Post Buy Requirement
HS
Chennai, Tamil Nadu, India
Add Review

Our Product / Services

  1. Sensors 3 Products available
  2. Security Alarms & Devices 4 Products available
  3. Electronic Detectors 6 Products available
  4. Fire Extinguisher 13 Products available
  5. CCTV Camera 6 Products available
  6. Photography Equipment & Supplies 3 Products available
  7. Control Panels 3 Products available
  8. Signs 3 Products available
  9. Fire Fighting & Protection 4 Products available
  10. Others 57 Products / Services available

Other Products / Services #330548

Attendance Access Control Systems

  • Operating Temperature -20°C ~ 50°C,
  • Authentication Modes Finger/ Card,
  • Fingerprint Sensor, 500 dpi optical sensor,
  • Face Detection Camera N/A,
  • Card Options 125KHz EM 13.56MHz Mifare/DesFire,
  • Template Capacity 10, 000 (1
  • Max. User 50, 000
  • Log Capacity, 50, 000
  • TCP/IP Yes (optional) Rs 485
  • Wiegand, configurable upto 64 bits,
  • Ttl I/O 2 Input,
  • Built-In Relay 1,
  • CPU 400 MHz DSP,
  • Memory 4 GB flash + 8 MB RAM,
  • Led Indicator Multi-color,
  • Sound Indication Multi-tone buzzer,
  • Tamper Switch,
  • Operating Voltage 12V DC,
  • Dimensions (W X H X D, MM) 50 x 160 x 37
View Complete Details

CO2 VALVE Type Extinguisher

We've seen how, in just a matter of seconds, a small fire can grow into a lethal blaze. If you've missed that time window, there's still hope.

Ceasefire's CO2 valve type extinguishers are bigger, pack in tremendous power and are very effective in putting out larger fires.Ceasefire's CO2 valve type extinguishers are available in three variants, with more storage capacity than the regular CO2 extinguisher.

Extremely user friendly, with a protective cover over the valve to avoid the risk of freeze burn, Ceasefire's CO2 valve type extinguishers are the perfect weapon against large, hard to fight B and C Class fires.

View Complete Details

Hammer Drill

Ceasefire brings to you Ceasefire Lancepro. Ceasefire Lancepro is arevolutionary fire fighting system that comes to address some of the biggest challenges faced by anyone fighting a blaze in a building complex.Lancepro can also be used directly in case of open fire, whilst maintain a safe distance from the blaze and protecting the goods from collateral damage.

The innovative Ceasefire Lancepro uses Watermist technology enabling it to be used safely on all types of fires including electrical
fires. Water in mist form also increases the surface area of water many times over facilitating heat absorption and taking the firefighting
power manifold by rapidly bringing down the temperature to below combustible levels and cutting off the oxygen supply.

Having a drill machine along in the Lancepro kit makes it convenient for the fire fighter to douse off the fire in an enclosed area without physically coming in contact with it. A small orifice is all you need to ensure the security of the fire fighter who can quench the fire without actually entering the enclosed space. The drill comes with two bits one for drilling in concrete surface and another for metal surface drilling. Once the opening is made by the drill unit of Lancepro the watermist gun is inserted through the opening and watermist is discharged.The two types of guns specialize in administering watermist into the fire zone from a horizontal (from the wall) and vertical
(from the roof) angle, respectively.

View Complete Details

Basic Security Kit

Contrary to popular belief, most burglaries are not random, unplanned acts. In most cases, the burglar is someone who has observed you over time: a former household help or even your ex-watchman could be a potential threat.

He knows your property, the people in it and in many cases, their routine. As for your valuables, every experienced burglar knows where to find them: drawers, cupboards and safes.

So how can you protect yourself against even the most calculated attack?

With Ceasefires security system you can leave your home confident that a break-in will automatically sound an alarm, activate a response, and inform you via your telephone.

Motion detectors, wired siren, magnetic contacts and curtain detectors alert you the second an intruder breaks in. Flood and smoke detectors alert you in case of flooding and fire. And the central control panel monitors the overall security of your home. This system leaves no corner unguarded.

View Complete Details

Basic Panel

  • Dimension: (250 x 190 x 44 mm).
  • Humidity: 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range: -4°F to 140°F (-20°C to 60°C)
  • Weight: 1050 gms

Contrary to popular belief, most burglaries are not random, unplanned acts. In most cases, the burglar is someone who has observed you over time: a former household help or even your ex-watchman could be a potential threat.

He knows your property, the people in it and in many cases, their routine. As for your valuables, every experienced burglar knows where to find them: drawers, cupboards and safes.

So how can you protect yourself against even the most calculated attack?

With Ceasefires security system you can leave your home confident that a break-in will automatically sound an alarm, activate a response, and inform you via your telephone.

Motion detectors, wired siren, magnetic contacts and curtain detectors alert you the second an intruder breaks in. Flood and smoke detectors alert you in case of flooding and fire. And the central control panel monitors the overall security of your home. This system leaves no corner unguarded.



Number of Zones:29 wireless, 1 hardwired (zone No. 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior, perimeter, delay 1, delay 2, 24 hours - audible, 24 hours - silent, fire, non-alarm and emergency.
User Codes:8 codes, 4 digits each
Data Retrieval:Status, alarm memory, trouble, event log.
Real Time Clock: The control panel keeps and displays time and date.
Compliance with U.S Standards:Meets FCC Part 15 and Part 68 requirements.
Compliance with European Standards:EN 50131-1 Grade II Class II
EMC Emission:EN 50081-1 1992
RFI:EN55022 1998
EMC Immunity:EN 50082-1 1997
EMC Immunity to Conducted RF:EN6100-4-6 1996
Telephony:Telephony: TBR21 1998
Safety:EN60950+ Am1(93), Am2(93), Am3(95), Am4(97)
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Coding:PowerCode and/or CodeSecure
Power Supply :Plug-in transformer.230 VAC, 50 Hz / 9 VAC, 700 mA or 230 VAC, 50 Hz /9 VAC, 1A.
Current Drain:Approx. 95 mA standby, 500 mA at full load and in alarm.
PGM (auxiliary)
Output Current:100 mA max.
Sounder Output Current with 700 mA Transformer :Internal sounder: 50 mA maxExternal sounder:150 mA max
Sounder Output Current with 1A Transformer:Internal sounder: 50 mA max / External sounder: 350 mA max.
Fuse Rating:0.5 A for siren / sounder circuit protection.
Backup Battery :(provides power for at least 4 hours) Option - 7.2 V Nickel-Metal rechargeable battery pack, 1300 mAh.
Built-in Modem:300 baud, Bell 103 protocol
Data Transfer to Local Computer:Via RS232 serial port
Report Destinations: 2 central stations, 4 private telephones
Reporting Format Options:SIA, Pulse 4/21900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Pulse Rate: 10, 20, 33 and 40 pps programmable
Message to Private Phones:Tone or voice
Message to Pager:PIN No. * Alarm Type * Zone No.
Operating Temp. Range:32F to 120F (0C to 49C)

View Complete Details

Magnetic Contact Switch

  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Dimensions 81 x 23.5x32.5 mm
  • Weight 34 gms
  • Magnet 13 gms
  • Resistor Required 47 kΩ,
  • Power Source 3.6 V Lithium battery

Transmitter's ID Code:24-bit digital word, over 16 million combinations, pulse width modulation.
Overall Message Length:36 bits
Alarm Inputs:Alarm Inputs: 2, one internal and one external, with a separate 24-bit transmitter ID each.
Auxiliary Input Circuit Type:N.C. / E.O.L., selected with DIP switch, E.O.L.

View Complete Details

One Way Key Fob

  • Dimensions 53.5 X 31.5 X 12.5 MM
  • Weight (including battery) 21 gms
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Battery Life Expectancy 1 year (for typical use)
  • Modulation Ask (ON-OFF keying)
  • Power Supply 12 V alkaline battery


Battery Supervision


Good battery - LED lights steadily upon transmission /Low attery - LED flickers upon transmission



Coding


28-bit ID, 4-bit function code and 32-bit rolling code



Transmission Duration


Each button press causes transmission for upto 2 seconds

View Complete Details

Oval Pet Motion Detector

  • Detector Type Dual element low noise pyroelectric sensor.
  • No. of Curtain Beams 9
  • Max. Coverage 12 x 12 m (40 x 40 ft) / 90°
  • Pet Immunity Up to 38 kg (85 lb).
  • Standby Current Drain Approx. 0.025 mA.
  • Nominal Battery Capacity 1450 mA/h.
  • Weight 70 gms.

Internal Battery:3V Lithium battery, type CR-123A. For UL installations, use Panasonic or Sanyo only.



Transmit Current Drain:20 mA (including LED).



Battery Life (with LED on):Typically over 3 years.



True Motion Event Verification:2 position selector - 1 (OFF) or 2 (ON) motion events.



Alarm Period:3 seconds.



Rearm Timer:Rearms the detector 2 minutes after the last alarm.
Timer disabled in the walk test mode not applicable for the DD243 version (see section 1).



Transmission Sequence:3 data bursts at variable intervals within 3 seconds.



Encoding:24-bit ID, over 16 million possible combinations. Total.



Message Length:36 bits.



Tamper Alert:Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored.



Supervision Message: Signaling at 60 minutes interval (U.S. version)
15 minute interval (UK version) or according to local standards.



