Our Products
IEWI have developed various versions of the IBC Wash Stations keeping theapplication of the client mind as also the constraints that are normally existingat the site in the wash area.The IBC is first loaded on a specially designed trolley/ monorail . The door ofthe IBC wash station which is in the non-sterile area, is then opened andthe IBC is guided into the wash roomafter which is the door closes. The trolley mounted IBC is then latchedonto a conveyor mechanism, which is anin-built feature of the IBC wash station.The conveyor guides IBC and locks it atthe point of washingin the washing machine, the bank of sensors send thetrigger to the PLC which starts washingcycle. A specially designed self-rotary cleaning nozzle is introduced into the IBC.The pressure generated by the special purpose high pressure multistage pumpuses the nozzle to spin on its verticalaxis with a velocity sufficient to ensurea thorough cleaning
Industrial Equipwash Inc. manufacture barrel/drum washing units for cleaning of drums, barrels in bulk drugs, chemicals, pesticides etc The Drum Cleaning station consist of:A washing frame which support the cleaning compartment made of SS 316 grade. A cleaning lance, self rotating, covering 360 rotating action, self driven, powered by a multistage pump for internal cleaning.Array of cleaning nozzles for external cleaning with knife edge spray nozzles designed to wash external surfaces and custom made to reach even the most remote corner.
The range of sanitary stainless steel bends, tees , expanders, manifolds, pipe holders, reducers, hose nipples, sight glass and custom designed components are manufactured to tight tolerances of roundness and perpendicularly to facilitate accurate fabrication and orbital welding.The design of fittings has a flush, crevice-free joints, particularly suitable for in-place cleaning. End Connections : SMS, DIN, TC Clamp, butt-weld; flanged (special design with mating flanges that butt-weld to the tube). Material of Construction: SS 304, SS 304L, SS 316 and SS 316L. Size Range: 1"(25.4 mm), 1 "(38.5 mm), 2"(50.8 mm), 2" (63.5 mm), 3"(76.2mm), 4"(101.6 mm)) DOWN LOAD PDF CATALOGUE |
IEWI offer sanitary stainless steel centrifugal pumps for pharma, drugs, food, beverage, dairy, cosmetics and chemical industries. Pumps are monobloc design and manufactured from SS 304 /SS 316 bar stock/sheet metal. All product contact parts(casing, impeller) are in stainless steel, duly electropolished and free from uncleanable pockets.Pumps are fitted with mechanical seals externally mounted. Pumps can be dismantled and assembled in minutes without tools. Pumps can be cleaned and steam sterilised. Drain ports or sampling valves are provided on request.
End connections offered include triclamp, DIN, SMS, flanged and butt-weld Pumps are offered in capacities 3000 litres/hour to 6000 litres/hour
IEWI offer cleaning nozzles for a range of cleaning applications Whether you require a simple water rinse or cleaning with detergent, or a high impact wash or sanitising with oxidising to reduce microbial contaminants, we have a nozzle for you.The nozzles are available in various designs including solid cone nozzles, V-jet nozzles, flat-jet nozzles, high -impact nozzles & self-rotating nozzles.
SPECIFICATIONS
Pressure : 2 Kg/cm2 or as specified
Flow rates: 5 LPM to 1250 LPM
End connections 1/8 to 4 BSP/BSPT/ NPT
Moc : SS 304, SS 316 Teflon , PVC
Industrial EquipWash Inc. offer Stainless Steel Clean Room / Change Room Furniture including Apron Cabinets, Shoe Racks, Dies & Punches Cabinets, Lockers, Sinks, Sink Tables, Hand Wash Systems, Racks, Tables, Chairs, Cross-over Bench, Multi-purpose Trolleys, Dust bins, Tubs and custom designed furniture. All furniture is fabricated from SS 304/SS 316 duly ground and buffed to pharma standards.
IEWI offer FBD Bag wash station keeping the application of the client in mind as also the constraints that are normally existing at the site in the wash area. The wash cycles follow the recipe set in the PLC normally would consist of wash cycles which can be decided by the user depending either on the size of the fbd bag and the SOP of the wash cycle to be followed. Typical wash cycle includes potable water rinse, hot water rinse, detergent wash, hot air drying etc. The recipe management of the PLC allows the user the flexibility of even selecting the sequence of wash cycles and time required to complete each wash. The FBD bags are first loaded onto a specially designed machine. The the FBD bags along with the hanger are locked into place on the inside of the washing container. Once the fbd bags hanger is properly located in the machine, the PLC starts the washing cycle through preset receipe. Internal cleaning is achieved through cleaning lances located inside the bags. External cleaning of the finger bag is done with the help of strategically positioned flat V-jet nozzles. |
GLASS FLASK WASHING STATION
This machine is used for cleaning and sanitizing the external and internal surfaces of glass flasks. The flasks to be washed are manually loaded horizontally onto the machine frame. It is then tilted to a vertically inverted position The outer door is then closed to prevent water from spraying outside. A specially designed nozzle, which is mounted on a pneumatic cylinder is then inserted into the barrel. This pneumatic cylinder is operated with the help of a control panel provided on the machine. CIP liquid is then pumped into the flask for cleaning internal & external surfaces. Internal cleaning is done with the help of nozzles and the external cleaning is done with the V jet nozzles. The drain water is then drained through a drain port in the machine. As an optional feature a steam sterilization can be done for validating the flask after CIP is carried out. After the CIP cycles are over the nozzle is lowered the outer door is opened and the flask is then titled to a horizontal position and removed
