Our product range contains a wide range of Radiant Warmer and Open Care System

Radiant Warmer

  • Condition New
  • Type Medical Equipment
  • Material Stainless Steel
  • Color White
  • Usage Thermoregulation For Newborn Infants
  • Packaging Box
  • Controller Type Microcomputerized System
  • Heater Type Single Element Ceramic Heater
  • Physical Parameters Length: 700mm, Width: 430mm, Thickness: 25mm, Weight: 35kg
  • Environmental Specifications Operating Temp: 20°C To 33°C, Storage Temp: -25°C To 60°C, Humidity: 0-100%RH
  • Skin Temperature Probe Range: 28°C To 38°C, Accuracy: +/-0.2°C, Resolution: 0.1°C

We offer Radiant Warmer is innovatively designed to meet thermoregulatory requirements of new born infants who suffer extremes of heat loss. The radiant warmer can be used in delivery rooms and neonatal intensive care units. The micro control based servo control radiant warmer detects minute variations in skin temperature and adjust the ceramic infrared heater output to maintain the infant's temperature at a prescribed pre set level. salient features the controller is based on microcomputerized systemlarge bnght displays are easy to monitor and for viewing from a distancedouble digital display system provided to measure the infant temperature and to set the required temperaturefeather touch keys provided for easy operationledsystem provided to indicate the heater outputmanual control system providedfault indications with alarm forbaby probe failure1 oc temperature high1 oc temperature lowhigh temperature cut-offpower failure baby probe baby probe is made of highly sensitive sensor and is interchangeable, field calibration taken care of by software the probe is made up of silicon sheathed cable, which allows easy cleaning baby trolley (optional) a detachable baby trolley which consists of large baby tray & is made of stainless steel frame with three side acrylic collapsible walls. Trendelenburg & fowler system provided observation lamp a halogen based observation light focus on any area on the bed heater smgle element (e approved ceramic heater placed in a parabolic reflector other facilities provision of oxygen cylinderi v stand providedmonitor tray provided physical parameters length : 700 mmwidth : 430 mmthickness : 25 mmworking level from ground : 900 mmbaby tray is tilt angle on either side : +/-8omaxweight approx : 35 kgcastors : 50 mm with 2 brake wheels and 2 non - brake wheels recommended environmental specifications operating temperature range : 200oc to 33ocstorage temperature range : -25oc to 600ocoperating humidity range : 0- 100%rh skin temperature probe range : 28oc to 38ocaccuracy : +/-0.2oc within rangeresolution : 0.1ocprobe interchangeability : +/-0.oc (servo)heater output controllable from 0 to 100% in manual mode (continuously variable) observation light halogen based power required : 230v, 50 w electrical specifications electrical supply : 230v ± 10%, 50hzpower consumption with heater at max. Output : 750w power consumption with heater, observation lamps on : 800w electrical safety as per iec 60601-1-2 for medical equipments note : best results obtained if air convective current is low.

View Complete Details

Open Care System

The company presents family of radiant warmers to meet the diverse thermo regulatory requirements of patient at your hospital. V-800 Open Care System is designed according to the most recent international standards and provides the neonate with an adequate and secure environment of its care. This compact and mobile Open Care System with integrated phototherapy system is a must for every well-run and busy hospital. The integrated halogen based Phototherapy system ensures that optimum therapeutic output is available on demand to manage the hyperbilirubinaemia without disturbing the infant. Features
  • The controller is based on Microcomputerized system.
  • Large bright displays are easy to monitor and for viewing from a distance.
  • Double digital display system provided to measure the Infant temperature and to set the required temperature.
  • Feather touch keys provided for easy operation.
  • Bar graph LED system provided to indicate the heater output.
  • Manual control system provided.
  • Fault Indications with alarm for Baby probe failure, 1oC temperature high, 1 oC temperature low, High temperature cut-off, Power failure
The Electronic Controller
  • The controller is based on Microcomputerized system
  • Large bright displays are easy to monitor and for viewing from a distance
  • Double digital display system provided to measure the Infant temperature and to set the required temperatureFeather touch keys provided for easy operation
  • Bar graph LED system provided to indicate the heater output
  • Manual control system provided
  • Fault Indications with alarm for
    • Baby probe failure
    • 1oC temperature high
    • 1oC temperature low
    • High temperature cut-off
    • Power failure
Baby Probe
  • Baby probe is made of highly sensitive sensor and is interchangeable, field calibration taken care of by software. The probe is made up of silicon sheathed cable, which allows easy cleaning
Baby Tray
  • The large baby tray is made of stainless steel frame with three side acrylic collapsible walls, trendelenburg & fowler system provided
Observation Lamp
  • A halogen based observation light focus on any area on the bed
Heater
  • Single element CE approved ceramic heater placed in a parabolic reflector
Other Facilities
  • Provision of Oxygen cylinder
  • I V stand provided
  • Monitor tray provided
Physical Parameters Mattress
  • Length :700 mm
  • Width : 500 mm
  • Thickness : 50 mm
  • Working level from ground : 1020 mm
  • Baby tray is tilt angle on either side : +/-8 max
  • Weight Approx : :40 kg
  • Castors : 100 mm with 2 brake wheels and 2 non - brake wheels
Recommended Environmental Specifications
  • Operating temperature range : 20oC to 33oC
  • Storage temperature range : -25oC to 60oC
  • Operating humidity range : 0 - 100% RH
Skin Temperature Probe
  • Range : 28oC to 38oC
  • Accuracy : +/-0.2oC within range
  • Resolution : 1oC
  • Probe interchangeability : +/-0.2oC (Servo)
  • Heater output controllable from 0 to 100% in manual mode (continuously variable)
Phototherapy Unit
  • Supply to each lamp : 12V, 50W
  • Irradiance : 6 - 8 W /cm 2/nm at bed level
Observation Light
  • Halogen based Power required : 12V, 50 W
Electrical Specifications
  • Electrical Supply : 230V 10%, 50 Hz
  • Power consumption with Heater at max. output : 750W
Power Consumption
  • With heater, Phototherapy & observation lamps ON : 1250 W
Electrical Safety
  • As per IEC 60601-1-2 for medical equipments
Note : Best results obtained if air convective current is low