Height:1.8 - 2.4 m (6 - 8 ft). Recommended height up to 2.1 m (7 ft)
Installation Options:Surface or corner



BR-1:Surface mounted swivel bracket, adjustable 30 down and 45 left/45 right, BR-1 with a corner adapter, BR-1 with a ceiling adapter



RFI Protection:>20 V/m up to 1000 MHz.



Operating Temperatures:-10C to 50C (14F to 122F).



Storage Temperatures:-20C to 60C (-4F to 140F).



Compliance with Standards:Designed to meet FCC Part 15 and Directive 1999/5/EC of the European Parliament.



Dimensions (H x W x D):94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16).

View Complete Details

Rectangular Pet Motion Detector

  • Weight 92 gms without bracket, 107 gms with bracket.
  • Dimensions (H x W x D) 117 x 65 x 47 mm.
  • Storage Temperatures 20°C to 60°C (-4°F to 140°F).
  • Operating Temperatures -10°C to 50°C (14°F to 122°F).
  • RFI Protection >30 V/m up to 1000 MHz.
  • Height Up to 2.4 m (8 ft)

Max. Coverage Range


12 x 12 m (40 x 40 ft) / 90.



Pet Immunity


Animals up to 36 kg - not verified by UL.



Vertical Adjustment


3-position adjustment scale: 1.8 m (6 ft), 2.1m (7 ft) and 2.4 m (8 ft).



Internal Battery


3V Lithium battery



Nominal Battery Capacity


750 mAh



Standby Current Drain


0.015 mA



Transmit Current Drain


20mA (including LED)



True Motion Event Verification


2 position selector - 1 (OFF) or 2 (ON) motion events.



Alarm Period


3 seconds



Transmission Sequence


3 data bursts at variable intervals within 3 seconds.



Encoding


24-bit ID, over 16 million possible combinations.



Total Message Length


36 bits.



Height


Up to 2.4 m (8 ft)



Bracket Adjustment


20 downward (only in non-pet immune applications), 20 left and right

View Complete Details

Curtain Detector

  • Dimensions (H x W x D) 105 x 35 x 30 mm
  • Weight 60 gms
  • Storage Temperature -20°C to 60°C (-4°F to 140°F).
  • Operating Temperature -10°C to 50°C (14°F to 122°F).
  • Mounting Height 1.8 - 2.4 m (6 - 8 ft).
  • Total Message Length 36 bits.

Detector Type


Dual-element low noise pyroelectric sensor.



Range Settings


Long (6 m), Medium (4 m) and Short (2 m).



Internal Battery


3V Lithium battery



Nominal Battery Capacity


1450 mA/h.



Microprocessor


8-bit, low power CMOS.



Alarm Period


Approx. 3 seconds.



Rearm Timer


Rearms the detector 2 minutes after the last alarm.



Transmission Sequence


3 data bursts at variable intervals within 3 Seconds.



Encoding


24-bit ID, over 16 million possible combinations.

View Complete Details

Repeaters

  • Dimensions (H x W x D) 110 x 63 x 25
  • Weight 73 gms
  • Operating Temperature 0 °C to 49°C (32° F to 120° F).
  • LED indicator Lights during transmission.
  • Modulation Type 100% ASK.
  • Power Input Ranges 13 - 20 VDC, or 11 - 16 VAC, 100 mA min.

Compliance with Standards


Meets FCC Part 15, MPT 1340 and directive 1999/5/EC



Backup Battery


9 V-style rechargeable Ni-Cd or Ni-MH. Battery Backup Duration (with fully charged 120 mA/h battery and 1:1 standby/transmit ratio): 2 hours (315 and 433.92 MHz units)

View Complete Details

Flood Detector

  • Weight (including battery) 45gms
  • Dimensions 81 x 23.5x32.5 mm
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Weight of Flood Sensor Cable Approx 60 gms
  • Length of Flood Sensor Cable 3 meters
  • Nominal Battery Capacity 750 mAh

Transmitter's ID Code


24 bit digital word, over 16 million combinations, pulse width modulation.



Overall Message Length


36 bits
Message Repetition


One-shot transmission (default) or once every 3 minutes (selectable)



Power Source


3V Lithium battery



Current Drain


6A STBY, 17mA average in operation (including LED

View Complete Details

Wireless Pendant

  • Color White.
  • Power Supply 12-volt alkaline battery
  • Dimensions 32 x 57 x 16 mm
  • Weight 22 Gms
  • Operating Temperature 0° to 49°C (32° to 120°F).

Encoding


24-bit digital word, over 16 million combinations.



Transmission duration


As long as the button is kept pressed.

View Complete Details

Wrist Transmitter

  • Color: Black (Purple button)
  • Weight: 25 Gms
  • Dimensions: 35 mm (1.4 in.).
  • Operating Temperature: 0° to 50°C (32° to 122°F).
  • Nominal Battery Capacity: 150 mAh
  • Power Supply: 3-volt Lithium cell

Modulation


ASK (ON-OFF keying)



Transmitter ID


24-bit digital word, over 16 million possible code combinations, pulse width modulation.



Total Message Length 36 bits


Minimum Transmit Duration2 sec
Power Supply:3-volt Lithium cell

View Complete Details

Glass Break Detector

  • Weight 130 gms
  • Dimensions 80 x 108 x 43 mm
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Tempered 3.2 to 6.4 mm (1/8 to 1/4")
  • Plate 2.4 to 6.4 mm (3/32 to 1/4")
  • Wired 6.4 mm (1/4")

Microphone:Omni-directional electret
Alarm Duration:4 seconds
RF immunity: 20 V/m, 1 MHz to 1000 MHz
Temperature range: -10 to 50C (14 to 120F)
Minimum:0.3 x 0.6 m (1 x 2') or larger glass thickness
Plate:2.4 to 6.4 mm (3/32 to 1/4")
Tempered:3.2 to 6.4 mm (1/8 to 1/4")
Wired:6.4 mm (1/4")
Laminated:3.2 to 6.4 mm (1/8" to 1/4")
Transmitter's ID Code:24-bit digital word, over 16 million combinations, pulse width modulation.
Overall Message Length:36 bits
Response to Tamper Event:Tamper report every 3 minutes (until the tamper switch is restored).

View Complete Details

Wireless Pro Panel System

  • Weight 1600 g ms
  • Dimension 285 x 215 x 55 mm
  • Humidity 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range -4°F to 140°F (-20°C to 60°C)
  • Operating Temp. Range 14°F to 120°F (-10°C to 49°C)
  • Message to Private Phones Tone or voice

Zones Number:28 wireless, 2 hardwired (zones 29 & 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
Display:Single line, Backlit 16-character LCD.
Alarm Types:Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
Siren Signals:Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse. (fire).
Siren (bell) Timeout:Programmable
InternalSounder Output:At least 85 dBA at 10 ft (3 m)
Supervision:Programmable time frame for inactivity alert
Data Retrieval:Status, alarm memory, trouble, event log.
Compliance with U.S. Standards:Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC C1023.
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Antenna Type:Spatial diversity
Coding:PowerCode and/or CodeSecure
Power Supply:Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
Maximum Output Ripple:0.05
Current Drain: Approx. 40 mA standby, 1400 mA at full load and in alarm.
Site External Siren Current (EXT):450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
Site Internal Siren Current (INT):450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
PGM Output Current:100* mA max.
Wired Detectors (zones 29 & 30)
Total (Sum) Current: 36* mA max.
High Current / Short Circuit Protection: All outputs are protected (automatic reset fuse).
Total Pro Panel output current: 550 mA.

View Complete Details

Wireless Camera

  • Resolution 320 * 240 image resolution
  • Certification CE and FCC
  • Lens Type Board Lens
  • Focus Lens 20 cm from infinity.
  • Image sensor CMOS (complementary metal oxide semiconductor)
  • Power Powered by AC wall outlet
View Complete Details

Remote Commander

  • Battery 3 VDC, Lithium battery.
  • Weight 130Gms
  • Current Consumption 10 μA approx. (STBY),
  • Back light illumination Selectable on/off.
  • Dimensions (HxWxD) 127 x 72 x 24 mm
  • Operating Temperatures 0° to 49°C (32° to 120°F)

95mA (in transmission, including LED and back light currents).