The Split Butterfly Valves are designed a to minimize atmospheric contamination during transfers of powders. High containment can be achieved during powder charging, discharging, and sampling . This applies particularly to dust free charging and discharging of laboratory, pilot scale and production process. Construction and Working The Split Butterfly Valvesconsists of two separate halves : a driving half (Active) and a driven half (Passive). The System is such that any passive will fit into any Active (non-pressure rated or pressure rated ) of the same size.Within the Active and passive assemblies are two halves of the butterfly type disc. The two halves (Active and Passive) mate together along their axis of rotation. Sealing between the discs is achieved via a metal-to-metal seal at the outside edge of the discs. The disc and shaft design of each half is a solid one-piece component, eliminating crevices and increasing strength when coupled. The coupling process is achieved by inserting the Passive into the Active unit. This can only be successfully carried out in one orientation, as there are four, non equi-spaced pegs about the circumference of the Passive, which locate within slots in the Active body. When the Passive is correctly sitting in the Active, a sprung pin is depressed by one of the Passive pegs, this allows the locking ring to be rotated into the operating position. The locking ring is machined with four cam angles, which force the Passive further down into the active body. This enables the seats on the Passive & Active to come together to form a seal. The disc sealing element is elastomeric which precisely locates into the body and is not bonded, enabling easy removal, cleaning, and replacement Both Active and Passive units are fitted with mechanical safety interlocks, which in normal operation prevent either Active or Passive from being opened when the two halves are not coupled together. Both manual wrench or actuation designs are offered. Advantages of the contamination free isolation valve systems : Full protection for operator, product and environment. No cross-contamination . Reproducible containment levels over long periods. Quick docking and undocking cycle ( View Complete Details Stainless Steel Service Shaft Pendent
CIP/SIP MODULES
STERILIZATION IN PLACE (SIP) SYSTEMS
Spray BallTheSpray Ballis a simple yet a highly effective device for the internal washing of process and storage tanks. A Spray Ball, powered by the cleaning fluid, generates a high pressure spray to clean every part of the vessel. There is only one moving part and no maintenance whatsoever . No lubrication is necessary which prevents any risk of oil or grease contamination of the product, making the spray ball ideally suited for hygiene sensitive applications. SANITARY STAINLESS STEEL FILTERSThe stainless-steel cartridge housings are designed for final ultra- filtration of liquids or gases through cartridge filters. The housings are designed to ASME code standards, All welds are ground flush, and polished to a high-quality sanitary finish. The housings have a removable cartridge manifold to allow for complete disassembly of the downstream side, and ease of cleaning of all fluid contact surfaces. The housings are in-line steam-sterilisable These housings can accept any cartridge element in various configurations of DOE, code '7', BSP male thread, or tie rod . Water Saver NozzleHeavy duty, stainless steel, Water Saver Nozzle is designed for cleaning applications in pharma, food, dairies, breweries, beverage & cosmetics. It does a better job with the least amount of water. The precision made nozzle enables the operator to get any type of stream of water to do jobs by simply pressing the lever. A slight spray is sent forth with slight pressure on the handle. The nozzle automatically shuts off the moment the lever is released, thereby eliminating water wastage. The nozzle is provided with molded rubber jacket to avoid thermal shock. HAND SANITISER AUTOMATIC IPA DISPENSERThi Hand Sanitizer automatically dispenses disinfectant(isoproyl alcohol) onto your hands. The dispenser prevents you from touching unhygienic levers, taps knobs & soap cakes. Thus preventing cross contamination and maintaining complete cleanliness . Overflow Top Reactor SamplerExtracts a liquid sample from reactors and vessels via a dip pipe. Sample is representative, fixed volume and cannot overflow the sample bottle. Large valve ports and minimal dead space prevent plugging. All wetted parts are made from corrosion resistant materials. Shoe Cover DispensersAutomatic shoe cover dispensers eliminate the problem for manual wearing shoe cover on foot and avoid carrying any contamination to clean room/ sterile areas. Suitable for pharmaceuticals, electronics, Food I, Cosmetic , Hospitals, & Allied industries. Dimensions: 47 cm (l) x 28 cm(w) x 18 cm (h) Floor DrainsIEWI offer a range of floor drains suitable for light to medium duty loads, incorporate advanced designs, high quality and ease of installation - at extremely competitive prices. To complete the line of drains, IEWI offers a range of gulleys and trenches in stainless steel The unique seal design prevents foreign particles & cockroach present in the discharge pipe from entering back in to the sterile areas TURBOJET TANK CLEANING NOZZLETURBOJET TANK CLEANING NOZZLE HOSE DOWN WASH UNIT
Sanitary Stainless Steel ValvesDiaphragm valvesare designed to meet 3A standards. The valves are manufactured from SS 316 / SS 316L bar stock/investment castings Diaphragm is food grade EPDM or silicon or viton. End connections can be tri-clamp, flanged or butt weld. The smooth contoured body, pocketless design and electropolished interior surface prevents accumulation of process fluids and contaminants.Can be steam sterilised.GMP Loop Valvecan be utilized to eliminate dead legs in the design of point of use outlets in atypical WFI/DM piping distribution loop. As the process fluid flows through the valve body, as demand warrants, the valve isopened providing an uncontaminated sample which may accumulate in outlets greater than 3D. The outlet can also be utilised as a steam condensate drain or as a divert port. The valve has been modified to accept a third port of the same diameter or smaller, positioned adjacent to the bottom of the valve. Typically the GMP valve is oriented in the vertical position. For horizontal process applications, the sterile Tell Us What are you looking for? Will call you back