Our Products
We offer a complete product range of Feedwater Heaters and In-Line Venturi Steam Desuperheater
The needs of the power generation industry include year-in and year-out reliability, optimum performance for maximum efficiency, and absolute on-time delivery to meet plant outage schedules.
All of the Jet Flow Feed Water Boiler Heaters are designed in accordance with HEI standards, TEMA and ASME codes. Jet Flow uses state-of-the art computer programs to perform the thermalhydraulic and mechanical design of each Feed Water Heater we fabricate.
Jet Flow designs and manufactures both Low Pressure (LP) and High Pressure (HP) feed water heaters which may be installed either vertically or horizontally, depending on the plant design requirements.
Each Jet Flow LP / HP Feed Water Heater will contain from one to three separate heat transfer areas of zones including the Condensing, De-superheating and Sub-cooling zones. Our heaters can be provided with multiple zones within the shell side:
Jet Flow Feed Water Heaters are designed for specific thermal conditions and manufactured for a singular purpose. Whether it be sophisticated designs involving extreme superheat, abnormal flow conditions or dissipation of high energy fluids.
In addition, Jet Flow provides innovative and practical concepts to ensure peak heater performance from installation to testing through full or part load operation. We offer a multitude of design configuration for de-super heater and drain cooler zones as well as the latest channel closure techniques.
All shell & tube heat exchangers, irrespective of the type of service for which they were designed, must withstand severe service conditions. The service life of feed water heaters, however, is one of the toughest because of the longevity and reliability factors inherent in power plant equipment designs. Jet Flow thorough understanding of these factors enhances its ability to communicate clearly with power design engineers. Jet Flow designs enable power engineers to anticipate maximum efficiency from the turbine extraction steam in preheating the boiler feed water.
Scope offering:
A version of single venturi desuperheater has the same operating conditions. can be mounted easily and quickly in the exisiting pipeline. The unit can be clamped between two flanges. Sizes are between 1 1/2” to 30”
Specification
| Material |
|---|
| A182 GR F11 / F22 / F91 |
| A182 GR F11 / F22 / F91 |
| A105 |
| DIN 1.4122 PLASMA NITRIDED / INCONNEL 718 |
| DIN 1.4122 PLASMA NITRIDED / INCONNEL 718 |
| DIN 1.4122 PLASMA NITRIDED / A 182GR F11 / F22 / F91 ST |
| A 182 GR F11 / F22 / F91 |
| DIN 1.4122 PLASMA NITRIDED |
| DIN 1.4122 PLASMA NITRIDED / INCONNEL 718 |
| X120 Cr 29 |
| GRAFOIL |
| A182 GR F11 / F22 / F91 |
| A 182 GR F11 / F22 / F91 |