View Complete Details

KEYPAD Control System

  • Nominal Voltage 12 VDC
  • Display LDC graphical display 128 × 64 pixels
  • Display Viewing Area (mm) 60.0 × 32.5
  • Case Colour Light grey
  • Dimensions (mm) 147W × 144H × 29D
View Complete Details

DIN Rail Switch

  • Supply Voltage 230V +10% -15% 50 Hz
  • Supply Current ≤ 20 mA capacitive
  • Making Capacity - 2000 W ( incandescent lamp) - 3 A (motors) - 16 A (resistive loads)
  • EMC Emission A ccording to EN 50081-1
  • EMC Immunity A ccording to EN 50082-1
  • Electrical Safety A ccording to EN 60950 1 and EN 60065
  • Signal Sensitivity 5 mVpp min 50 mVp max at 120 kHz
  • Input Impedance ≥ 180 Ohms (L - N) at 120 kHz
  • Connections S crew type terminals for phase, eutral, switched phase,  
  • Dimensions 81 x 23.5x32.5 mm
  • Ambient Temperature 10° C to + 40° C (operation) - 20° C to + 70° C 
View Complete Details

Night Box Camera

  • Sensor 1/3" SONY Vertical Double Density Interline CCD
  • Total Pixels NTSC=811(H) * 508/(V) / PAL=795(H) * 595(V)
  • Effective Pixels NTSC=768(H) * 494(V) / PAL=752(H) * 582(V)
  • Scanning System 2
  • Synchronization Internal
  • O.S.D Built-in
  • Dynamic Range 52dB
  • Backlight WDR / BLC / OFF Selectable
  • Resolution 560TV Lines
  • S/N (Y signal) 52dB
  • Minimum Illumination 0.001Lux (Sens-Up * 128X)
  • White Balance ATW / AWC / Manual / Outdoor / Indoor
  • Electronic Shutter Speed AUTO(NTSC=1/50sec ~ 1/100, 000sec 
  • Sense-Up AUTO (Selectable limit x2 ~ x256) / OFF
  • Gain Control HIGH / LOW / OFF Selectable
  • DNR OFF/ON (1~32 Level Adjustable)
  • Motion Detection ON/OFF (8 Zone, ALARM Output)
  • Privacy ON/OFF (8 Programmable Zones)
  • Mirror(H-REV) ON/OFF
  • FLIP(V-REV) ON/OFF
  • Sharpness ON/OFF (Level Adjustable)
  • D&N Selection COLOR / BLACK & WHITE / AUTO / EXTERNAL
  • DIS ON/OFF
  • Digital Zoom ON (0 ~ 230 Level Adjustable) / OFF
  • Communication RS-485 (Pelco-D Protocol)
  • Power DC 12V
  • Power Consumption 120mA
  • Lens C&CS Mount(Lens Option)
  • Operating Temperature/Humidity -10°C to +50°C. RH 95% Max.
  • Storage Temperature/Humidity -20°C to +60°C. RH 95% Max.
  • Dimension 58mm(W) * 52mm(H) * 123mm(D)
  • Weight 350g
View Complete Details

Digital Video Recorders

  • Weight 2500 gms
  • Sensor/Relay/PTZ interface Sensor input(4Ch), Relay output(1Ch)
  • HDD Capacity 1 SATA HDD Back up
  • Network xDSL, Cable Modem, LAN(Ethernet 10/100 base-T)
  • Power Supply DC 12V/5A
  • Power Consumption 25W
  • Operating Temperature 5°C to 40°C
  • Dimensions 250(W) X 65(H) X 155(D)mm

Video Mode: NTSC/PAL

O/S: Embedded Linux

Compression:Standard H.264 / ADPCM(Audio)

Video Input: 4Ch

Video Output:Monitor(1 BNC, 1 VGA)

[Speed] Live Display (NTSC/PAL):120fps/100fps

[Speed] Recording (NTSC/PAL):120fps/100fps

Recording Resolution (NTSC/PAL):Full (720 X 480)/Full (720 X 576), Field (720 X 240)/Field (720 X 288), CIF (352 X 240)/CIF (352 X 288)

Live Display:1/4/Sequence

Recording mode:Auto, Continuous, Motion, SensorAudio:Input (1Ch), Output (1Ch)

View Complete Details

Motion Sensor Lights

  • Operating Voltage ~220-240V / 50 Hz
  • Lighting Load 2x25W
  • E27 Akkor Lamp Detection Angle 360°Detection Height
  • Detection Range 8 m.
  • Dia Time Adjustment 10 sec ~5min
  • Daylight Adjustment Yes
  • Operating Temperature -20°C to +40°C
  • Protection Class IP20
  • Standard Compliance TS EN 60669-2-1 ve TS EN 60598-2-1
View Complete Details

Led Sensor Light

  • Operating Voltage ~220-240V / 50 Hz,
  • Lighting Load 2x25W E27 Lamp,
  • Detection Angle 360°,
  • Detection Height 2.8 m.,
  • Detection Range 9 m. Diameter
  • Time Adjustment 10 sec ~5min,
  • Daylight Adjustment Available,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP20,
  • CE & Rohs Compatible Yes
View Complete Details

Emergency Light

  • OPERATING VOLTAGE ~220-240V / 50 Hz
  • LIGHTING LOAD 2x25W E27 Lamp
  • DETECTION ANGLE 360°
  • DETECTION HEIGHT 2.8 m.
  • DETECTION RANGE 9 m. Dia
  • TIME ADJUSTMENT 10 sec ~5min
  • BATTERY TYPE 1x9V 200mAh NiMh Square Battery
  • BATTERY CHARGE TIME 5 hour one battery 10 hour double battery
  • BATTERY DICHARGE TIME 1-7 hour one battery 2-14 hour double battery
  • DAYLIGHT ADJUSTMENT Yes
  • OPERATING TEMPERATURE -20°C to +40°C
  • PROTECTION CLASS IP20
  • STANDARD COMPLIANCE TS EN 60669-2-1 ve TS EN 60598-2-1
  • ROHS Compatible
View Complete Details

Wall Mounted Light

  • Operating Voltage ~220-240V / 50 Hz,
  • Lighting Load 1x60W,
  • Detection Angle 180°,
  • Detection Height 2.8 m.,
  • Detection Range 3m. - 12m.,
  • Time Adjustment 10 sec ~5min,
  • Sensitivity Adjustment Yes,
  • Daylight Adjustment 5-1000 LUX,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP44,
  • CE Yes,
  • Standard Compliance TS EN 60669-2-1 ve TS EN 60598-2-1,
  • Dimensions (mm) 220x280x95 mm,
  • Box Weight 16.5 kg, Box Dimensions
  • Piece Per Package 8 Pcs,
  • Rohs Compatible
View Complete Details

Door Guard

  • Certification CE
  • Holding Force 280 Kg and 500 Kg (both are available),
  • Current Drawn 480 mA at 12 VDC and 240 mA and 24 VDC ,
  • Weight 2 Kg ,
Any intruder trying to break through a door guarded by an EM Lock will find themselves pitted against a holding force of 600lbs. This magnetic lock works on a current of 480mA at 12VDC and is impossible to open by force.

View Complete Details

Boundary Guard Post

  • Coverage 24m (12m on each side),
  • Power Supply 3 - 9VDC lithium or alkaline battery,
  • Operating Temperature –20°C - + 50°C,
  • Weight 520 g,
  • Detection Zones 4 Zones (2 zones on each side),
  • Sensitivity 2.0°C at 0.6m/sec,
  • Detectable Speed 0.3m – 1.5m/s,
  • Current Consumption 3mA(Walktest, LED on) 15uA(Standby),
  • Alarm Period 2 ± 1 sec,
  • Alarm Output Form C-Solid state switch
  • Battery Saving Time Approx. 120 sec. or 5 sec.,
  • Tamper Switch Form C opens when cover is removed,
  • Warm-Up Period Approx. 2 min.,
  • Led Indicator Disable during normal operation & Enable during walk test or LED switch on,
  • Environmental Humidity 95% max.,
  • Rf Interference No Alarm 20V/m,
  • Mounting Height 0.8m – 1.2m,
  • Mounting Wall,
  • Weatherproof IP55
View Complete Details

Gas Leak Detector

  • Operating Voltage 9V DC,
  • Response Time 30s,
  • Gas Sampling Natural diffusion,
  • Alarming Method Visual and audiable,
  • Alarm Sound 85dB,
  • Sensor Life Approx. 5 Years,
  • Weight about 420 g,
  • Dimensions (L × W × H) 170 × 100 × 45 mm,

Alarming Level :50 ppm between 60 to 90 mins 100 ppm between 10 to 40 mins 300 ppm less than 3 mins,

View Complete Details

Staircase Light Timer

  • Operating Voltage 230-240VAC /50Hz,
  • Lighting Load 2200W for E27/800W for Flo.,
  • Time adjustment 6sec-6min.,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Video Distributor

  • Video Distribution From the junction Points,
  • Operating Voltage From Central Unit,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Guard Telephone Handset

  • LCD Digital LCD screen,
  • Operating Voltage From Central Unit,
  • Name List Yes,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Multi System Video Power Supply

  • Relay Outputs 3 door lock relay output,
  • Power Supply Switch Mode power supply,
  • Operating Voltage 85-265 VAC (50-60 Hz),
  • Output Voltage 24V DC,
  • Current 3.5A,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Apartment Door Camera

  • Camera Color,
  • Operating Voltage From Central,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Downlights

  • Case Color Ivory
  • Operation Time 1h to 3h
  • Material Fire resistant ABS plastic
  • Dimensions (mm) 99.7 * 50H
View Complete Details

STEP LUMINAIRE

  • Material Fire resistant PC +ABS plastic (FR3010)
  • Fire class UL94V-O
  • Operation TIME 1h / 3h
  • Dimensions (MM) 80Wx80Hx12D

Ceasefire FIREscape runs on unique addressable technology that allows you to programme, control and test each individual sign in the system.

A graphic interface lets you view the entire system at a glance. If there's a sign that's out of order, you can identify and fix it immediately.

An internal control system has been included with the system to constantly control the condition of the lights, LEDs and batteries.

If necessary, the system will provide specific information on the status, either locally on a keypad or by transferring it to the control centre of the service provider using an IP or GSM network.

In this system, FIREscape-SL (Step-Luminaire) is an LED-based addressable step lighting unit ideal for lighting up stairwells and to indicate changes in floor levels.

View Complete Details

Fire Escape Gear

  • Material Mild steel epoxy powder coated to protect against weathering
  • Warranty 3 Years
  • Mild Steel Box Size 425mm × 360mm × 140mm
  • Tested Tested to Europen Standard EN 403
  • Fire Blanket Size 1.2m × 1.8m
  • Contents One Pair Fire Blanket and Smoke Hood

While attempting to escape from a fire, there are two things you need protection from. The first is smoke. Toxic and poisonous, smoke inhalation is your first and most critical concern. The second is the fire itself. In order to survive, you must be able to navigate through the fire without sustaining serious burn injuries.

