Post Buy Requirement
GE
Pune, Maharashtra, India
Add Review

Laboratory Apparatus #5814019

PARTICLE CHARGE APPARATUS

Particle charge apparatus As per IS 8887, Anex:'E":
Use:For measuring the cationic or anionic nature of the bituminous products.
Description:Unit consists of battery, rheostat, milliammeter, 2 - SS electrode plates, glass container, illumination for the chamber, timer device (all provided in required / specified dimensions and parameters). Mains / battery operated. The instrument is well illuminated with fluorescent lamp for better view of sample &deposition on SS plate. It operates on 12vsupply either on mains or battery through ON/OFF switch. Digital power supply gives current greater than 4mA. A mechanical timer of 30Minutes Rating helps to set Time duration of deposit.
ONE SPECIAL DIGITAL LED TO JUDGE ANIONIC/CATIONIC WITH OUT CLEANING/OBSERVATION OF SS PLATES

View Complete Details

Automatic Flash Point Apparatus

Theflash pointis the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite. To determine thefire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s. This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.
Its primary use is for viscous materials having a flash point below79C (175F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment for temperature range up to 400*C.


For substances with unknown flash points, theAPPARATUShas a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.
Optional On demand:When examining highly viscous specimens, a preheating time and temperature are set, in order to warm-up and liquefy the sample & to insert temperature sensor probe without problem. Further a skimmer is provided for removing the surface skin from bituminous samples.
The UNIT is equipped with:Standard Cup:with handle, made of brass
Temperature Probe Pt-100:for sample temperature
Battery operated (1.5V pencil type cell) Gas Igniter:for LPG gas ignition (Manually operated)
Flame Detection Unit:for the detection of flash- and fire-points by UVsensor.
Heating:By electrical SS Tubular Cartridge Heater of suitable rating to maintain ramp rate & easily replaceable.
Flame Arrest Coverfor extinguishing the fire in the cup
DC Motors:Flame movement, LID Open/Close, Assembly of sensor RTD(Pt-100 thermocouple) Up/Down mechanism
PC Interface Programmed Controller
The Unit is incorporated with MODBUS RTU PC interface Microprocessor based PID Programmable controller user friendly features. (PC operated system through RS232 cable connection as option at extra cost)

Specification & Features:
Automatic Flash and Fire point apparatus (By Cleveland Open Cup Method).
Temp.Range: Ambient to 400C with RTD sensor as Thermocouple.
Flame-Detector: UV based flame-detector sensor & Controller.
DC motors: Flame movement, LID Open/Close, Assembly of sensors Up/Down mechanism.
Controller: Microprocessor based Programe process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and DC V SSR as o/p.
Equipment Overall Size (LxWxH): 24x14x31
Equipment Gross Weight: 21 Kg.
Supply: 230 V, 1-, 50 Hz supply with proper earthing system for Controller.

View Complete Details

VSP/VHD Apparatus

VICAT SOFTENING TEMP. (ASTM D1525)

Determination of the temperature at which a standard indenter penetrates 1mm into the surface of a plastics test specimen under one of the loads specified under uniform rate of heating.

Rate of rise of temp. 50 + 50C / per hr. 120 + 120C


DEFLECTION TEMPERATURE OF PLASTIC UNDER FLEXURAL LOAD ( As per ASTM D-648)

Determination of temp. at which an arbitrary deformation occurs when plastics are subjected to arbitrary bending loads and conditions of continually rising temperature Rate of rise of temp. 2 + 0.20C / per min

View Complete Details

Environmental Stress Cracking Resistance Apparatus

  • Resolution 0.10 °C
  • Max. Temperature 1500 °C
  • Max. Temperature - R.T.,

E.S.C.R. Apparatus is used for determination of susceptibility of ethylene plastics to environmental stress cracking when subjected to certain conditions. Bent specimens of the plastics each having a controlled imperfection on the surface are exposed to the action of a surface active agent, oils or detergent. The proportion of the total number of specimens that crack in a given time is observed.



Inside bath is of S. S. and outside bath in M. S. with heat insulation.

The heating system is having a RTD, Heater and Digital Temp. Controller (PID)

View Complete Details

Flash And Fire Point Apparatus

  • Temperature range: +79°C to +400°C
  • Supplied with: 1 cup with handle, 1 thermometer

User:Bitumen, Insulating Oil, Lube Oil, Power Plant, Engine Oil, Hydraulic
Fluid, Turbine Oil, Jet Lube, Regulatory Authorities
This flash-point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.
Its primary use is for viscous materials having a flash-point between 79C (175F) and 400C (752F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash-point is approached.
At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
The flash-point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite.
To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.
Manual Flash- & Fire-Point Tester, Cleveland Method Consisting of: special tripod stand, heating collar, insulating board, spl rubber tubing , hose connection, universal gas merker burner, thermometer holder

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gatha Enterprises (Gatha Enterprises)
  • Snehdeep, Chintamaninagar, Sahakarnagar − 2, , Chintamani Nagar, Pune, Maharashtra - 411009
  • Share us via
Retailer of Laboratory Apparatus from Pune, Maharashtra by Gatha Enterprises
Post Buy Requirement
GE
Pune, Maharashtra, India
Add Review

