimeter, Long Life LED Light source. Long Life Photo Diode Detector. Last factors used for C1 and C2 will be stored along with last wavelength and the last scale even on power turn off. Auto Storage Facility for Concentration. Compact, Rugged, Sturdy, Reliable and Easy to Operate.
View Complete Details

HPLC BINARY SYSTEM

  • SPECTRAL Range
  • 190 to 800 nm Bandwidth
  • 4 nm Readability
  • 0.1 nm Accuracy
  • ± 0.5 nm Repeatability
  • ± 0.2 nm PHOTOMETRIC
  • Range 0 to 3.0 AU
  • Sensitivity Range 0.001 AU to 3.000 AU
  • Readability 0.0001 Abs
  • FLOW CELL Type
  • Analytical Path Length
  • 10 mm Material
The Variable wavelength UV-VIS Detector features high sensitivity with absorbance ranges from 0 to 3.0 AU. High performance Pulse free pump with low dead volume diaphragm type pulse damper. Easy exchange of the Flow cells, Injection loops allows using the system for all applications between Micro upto preparative HPLC.