Ceasefires Escape Gear is designed to protect you against these very forces. Each Escape Gear Pack contains two Fire Escape Masks and two Fire Escape Blankets. Together they provide the protection to escape safely from the smoke and fire.

Ceasefire Fire Escape Gear, Mild Steel Box size 425mm 360mm 140mm, Epoxy powder coated to protect it from weathering.

Smoke Hood: Tested to European Standard EN 403: 1993-S, Known to reduce Carbon monoxide, propenl (acrolein), hydrogen chloride, hydrogen cyanide and solid & liquid toxic particles to manageable level for at least 15 minutes, shall withstand temperatures upto 80 Deg, Single Use only.

Fire Blanket Size: 1.2m 1.8m, Used to cover any vessel containing the fire completely, Used to extinguish a clothing fire wrap blanket around victim.

View Complete Details

Marking Strips

The range contained in Ceasefire SEE is comprehensive, covering every possible evacuation need.

For instance, marking strips are critical in areas that need special navigation in the dark, such as around pillars, corners, low-lying or protruding objects, heavy machines etc.

These floor-mounted strips glow brightly, to guide occupants on a safe, obstruction free path to the nearest exit.

View Complete Details

METALSTAR FIRE SUIT

  • Fabric Aluminized glass fiber cloth
  • Thread KEVLAR
  • Boots Oil and heat resistant sole
  • Gloves Insulated
  • Industrial Radiant Heat 1500°C
View Complete Details

ARCSTAR FIRE SUIT

  • Material Nomex Comfort 2 layers
  • Fabric Nomex
  • Jacket And Trousers Nomex made electric arc protected

Electric arcs are caused due to breakdowns of a gas, which produces a continuous discharge of plasma. This happens because current is flowing through a medium such as air, which is normally non-conductive.

The arcs are formed in the space between two conductive electrodes which are often made from carbon, and once initiated, will draw current from a fixed-voltage supply until the apparatus is destroyed. Electrical arcs are at temperatures high enough to obliterate most materials.

In the electrical industry the threat of an electric arc flash exposure has necessitated the use of flame resistant clothing. The flame resistant clothing intends to minimize burn injury and provide the worker with some protection after being exposed to an electric arc. Non-flame resistant clothing ignites and dramatically increases the burn injury percentage and severity well beyond that of the initial arc flash exposure.

Ceasefire Arcstar provides permanent flame resistance as it does not melt, ignite or continue to burn.

It uses comfortable fabrics for protection and resists breaking open during exposure.

The suit insulates the wearer from heat & decreases/avoids heat burns, providing protection to escape safely.

View Complete Details

TWIN FLUID SWIFT

  • Type of system Offered Cylinder Based or Pump Based,
  • Cylinder size 50/100 liters with working pressure of 15 Bar,
  • Extinguisher and propelling agent media Water and Nitrogen,
  • Pump size subjected to design requirement,
  • Cylinder construction material Stainless Steel,
  • Mist micron size 50 to 80 microns,
  • Pipe & Fitting construction material SS 304/316,
  • Types of nozzles CHPS,
  • Water requirement Fine filter water,
  • Design concept Approval NFPA 750,
  • Controls Automatic.
View Complete Details

Conventional Panel

  • Operating Temperature –5°C to +50°C,
  • Supply Voltage 230V AC (+10% / –15%),
  • Weight 5.5Kg,
  • Enclosure 1.2mm Steel,
  • Operating Humidity Cable Entries (20 Mm Knockouts)
  • Power Supply DC Rating 24V 3A,
  • Battery Capacity 7Ah 12V (2 per panel),
  • Number Of Fire Zones 2,
  • Sounder Outputs 2 × 0.5A (max 1.6A over all outputs),
  • Contact Rating (FAULT / Local Fire / Fire) 30V DC 1A,
  • Detection Zone Current 1.6mA,
  • Detection Zone End Of Line Resistor 6.8k ohm 5%,
  • Sounder Output End Of Line Resistor 10k ohm 5%,
  • Dimensions (MM) 385(W) × 310(H) × 92(D)

Ceasefire Conventional Fire Alarm system operates over a wide voltage range, enabling connection to Fire and Security systems, and thus minimising the variety of detectors required to fulfil the most demanding applications.

The extensive range provides flexible solutions and features application-specific products that support specialised areas of detection such as Intrinsically Safe (I.S.) and Marine applications.

Approved to European standards (EN54), this environment friendly system promises rapid and reliable installation.

View Complete Details

Conventional Call Point

  • Nominal Operating Resistance 470 ohms,
  • Ingress Protection Rating IP24,
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +70°C,
  • Maximum Humidity 95% RH - Non Condensing (at 40°C),
  • Colour /Case Material Red / ABS,
  • Weight (g) (Flush Mount) 110 (Surface Mount with Back Box) 161
View Complete Details

IR Flame Detector

  • Operating Voltage 14 – 30Vd.c.,
  • Alarm Current (Selected Via By Dil Switched) 3 – 28mA,
  • Test Signal Voltage 14 – 30Vd.c.,
  • Relay Contact Ratings Current 1.0A (max) Voltage 50Vd.c. (max) Power 
  • Field Of View 90° min. Cone,
  • Operating Wavelength Band IR (0.75 – 2.7mm),
  • Operating Temperature Range –10°C to +55°C,
  • Storage Temperature Range –20°C to +65°C,
  • Power Up Time 2 Seconds (max),
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Ingress Protection Rating Ip65,
  • Colour / Case Material Blue / Die-Cast Zinc Alloy (Za12),
  • Weight (Kg) 2
View Complete Details

Loop Driver Card

  • Support Each card supports one loop,
  • Current Drawn 500 mA rated,
  • Short Circuit isolator Built-in short circuit isolators,
  • Devices 127 ESP devices

Loop Driver Card

View Complete Details

Network Driver Card

  • Supply Voltage 24 VDC Nominal,
  • Quiescent Current Consumption 20µA,
  • Protocol RS-485,
  • Address Setting Dipswitch,
  • Operating Temperature 32F~120F,
  • Operating Humidity 90% RH
View Complete Details

Short Circuit Isolator

  • Operating Voltage 17 - 41 VDC,
  • Quiescent Current 50 µA,
  • Current In Short Circuit Maximum Short Circuit Current
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +60°C,
  • Maximum Humidity 95%RH - Non Condensing (at 40°C),
  • Colour / Case Material Red / ABS,
  • Maximum Number Of Isolators Per Loop 127,
  • Weight (g) 85,
  • Diameter (mm) / Height (mm) 100 / 13,
  • Fixing Centers (mm) 48 ~ 74,
View Complete Details

Single Zone Monitor

  • Operating Voltage 17 - 41 VDC,
  • Low Power Mode (typ) 150µ A*,
  • Quiescent Current 250µ A*,
  • Current Consumption 22µA ±20% (polling),
  • Current In Short-Circuit 8mA (SCImodule only),
  • Maximum Short-Circuit Current 1A (SCI module only),
  • Zone Voltage 15.3V - 17.1V,
  • Zone Resistance 50 ohm Max,
  • Zone Capacitance 0.3 F Max,
  • Operating Temperature Range –10° to +50°C,
  • Storage Temperature Range –30° to +60°C,
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Weight (g) 325,
  • Colour & Enclosure Material White ABS / Green ABS (DINs)
View Complete Details

Relay Controller

  • Operating Voltage 17 - 41 VDC,
  • Low Power Mode (typ) 110µ A*,
  • Quiescent Current 300µ A*,
  • Current Consumption 22µA ±20% (polling),
  • Current Consumption (Ext) 800µ A (quiescent)70µA (alarm),
  • Current In Short Circuit 8mA (SCImodule only),
  • Maximum Short- Circuit Current 1A (SCI module only),
  • Relay Contact Rating 48Vdc max, 2A (resistive load),
  • Input EOL Resistor 10, ±5% 0.25W,
  • Input Threshold Levels ON = 470 ohm, short cct Operating Temperature Range
  • Storage Temperature Range –30° to +60°C,
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Weight (g) 325,
  • Colour & Enclosure Material White ABS / Green ABS (DINs)
View Complete Details

Powered Output Module

  •    
  • Operating Voltage 17 - 31 VDC,
  • Quiescent Current 200µ A (at 41V),
  • Alarm Current 2.3 - 32.3mA,
  • Test Signal Voltage 14 to 30Vd.c,
  • Input Ratings Open Circuit > 100K ohmNormal State - 10 ohm 
  • Short Circuit Operating Temperature Range –10° to +50°C,
  • Storage Temperature Range –30° to +60°C,
  • Colour & Enclosure Material Ivory / ACS,
  • Weight (g) 30
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Uma Maheshwari (Hdfc Standard Life Insurance)
  • Sadhasivam Nagar, Madipakkam, Chennai, Tamil Nadu - 600091, India
  • Share us via
List of Other Products by Hdfc Standard Life Insurance from Chennai, Tamil Nadu.
Post Buy Requirement
HS
Chennai, Tamil Nadu, India
Add Review

Our Product / Services

  1. Sensors 3 Products available
  2. Security Alarms & Devices 4 Products available
  3. Electronic Detectors 6 Products available
  4. Fire Extinguisher 13 Products available
  5. CCTV Camera 6 Products available
  6. Photography Equipment & Supplies 3 Products available
  7. Control Panels 3 Products available
  8. Signs 3 Products available
  9. Fire Fighting & Protection 4 Products available
  10. Others 57 Products / Services available

Other Products / Services #330548

Attendance Access Control Systems

  • Operating Temperature -20°C ~ 50°C,
  • Authentication Modes Finger/ Card,
  • Fingerprint Sensor, 500 dpi optical sensor,
  • Face Detection Camera N/A,
  • Card Options 125KHz EM 13.56MHz Mifare/DesFire,
  • Template Capacity 10, 000 (1
  • Max. User 50, 000
  • Log Capacity, 50, 000
  • TCP/IP Yes (optional) Rs 485
  • Wiegand, configurable upto 64 bits,
  • Ttl I/O 2 Input,
  • Built-In Relay 1,
  • CPU 400 MHz DSP,
  • Memory 4 GB flash + 8 MB RAM,
  • Led Indicator Multi-color,
  • Sound Indication Multi-tone buzzer,
  • Tamper Switch,
  • Operating Voltage 12V DC,
  • Dimensions (W X H X D, MM) 50 x 160 x 37
View Complete Details

CO2 VALVE Type Extinguisher

We've seen how, in just a matter of seconds, a small fire can grow into a lethal blaze. If you've missed that time window, there's still hope.

