
Company Information
Ask for more detail from the seller
Contact SupplierWe offer Radiant Warmer is innovatively designed to meet thermoregulatory requirements of new born infants who suffer extremes of heat loss. The radiant warmer can be used in delivery rooms and neonatal intensive care units. The micro control based servo control radiant warmer detects minute variations in skin temperature and adjust the ceramic infrared heater output to maintain the infant's temperature at a prescribed pre set level. salient features the controller is based on microcomputerized systemlarge bnght displays are easy to monitor and for viewing from a distancedouble digital display system provided to measure the infant temperature and to set the required temperaturefeather touch keys provided for easy operationledsystem provided to indicate the heater outputmanual control system providedfault indications with alarm forbaby probe failure1 oc temperature high1 oc temperature lowhigh temperature cut-offpower failure baby probe baby probe is made of highly sensitive sensor and is interchangeable, field calibration taken care of by software the probe is made up of silicon sheathed cable, which allows easy cleaning baby trolley (optional) a detachable baby trolley which consists of large baby tray & is made of stainless steel frame with three side acrylic collapsible walls. Trendelenburg & fowler system provided observation lamp a halogen based observation light focus on any area on the bed heater smgle element (e approved ceramic heater placed in a parabolic reflector other facilities provision of oxygen cylinderi v stand providedmonitor tray provided physical parameters length : 700 mmwidth : 430 mmthickness : 25 mmworking level from ground : 900 mmbaby tray is tilt angle on either side : +/-8omaxweight approx : 35 kgcastors : 50 mm with 2 brake wheels and 2 non - brake wheels recommended environmental specifications operating temperature range : 200oc to 33ocstorage temperature range : -25oc to 600ocoperating humidity range : 0- 100%rh skin temperature probe range : 28oc to 38ocaccuracy : +/-0.2oc within rangeresolution : 0.1ocprobe interchangeability : +/-0.oc (servo)heater output controllable from 0 to 100% in manual mode (continuously variable) observation light halogen based power required : 230v, 50 w electrical specifications electrical supply : 230v ± 10%,50hzpower consumption with heater at max. Output : 750w power consumption with heater, observation lamps on : 800w electrical safety as per iec 60601-1-2 for medical equipments note : best results obtained if air convective current is low.