Laboratory Apparatus #5814019

PARTICLE CHARGE APPARATUS

Particle charge apparatus As per IS 8887, Anex:'E":
Use:For measuring the cationic or anionic nature of the bituminous products.
Description:Unit consists of battery, rheostat, milliammeter, 2 - SS electrode plates, glass container, illumination for the chamber, timer device (all provided in required / specified dimensions and parameters). Mains / battery operated. The instrument is well illuminated with fluorescent lamp for better view of sample &deposition on SS plate. It operates on 12vsupply either on mains or battery through ON/OFF switch. Digital power supply gives current greater than 4mA. A mechanical timer of 30Minutes Rating helps to set Time duration of deposit.
ONE SPECIAL DIGITAL LED TO JUDGE ANIONIC/CATIONIC WITH OUT CLEANING/OBSERVATION OF SS PLATES

View Complete Details

Automatic Flash Point Apparatus

Theflash pointis the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite. To determine thefire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s. This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.Its primary use is for viscous materials having a flash point below79C (175F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment for temperature range up to 400*C.

For substances with unknown flash points, theAPPARATUShas a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.
Optional On demand:When examining highly viscous specimens, a preheating time and temperature are set, in order to warm-up and liquefy the sample & to insert temperature sensor probe without problem. Further a skimmer is provided for removing the surface skin from bituminous samples.
The UNIT is equipped with:Standard Cup:with handle, made of brass
Temperature Probe Pt-100:for sample temperature
Battery operated (1.5V pencil type cell) Gas Igniter:for LPG gas ignition (Manually operated)
Flame Detection Unit:for the detection of flash- and fire-points by UVsensor.
Heating:By electrical SS Tubular Cartridge Heater of suitable rating to maintain ramp rate & easily replaceable.
Flame Arrest Coverfor extinguishing the fire in the cup
DC Motors:Flame movement, LID Open/Close, Assembly of sensor RTD(Pt-100 thermocouple) Up/Down mechanism
PC Interface Programmed Controller
The Unit is incorporated with MODBUS RTU PC interface Microprocessor based PID Programmable controller user friendly features. (PC operated system through RS232 cable connection as option at extra cost)

Specification & Features:
Automatic Flash and Fire point apparatus (By Cleveland Open Cup Method).
Temp.Range: Ambient to 400C with RTD sensor as Thermocouple.
Flame-Detector: UV based flame-detector sensor & Controller.
DC motors: Flame movement, LID Open/Close, Assembly of sensors Up/Down mechanism.
Controller: Microprocessor based Programe process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and DC V SSR as o/p.
Equipment Overall Size (LxWxH): 24x14x31
Equipment Gross Weight: 21 Kg.
Supply: 230 V, 1-, 50 Hz supply with proper earthing system for Controller.

View Complete Details

VSP/VHD Apparatus

VICAT SOFTENING TEMP. (ASTM D1525)

Determination of the temperature at which a standard indenter penetrates 1mm into the surface of a plastics test specimen under one of the loads specified under uniform rate of heating.
Rate of rise of temp. 50 + 50C / per hr. 120 + 120C

DEFLECTION TEMPERATURE OF PLASTIC UNDER FLEXURAL LOAD ( As per ASTM D-648)

Determination of temp. at which an arbitrary deformation occurs when plastics are subjected to arbitrary bending loads and conditions of continually rising temperature Rate of rise of temp. 2 + 0.20C / per min

View Complete Details

Environmental Stress Cracking Resistance Apparatus

  • Resolution 0.10 °C
  • Max. Temperature 1500 °C
  • Max. Temperature - R.T.,

E.S.C.R. Apparatus is used for determination of susceptibility of ethylene plastics to environmental stress cracking when subjected to certain conditions. Bent specimens of the plastics each having a controlled imperfection on the surface are exposed to the action of a surface active agent, oils or detergent. The proportion of the total number of specimens that crack in a given time is observed.


Inside bath is of S. S. and outside bath in M. S. with heat insulation.

The heating system is having a RTD, Heater and Digital Temp. Controller (PID)

View Complete Details

Flash And Fire Point Apparatus

  • Temperature range: +79°C to +400°C
  • Supplied with: 1 cup with handle, 1 thermometer

User:Bitumen, Insulating Oil, Lube Oil, Power Plant, Engine Oil, Hydraulic
Fluid, Turbine Oil, Jet Lube, Regulatory Authorities
This flash-point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.
Its primary use is for viscous materials having a flash-point between 79C (175F) and 400C (752F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations. The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash-point is approached.
At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
The flash-point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite.
To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.
Manual Flash- & Fire-Point Tester, Cleveland Method Consisting of: special tripod stand, heating collar, insulating board, spl rubber tubing , hose connection, universal gas merker burner, thermometer holder

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Gatha Enterprises (Gatha Enterprises)
  • Snehdeep, Chintamaninagar, Sahakarnagar − 2, , Chintamani Nagar, Pune, Maharashtra - 411009
  • Share us via