Ceasefire's CO2 valve type extinguishers are bigger, pack in tremendous power and are very effective in putting out larger fires.Ceasefire's CO2 valve type extinguishers are available in three variants, with more storage capacity than the regular CO2 extinguisher.

Extremely user friendly, with a protective cover over the valve to avoid the risk of freeze burn, Ceasefire's CO2 valve type extinguishers are the perfect weapon against large, hard to fight B and C Class fires.

View Complete Details

Hammer Drill

Ceasefire brings to you Ceasefire Lancepro. Ceasefire Lancepro is arevolutionary fire fighting system that comes to address some of the biggest challenges faced by anyone fighting a blaze in a building complex.Lancepro can also be used directly in case of open fire, whilst maintain a safe distance from the blaze and protecting the goods from collateral damage.

The innovative Ceasefire Lancepro uses Watermist technology enabling it to be used safely on all types of fires including electrical
fires. Water in mist form also increases the surface area of water many times over facilitating heat absorption and taking the firefighting
power manifold by rapidly bringing down the temperature to below combustible levels and cutting off the oxygen supply.

Having a drill machine along in the Lancepro kit makes it convenient for the fire fighter to douse off the fire in an enclosed area without physically coming in contact with it. A small orifice is all you need to ensure the security of the fire fighter who can quench the fire without actually entering the enclosed space. The drill comes with two bits one for drilling in concrete surface and another for metal surface drilling. Once the opening is made by the drill unit of Lancepro the watermist gun is inserted through the opening and watermist is discharged.The two types of guns specialize in administering watermist into the fire zone from a horizontal (from the wall) and vertical
(from the roof) angle, respectively.

View Complete Details

Basic Security Kit

Contrary to popular belief, most burglaries are not random, unplanned acts. In most cases, the burglar is someone who has observed you over time: a former household help or even your ex-watchman could be a potential threat.

He knows your property, the people in it and in many cases, their routine. As for your valuables, every experienced burglar knows where to find them: drawers, cupboards and safes.

So how can you protect yourself against even the most calculated attack?

With Ceasefires security system you can leave your home confident that a break-in will automatically sound an alarm, activate a response, and inform you via your telephone.

Motion detectors, wired siren, magnetic contacts and curtain detectors alert you the second an intruder breaks in. Flood and smoke detectors alert you in case of flooding and fire. And the central control panel monitors the overall security of your home. This system leaves no corner unguarded.

View Complete Details

Basic Panel

  • Dimension: (250 x 190 x 44 mm).
  • Humidity: 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range: -4°F to 140°F (-20°C to 60°C)
  • Weight: 1050 gms

Contrary to popular belief, most burglaries are not random, unplanned acts. In most cases, the burglar is someone who has observed you over time: a former household help or even your ex-watchman could be a potential threat.

He knows your property, the people in it and in many cases, their routine. As for your valuables, every experienced burglar knows where to find them: drawers, cupboards and safes.

So how can you protect yourself against even the most calculated attack?

With Ceasefires security system you can leave your home confident that a break-in will automatically sound an alarm, activate a response, and inform you via your telephone.

Motion detectors, wired siren, magnetic contacts and curtain detectors alert you the second an intruder breaks in. Flood and smoke detectors alert you in case of flooding and fire. And the central control panel monitors the overall security of your home. This system leaves no corner unguarded.

Number of Zones:29 wireless, 1 hardwired (zone No. 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior, perimeter, delay 1, delay 2, 24 hours - audible, 24 hours - silent, fire, non-alarm and emergency.
User Codes:8 codes, 4 digits each
Data Retrieval:Status, alarm memory, trouble, event log.
Real Time Clock: The control panel keeps and displays time and date.
Compliance with U.S Standards:Meets FCC Part 15 and Part 68 requirements.
Compliance with European Standards:EN 50131-1 Grade II Class II
EMC Emission:EN 50081-1 1992
RFI:EN55022 1998
EMC Immunity:EN 50082-1 1997
EMC Immunity to Conducted RF:EN6100-4-6 1996
Telephony:Telephony: TBR21 1998
Safety:EN60950+ Am1(93), Am2(93), Am3(95), Am4(97)
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Coding:PowerCode and/or CodeSecure
Power Supply :Plug-in transformer.230 VAC, 50 Hz / 9 VAC, 700 mA or 230 VAC, 50 Hz /9 VAC, 1A.
Current Drain:Approx. 95 mA standby, 500 mA at full load and in alarm.
PGM (auxiliary)
Output Current:100 mA max.
Sounder Output Current with 700 mA Transformer :Internal sounder: 50 mA maxExternal sounder:150 mA max
Sounder Output Current with 1A Transformer:Internal sounder: 50 mA max / External sounder: 350 mA max.
Fuse Rating:0.5 A for siren / sounder circuit protection.
Backup Battery :(provides power for at least 4 hours) Option - 7.2 V Nickel-Metal rechargeable battery pack, 1300 mAh.
Built-in Modem:300 baud, Bell 103 protocol
Data Transfer to Local Computer:Via RS232 serial port
Report Destinations: 2 central stations, 4 private telephones
Reporting Format Options:SIA, Pulse 4/21900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Pulse Rate: 10, 20, 33 and 40 pps programmable
Message to Private Phones:Tone or voice
Message to Pager:PIN No. * Alarm Type * Zone No.
Operating Temp. Range:32F to 120F (0C to 49C)

View Complete Details

Magnetic Contact Switch

  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Dimensions 81 x 23.5x32.5 mm
  • Weight 34 gms
  • Magnet 13 gms
  • Resistor Required 47 kΩ,
  • Power Source 3.6 V Lithium battery

Transmitter's ID Code:24-bit digital word, over 16 million combinations, pulse width modulation.
Overall Message Length:36 bits
Alarm Inputs:Alarm Inputs: 2, one internal and one external, with a separate 24-bit transmitter ID each.
Auxiliary Input Circuit Type:N.C. / E.O.L., selected with DIP switch, E.O.L.

View Complete Details

One Way Key Fob

  • Dimensions 53.5 X 31.5 X 12.5 MM
  • Weight (including battery) 21 gms
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Battery Life Expectancy 1 year (for typical use)
  • Modulation Ask (ON-OFF keying)
  • Power Supply 12 V alkaline battery


Battery Supervision

Good battery - LED lights steadily upon transmission /Low attery - LED flickers upon transmission

Coding

28-bit ID, 4-bit function code and 32-bit rolling code


Transmission Duration

Each button press causes transmission for upto 2 seconds

View Complete Details

Oval Pet Motion Detector

  • Detector Type Dual element low noise pyroelectric sensor.
  • No. of Curtain Beams 9
  • Max. Coverage 12 x 12 m (40 x 40 ft) / 90°
  • Pet Immunity Up to 38 kg (85 lb).
  • Standby Current Drain Approx. 0.025 mA.
  • Nominal Battery Capacity 1450 mA/h.
  • Weight 70 gms.

Internal Battery:3V Lithium battery, type CR-123A. For UL installations, use Panasonic or Sanyo only.

Transmit Current Drain:20 mA (including LED).


Battery Life (with LED on):Typically over 3 years.


True Motion Event Verification:2 position selector - 1 (OFF) or 2 (ON) motion events.


Alarm Period:3 seconds.


Rearm Timer:Rearms the detector 2 minutes after the last alarm.
Timer disabled in the walk test mode not applicable for the DD243 version (see section 1).


Transmission Sequence:3 data bursts at variable intervals within 3 seconds.


Encoding:24-bit ID, over 16 million possible combinations. Total.


Message Length:36 bits.


Tamper Alert:Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored.


Supervision Message: Signaling at 60 minutes interval (U.S. version)
15 minute interval (UK version) or according to local standards.


Height:1.8 - 2.4 m (6 - 8 ft). Recommended height up to 2.1 m (7 ft)
Installation Options:Surface or corner


BR-1:Surface mounted swivel bracket, adjustable 30 down and 45 left/45 right, BR-1 with a corner adapter, BR-1 with a ceiling adapter


RFI Protection:>20 V/m up to 1000 MHz.


Operating Temperatures:-10C to 50C (14F to 122F).


Storage Temperatures:-20C to 60C (-4F to 140F).


Compliance with Standards:Designed to meet FCC Part 15 and Directive 1999/5/EC of the European Parliament.


Dimensions (H x W x D):94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16).

View Complete Details

Rectangular Pet Motion Detector

  • Weight 92 gms without bracket, 107 gms with bracket.
  • Dimensions (H x W x D) 117 x 65 x 47 mm.
  • Storage Temperatures 20°C to 60°C (-4°F to 140°F).
  • Operating Temperatures -10°C to 50°C (14°F to 122°F).
  • RFI Protection >30 V/m up to 1000 MHz.
  • Height Up to 2.4 m (8 ft)

Max. Coverage Range

12 x 12 m (40 x 40 ft) / 90.


Pet Immunity

Animals up to 36 kg - not verified by UL.


Vertical Adjustment

3-position adjustment scale: 1.8 m (6 ft), 2.1m (7 ft) and 2.4 m (8 ft).


Internal Battery

3V Lithium battery


Nominal Battery Capacity

750 mAh


Standby Current Drain

0.015 mA


Transmit Current Drain

20mA (including LED)


True Motion Event Verification

2 position selector - 1 (OFF) or 2 (ON) motion events.


Alarm Period

3 seconds


Transmission Sequence

3 data bursts at variable intervals within 3 seconds.


Encoding

24-bit ID, over 16 million possible combinations.


Total Message Length

36 bits.


Height

Up to 2.4 m (8 ft)


Bracket Adjustment

20 downward (only in non-pet immune applications), 20 left and right

View Complete Details

Curtain Detector

  • Dimensions (H x W x D) 105 x 35 x 30 mm
  • Weight 60 gms
  • Storage Temperature -20°C to 60°C (-4°F to 140°F).
  • Operating Temperature -10°C to 50°C (14°F to 122°F).
  • Mounting Height 1.8 - 2.4 m (6 - 8 ft).
  • Total Message Length 36 bits.

Detector Type

Dual-element low noise pyroelectric sensor.

Range Settings

Long (6 m), Medium (4 m) and Short (2 m).


Internal Battery

3V Lithium battery


Nominal Battery Capacity

1450 mA/h.


Microprocessor

8-bit, low power CMOS.


Alarm Period

Approx. 3 seconds.


Rearm Timer

Rearms the detector 2 minutes after the last alarm.


Transmission Sequence

3 data bursts at variable intervals within 3 Seconds.


Encoding

24-bit ID, over 16 million possible combinations.

View Complete Details

Repeaters

  • Dimensions (H x W x D) 110 x 63 x 25
  • Weight 73 gms
  • Operating Temperature 0 °C to 49°C (32° F to 120° F).
  • LED indicator Lights during transmission.
  • Modulation Type 100% ASK.
  • Power Input Ranges 13 - 20 VDC, or 11 - 16 VAC, 100 mA min.

Compliance with Standards

Meets FCC Part 15, MPT 1340 and directive 1999/5/EC

Backup Battery

9 V-style rechargeable Ni-Cd or Ni-MH. Battery Backup Duration (with fully charged 120 mA/h battery and 1:1 standby/transmit ratio): 2 hours (315 and 433.92 MHz units)

View Complete Details

Flood Detector

  • Weight (including battery) 45gms
  • Dimensions 81 x 23.5x32.5 mm
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Weight of Flood Sensor Cable Approx 60 gms
  • Length of Flood Sensor Cable 3 meters
  • Nominal Battery Capacity 750 mAh

Transmitter's ID Code

24 bit digital word, over 16 million combinations, pulse width modulation.


Overall Message Length

36 bits
Message Repetition

One-shot transmission (default) or once every 3 minutes (selectable)


Power Source

3V Lithium battery


Current Drain

6A STBY, 17mA average in operation (including LED

View Complete Details

Wireless Pendant

  • Color White.
  • Power Supply 12-volt alkaline battery
  • Dimensions 32 x 57 x 16 mm
  • Weight 22 Gms
  • Operating Temperature 0° to 49°C (32° to 120°F).

Encoding

24-bit digital word, over 16 million combinations.


Transmission duration

As long as the button is kept pressed.

View Complete Details

Wrist Transmitter

  • Color: Black (Purple button)
  • Weight: 25 Gms
  • Dimensions: 35 mm (1.4 in.).
  • Operating Temperature: 0° to 50°C (32° to 122°F).
  • Nominal Battery Capacity: 150 mAh
  • Power Supply: 3-volt Lithium cell

Modulation

ASK (ON-OFF keying)


Transmitter ID

24-bit digital word, over 16 million possible code combinations, pulse width modulation.


Total Message Length 36 bits

Minimum Transmit Duration2 sec
Power Supply:3-volt Lithium cell

View Complete Details

Glass Break Detector

  • Weight 130 gms
  • Dimensions 80 x 108 x 43 mm
  • Operating Temperature 0°C to 49°C (32°F to 120°F).
  • Tempered 3.2 to 6.4 mm (1/8 to 1/4")
  • Plate 2.4 to 6.4 mm (3/32 to 1/4")
  • Wired 6.4 mm (1/4")

Microphone:Omni-directional electret
Alarm Duration:4 seconds
RF immunity: 20 V/m, 1 MHz to 1000 MHz
Temperature range: -10 to 50C (14 to 120F)
Minimum:0.3 x 0.6 m (1 x 2') or larger glass thickness
Plate:2.4 to 6.4 mm (3/32 to 1/4")
Tempered:3.2 to 6.4 mm (1/8 to 1/4")
Wired:6.4 mm (1/4")
Laminated:3.2 to 6.4 mm (1/8" to 1/4")
Transmitter's ID Code:24-bit digital word, over 16 million combinations, pulse width modulation.
Overall Message Length:36 bits
Response to Tamper Event:Tamper report every 3 minutes (until the tamper switch is restored).

View Complete Details

Wireless Pro Panel System

  • Weight 1600 g ms
  • Dimension 285 x 215 x 55 mm
  • Humidity 85% relative humidity, @ 30°C (86°F)
  • Storage Temp. Range -4°F to 140°F (-20°C to 60°C)
  • Operating Temp. Range 14°F to 120°F (-10°C to 49°C)
  • Message to Private Phones Tone or voice

Zones Number:28 wireless, 2 hardwired (zones 29 & 30).
Hardwired Zone Requirements:2.2 k E.O.L. resistance (max. resistance of wires 220 ).
Zone Types:Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
Display:Single line, Backlit 16-character LCD.
Alarm Types:Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
Siren Signals:Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse. (fire).
Siren (bell) Timeout:Programmable
InternalSounder Output:At least 85 dBA at 10 ft (3 m)
Supervision:Programmable time frame for inactivity alert
Data Retrieval:Status, alarm memory, trouble, event log.
Compliance with U.S. Standards:Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC C1023.
Receiver Type:Super-heterodyne, fixed frequency
Receiver Range:600 ft (180 m) in open space
Antenna Type:Spatial diversity
Coding:PowerCode and/or CodeSecure
Power Supply:Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
Maximum Output Ripple:0.05
Current Drain: Approx. 40 mA standby, 1400 mA at full load and in alarm.
Site External Siren Current (EXT):450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
Site Internal Siren Current (INT):450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
PGM Output Current:100* mA max.
Wired Detectors (zones 29 & 30)
Total (Sum) Current: 36* mA max.
High Current / Short Circuit Protection: All outputs are protected (automatic reset fuse).
Total Pro Panel output current: 550 mA.

View Complete Details

Wireless Camera

  • Resolution 320 * 240 image resolution
  • Certification CE and FCC
  • Lens Type Board Lens
  • Focus Lens 20 cm from infinity.
  • Image sensor CMOS (complementary metal oxide semiconductor)
  • Power Powered by AC wall outlet
View Complete Details

Remote Commander

  • Battery 3 VDC, Lithium battery.
  • Weight 130Gms
  • Current Consumption 10 μA approx. (STBY),
  • Back light illumination Selectable on/off.
  • Dimensions (HxWxD) 127 x 72 x 24 mm
  • Operating Temperatures 0° to 49°C (32° to 120°F)

95mA (in transmission, including LED and back light currents).

View Complete Details

KEYPAD Control System

  • Nominal Voltage 12 VDC
  • Display LDC graphical display 128 × 64 pixels
  • Display Viewing Area (mm) 60.0 × 32.5
  • Case Colour Light grey
  • Dimensions (mm) 147W × 144H × 29D
View Complete Details

DIN Rail Switch

  • Supply Voltage 230V +10% -15% 50 Hz
  • Supply Current ≤ 20 mA capacitive
  • Making Capacity - 2000 W ( incandescent lamp) - 3 A (motors) - 16 A (resistive loads)
  • EMC Emission A ccording to EN 50081-1
  • EMC Immunity A ccording to EN 50082-1
  • Electrical Safety A ccording to EN 60950 1 and EN 60065
  • Signal Sensitivity 5 mVpp min 50 mVp max at 120 kHz
  • Input Impedance ≥ 180 Ohms (L - N) at 120 kHz
  • Connections S crew type terminals for phase, eutral, switched phase,  
  • Dimensions 81 x 23.5x32.5 mm
  • Ambient Temperature 10° C to + 40° C (operation) - 20° C to + 70° C 
View Complete Details

Night Box Camera

  • Sensor 1/3" SONY Vertical Double Density Interline CCD
  • Total Pixels NTSC=811(H) * 508/(V) / PAL=795(H) * 595(V)
  • Effective Pixels NTSC=768(H) * 494(V) / PAL=752(H) * 582(V)
  • Scanning System 2
  • Synchronization Internal
  • O.S.D Built-in
  • Dynamic Range 52dB
  • Backlight WDR / BLC / OFF Selectable
  • Resolution 560TV Lines
  • S/N (Y signal) 52dB
  • Minimum Illumination 0.001Lux (Sens-Up * 128X)
  • White Balance ATW / AWC / Manual / Outdoor / Indoor
  • Electronic Shutter Speed AUTO(NTSC=1/50sec ~ 1/100, 000sec 
  • Sense-Up AUTO (Selectable limit x2 ~ x256) / OFF
  • Gain Control HIGH / LOW / OFF Selectable
  • DNR OFF/ON (1~32 Level Adjustable)
  • Motion Detection ON/OFF (8 Zone, ALARM Output)
  • Privacy ON/OFF (8 Programmable Zones)
  • Mirror(H-REV) ON/OFF
  • FLIP(V-REV) ON/OFF
  • Sharpness ON/OFF (Level Adjustable)
  • D&N Selection COLOR / BLACK & WHITE / AUTO / EXTERNAL
  • DIS ON/OFF
  • Digital Zoom ON (0 ~ 230 Level Adjustable) / OFF
  • Communication RS-485 (Pelco-D Protocol)
  • Power DC 12V
  • Power Consumption 120mA
  • Lens C&CS Mount(Lens Option)
  • Operating Temperature/Humidity -10°C to +50°C. RH 95% Max.
  • Storage Temperature/Humidity -20°C to +60°C. RH 95% Max.
  • Dimension 58mm(W) * 52mm(H) * 123mm(D)
  • Weight 350g
View Complete Details

Digital Video Recorders

  • Weight 2500 gms
  • Sensor/Relay/PTZ interface Sensor input(4Ch), Relay output(1Ch)
  • HDD Capacity 1 SATA HDD Back up
  • Network xDSL, Cable Modem, LAN(Ethernet 10/100 base-T)
  • Power Supply DC 12V/5A
  • Power Consumption 25W
  • Operating Temperature 5°C to 40°C
  • Dimensions 250(W) X 65(H) X 155(D)mm

Video Mode: NTSC/PAL

O/S: Embedded Linux

Compression:Standard H.264 / ADPCM(Audio)

Video Input: 4Ch

Video Output:Monitor(1 BNC, 1 VGA)

[Speed] Live Display (NTSC/PAL):120fps/100fps

[Speed] Recording (NTSC/PAL):120fps/100fps

Recording Resolution (NTSC/PAL):Full (720 X 480)/Full (720 X 576), Field (720 X 240)/Field (720 X 288), CIF (352 X 240)/CIF (352 X 288)

Live Display:1/4/Sequence

Recording mode:Auto, Continuous, Motion, SensorAudio:Input (1Ch), Output (1Ch)

View Complete Details

Motion Sensor Lights

  • Operating Voltage ~220-240V / 50 Hz
  • Lighting Load 2x25W
  • E27 Akkor Lamp Detection Angle 360°Detection Height
  • Detection Range 8 m.
  • Dia Time Adjustment 10 sec ~5min
  • Daylight Adjustment Yes
  • Operating Temperature -20°C to +40°C
  • Protection Class IP20
  • Standard Compliance TS EN 60669-2-1 ve TS EN 60598-2-1
View Complete Details

Led Sensor Light

  • Operating Voltage ~220-240V / 50 Hz,
  • Lighting Load 2x25W E27 Lamp,
  • Detection Angle 360°,
  • Detection Height 2.8 m.,
  • Detection Range 9 m. Diameter
  • Time Adjustment 10 sec ~5min,
  • Daylight Adjustment Available,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP20,
  • CE & Rohs Compatible Yes
View Complete Details

Emergency Light

  • OPERATING VOLTAGE ~220-240V / 50 Hz
  • LIGHTING LOAD 2x25W E27 Lamp
  • DETECTION ANGLE 360°
  • DETECTION HEIGHT 2.8 m.
  • DETECTION RANGE 9 m. Dia
  • TIME ADJUSTMENT 10 sec ~5min
  • BATTERY TYPE 1x9V 200mAh NiMh Square Battery
  • BATTERY CHARGE TIME 5 hour one battery 10 hour double battery
  • BATTERY DICHARGE TIME 1-7 hour one battery 2-14 hour double battery
  • DAYLIGHT ADJUSTMENT Yes
  • OPERATING TEMPERATURE -20°C to +40°C
  • PROTECTION CLASS IP20
  • STANDARD COMPLIANCE TS EN 60669-2-1 ve TS EN 60598-2-1
  • ROHS Compatible
View Complete Details

Wall Mounted Light

  • Operating Voltage ~220-240V / 50 Hz,
  • Lighting Load 1x60W,
  • Detection Angle 180°,
  • Detection Height 2.8 m.,
  • Detection Range 3m. - 12m.,
  • Time Adjustment 10 sec ~5min,
  • Sensitivity Adjustment Yes,
  • Daylight Adjustment 5-1000 LUX,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP44,
  • CE Yes,
  • Standard Compliance TS EN 60669-2-1 ve TS EN 60598-2-1,
  • Dimensions (mm) 220x280x95 mm,
  • Box Weight 16.5 kg, Box Dimensions
  • Piece Per Package 8 Pcs,
  • Rohs Compatible
View Complete Details

Door Guard

  • Certification CE
  • Holding Force 280 Kg and 500 Kg (both are available),
  • Current Drawn 480 mA at 12 VDC and 240 mA and 24 VDC ,
  • Weight 2 Kg ,
Any intruder trying to break through a door guarded by an EM Lock will find themselves pitted against a holding force of 600lbs. This magnetic lock works on a current of 480mA at 12VDC and is impossible to open by force.

View Complete Details

Boundary Guard Post

  • Coverage 24m (12m on each side),
  • Power Supply 3 - 9VDC lithium or alkaline battery,
  • Operating Temperature –20°C - + 50°C,
  • Weight 520 g,
  • Detection Zones 4 Zones (2 zones on each side),
  • Sensitivity 2.0°C at 0.6m/sec,
  • Detectable Speed 0.3m – 1.5m/s,
  • Current Consumption 3mA(Walktest, LED on) 15uA(Standby),
  • Alarm Period 2 ± 1 sec,
  • Alarm Output Form C-Solid state switch
  • Battery Saving Time Approx. 120 sec. or 5 sec.,
  • Tamper Switch Form C opens when cover is removed,
  • Warm-Up Period Approx. 2 min.,
  • Led Indicator Disable during normal operation & Enable during walk test or LED switch on,
  • Environmental Humidity 95% max.,
  • Rf Interference No Alarm 20V/m,
  • Mounting Height 0.8m – 1.2m,
  • Mounting Wall,
  • Weatherproof IP55
View Complete Details

Gas Leak Detector

  • Operating Voltage 9V DC,
  • Response Time 30s,
  • Gas Sampling Natural diffusion,
  • Alarming Method Visual and audiable,
  • Alarm Sound 85dB,
  • Sensor Life Approx. 5 Years,
  • Weight about 420 g,
  • Dimensions (L × W × H) 170 × 100 × 45 mm,

Alarming Level :50 ppm between 60 to 90 mins 100 ppm between 10 to 40 mins 300 ppm less than 3 mins,

View Complete Details

Staircase Light Timer

  • Operating Voltage 230-240VAC /50Hz,
  • Lighting Load 2200W for E27/800W for Flo.,
  • Time adjustment 6sec-6min.,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Video Distributor

  • Video Distribution From the junction Points,
  • Operating Voltage From Central Unit,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Guard Telephone Handset

  • LCD Digital LCD screen,
  • Operating Voltage From Central Unit,
  • Name List Yes,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Multi System Video Power Supply

  • Relay Outputs 3 door lock relay output,
  • Power Supply Switch Mode power supply,
  • Operating Voltage 85-265 VAC (50-60 Hz),
  • Output Voltage 24V DC,
  • Current 3.5A,
  • Operating Temperature –20° to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Apartment Door Camera

  • Camera Color,
  • Operating Voltage From Central,
  • Operating Temperature -20°C to +40°C,
  • Protection Class IP20,
  • Certified CE
View Complete Details

Downlights

  • Case Color Ivory
  • Operation Time 1h to 3h
  • Material Fire resistant ABS plastic
  • Dimensions (mm) 99.7 * 50H
View Complete Details

STEP LUMINAIRE

  • Material Fire resistant PC +ABS plastic (FR3010)
  • Fire class UL94V-O
  • Operation TIME 1h / 3h
  • Dimensions (MM) 80Wx80Hx12D

Ceasefire FIREscape runs on unique addressable technology that allows you to programme, control and test each individual sign in the system.

A graphic interface lets you view the entire system at a glance. If there's a sign that's out of order, you can identify and fix it immediately.

An internal control system has been included with the system to constantly control the condition of the lights, LEDs and batteries.

If necessary, the system will provide specific information on the status, either locally on a keypad or by transferring it to the control centre of the service provider using an IP or GSM network.

In this system, FIREscape-SL (Step-Luminaire) is an LED-based addressable step lighting unit ideal for lighting up stairwells and to indicate changes in floor levels.

View Complete Details

Fire Escape Gear

  • Material Mild steel epoxy powder coated to protect against weathering
  • Warranty 3 Years
  • Mild Steel Box Size 425mm × 360mm × 140mm
  • Tested Tested to Europen Standard EN 403
  • Fire Blanket Size 1.2m × 1.8m
  • Contents One Pair Fire Blanket and Smoke Hood

While attempting to escape from a fire, there are two things you need protection from. The first is smoke. Toxic and poisonous, smoke inhalation is your first and most critical concern. The second is the fire itself. In order to survive, you must be able to navigate through the fire without sustaining serious burn injuries.

Ceasefires Escape Gear is designed to protect you against these very forces. Each Escape Gear Pack contains two Fire Escape Masks and two Fire Escape Blankets. Together they provide the protection to escape safely from the smoke and fire.

Ceasefire Fire Escape Gear, Mild Steel Box size 425mm 360mm 140mm, Epoxy powder coated to protect it from weathering.

Smoke Hood: Tested to European Standard EN 403: 1993-S, Known to reduce Carbon monoxide, propenl (acrolein), hydrogen chloride, hydrogen cyanide and solid & liquid toxic particles to manageable level for at least 15 minutes, shall withstand temperatures upto 80 Deg, Single Use only.

Fire Blanket Size: 1.2m 1.8m, Used to cover any vessel containing the fire completely, Used to extinguish a clothing fire wrap blanket around victim.

View Complete Details

Marking Strips

The range contained in Ceasefire SEE is comprehensive, covering every possible evacuation need.

For instance, marking strips are critical in areas that need special navigation in the dark, such as around pillars, corners, low-lying or protruding objects, heavy machines etc.

These floor-mounted strips glow brightly, to guide occupants on a safe, obstruction free path to the nearest exit.

View Complete Details

METALSTAR FIRE SUIT

  • Fabric Aluminized glass fiber cloth
  • Thread KEVLAR
  • Boots Oil and heat resistant sole
  • Gloves Insulated
  • Industrial Radiant Heat 1500°C
View Complete Details

ARCSTAR FIRE SUIT

  • Material Nomex Comfort 2 layers
  • Fabric Nomex
  • Jacket And Trousers Nomex made electric arc protected

Electric arcs are caused due to breakdowns of a gas, which produces a continuous discharge of plasma. This happens because current is flowing through a medium such as air, which is normally non-conductive.

The arcs are formed in the space between two conductive electrodes which are often made from carbon, and once initiated, will draw current from a fixed-voltage supply until the apparatus is destroyed. Electrical arcs are at temperatures high enough to obliterate most materials.

In the electrical industry the threat of an electric arc flash exposure has necessitated the use of flame resistant clothing. The flame resistant clothing intends to minimize burn injury and provide the worker with some protection after being exposed to an electric arc. Non-flame resistant clothing ignites and dramatically increases the burn injury percentage and severity well beyond that of the initial arc flash exposure.

Ceasefire Arcstar provides permanent flame resistance as it does not melt, ignite or continue to burn.

It uses comfortable fabrics for protection and resists breaking open during exposure.

The suit insulates the wearer from heat & decreases/avoids heat burns, providing protection to escape safely.

View Complete Details

TWIN FLUID SWIFT

  • Type of system Offered Cylinder Based or Pump Based,
  • Cylinder size 50/100 liters with working pressure of 15 Bar,
  • Extinguisher and propelling agent media Water and Nitrogen,
  • Pump size subjected to design requirement,
  • Cylinder construction material Stainless Steel,
  • Mist micron size 50 to 80 microns,
  • Pipe & Fitting construction material SS 304/316,
  • Types of nozzles CHPS,
  • Water requirement Fine filter water,
  • Design concept Approval NFPA 750,
  • Controls Automatic.
View Complete Details

Conventional Panel

  • Operating Temperature –5°C to +50°C,
  • Supply Voltage 230V AC (+10% / –15%),
  • Weight 5.5Kg,
  • Enclosure 1.2mm Steel,
  • Operating Humidity Cable Entries (20 Mm Knockouts)
  • Power Supply DC Rating 24V 3A,
  • Battery Capacity 7Ah 12V (2 per panel),
  • Number Of Fire Zones 2,
  • Sounder Outputs 2 × 0.5A (max 1.6A over all outputs),
  • Contact Rating (FAULT / Local Fire / Fire) 30V DC 1A,
  • Detection Zone Current 1.6mA,
  • Detection Zone End Of Line Resistor 6.8k ohm 5%,
  • Sounder Output End Of Line Resistor 10k ohm 5%,
  • Dimensions (MM) 385(W) × 310(H) × 92(D)

Ceasefire Conventional Fire Alarm system operates over a wide voltage range, enabling connection to Fire and Security systems, and thus minimising the variety of detectors required to fulfil the most demanding applications.

The extensive range provides flexible solutions and features application-specific products that support specialised areas of detection such as Intrinsically Safe (I.S.) and Marine applications.

Approved to European standards (EN54), this environment friendly system promises rapid and reliable installation.

View Complete Details

Conventional Call Point

  • Nominal Operating Resistance 470 ohms,
  • Ingress Protection Rating IP24,
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +70°C,
  • Maximum Humidity 95% RH - Non Condensing (at 40°C),
  • Colour /Case Material Red / ABS,
  • Weight (g) (Flush Mount) 110 (Surface Mount with Back Box) 161
View Complete Details

IR Flame Detector

  • Operating Voltage 14 – 30Vd.c.,
  • Alarm Current (Selected Via By Dil Switched) 3 – 28mA,
  • Test Signal Voltage 14 – 30Vd.c.,
  • Relay Contact Ratings Current 1.0A (max) Voltage 50Vd.c. (max) Power 
  • Field Of View 90° min. Cone,
  • Operating Wavelength Band IR (0.75 – 2.7mm),
  • Operating Temperature Range –10°C to +55°C,
  • Storage Temperature Range –20°C to +65°C,
  • Power Up Time 2 Seconds (max),
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Ingress Protection Rating Ip65,
  • Colour / Case Material Blue / Die-Cast Zinc Alloy (Za12),
  • Weight (Kg) 2
View Complete Details

Loop Driver Card

  • Support Each card supports one loop,
  • Current Drawn 500 mA rated,
  • Short Circuit isolator Built-in short circuit isolators,
  • Devices 127 ESP devices

Loop Driver Card

View Complete Details

Network Driver Card

  • Supply Voltage 24 VDC Nominal,
  • Quiescent Current Consumption 20µA,
  • Protocol RS-485,
  • Address Setting Dipswitch,
  • Operating Temperature 32F~120F,
  • Operating Humidity 90% RH
View Complete Details

Short Circuit Isolator

  • Operating Voltage 17 - 41 VDC,
  • Quiescent Current 50 µA,
  • Current In Short Circuit Maximum Short Circuit Current
  • Operating Temperature Range –10°C to +50°C,
  • Storage Temperature Range –30°C to +60°C,
  • Maximum Humidity 95%RH - Non Condensing (at 40°C),
  • Colour / Case Material Red / ABS,
  • Maximum Number Of Isolators Per Loop 127,
  • Weight (g) 85,
  • Diameter (mm) / Height (mm) 100 / 13,
  • Fixing Centers (mm) 48 ~ 74,
View Complete Details

Single Zone Monitor

  • Operating Voltage 17 - 41 VDC,
  • Low Power Mode (typ) 150µ A*,
  • Quiescent Current 250µ A*,
  • Current Consumption 22µA ±20% (polling),
  • Current In Short-Circuit 8mA (SCImodule only),
  • Maximum Short-Circuit Current 1A (SCI module only),
  • Zone Voltage 15.3V - 17.1V,
  • Zone Resistance 50 ohm Max,
  • Zone Capacitance 0.3 F Max,
  • Operating Temperature Range –10° to +50°C,
  • Storage Temperature Range –30° to +60°C,
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Weight (g) 325,
  • Colour & Enclosure Material White ABS / Green ABS (DINs)
View Complete Details

Relay Controller

  • Operating Voltage 17 - 41 VDC,
  • Low Power Mode (typ) 110µ A*,
  • Quiescent Current 300µ A*,
  • Current Consumption 22µA ±20% (polling),
  • Current Consumption (Ext) 800µ A (quiescent)70µA (alarm),
  • Current In Short Circuit 8mA (SCImodule only),
  • Maximum Short- Circuit Current 1A (SCI module only),
  • Relay Contact Rating 48Vdc max, 2A (resistive load),
  • Input EOL Resistor 10, ±5% 0.25W,
  • Input Threshold Levels ON = 470 ohm, short cct Operating Temperature Range
  • Storage Temperature Range –30° to +60°C,
  • Maximum Humidity 95%RH - Non- Condensing (at 40°C),
  • Weight (g) 325,
  • Colour & Enclosure Material White ABS / Green ABS (DINs)
View Complete Details

Powered Output Module

  •    
  • Operating Voltage 17 - 31 VDC,
  • Quiescent Current 200µ A (at 41V),
  • Alarm Current 2.3 - 32.3mA,
  • Test Signal Voltage 14 to 30Vd.c,
  • Input Ratings Open Circuit > 100K ohmNormal State - 10 ohm 
  • Short Circuit Operating Temperature Range –10° to +50°C,
  • Storage Temperature Range –30° to +60°C,
  • Colour & Enclosure Material Ivory / ACS,
  • Weight (g) 30
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Uma Maheshwari (Hdfc Standard Life Insurance)
  • Sadhasivam Nagar, Madipakkam, Chennai, Tamil Nadu - 600091, India
  • Share us via