Our Products
Our Complete range of products are Shielded Multicore Flexible Cable and Shielded Instrumentation Cable.
Multicore Flexible Cables consist of multiple insulated conductors wrapped together in a single outer jacket, helping avoid tangled wiring by replacing multiple individual wires with one organized cable. These cables are ideal where flexibility, compact wiring, and signal integrity are required.
Conductors are made from electrolytic grade annealed copper, bunched as per Class 5 of IS 8130:2013. Manufactured in compliance with IS 694:2010, cables are available from 0.25 sq.mm to 400 sq.mm.
Note: A single 3-phase cable is not a multicore cable; cables containing two or more separate 3-phase conductors are classified as multicore cables.
Types of Multicore Flexible Cables
Shielded Multicore Cable
Braided Shield Cable
Foil Shield Cable
Unshielded Multicore Cable
Technical Data
| PVC insulated Bare copper conductor 600v / 1000v sheated Multicore Felixble cables | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Area (Sq. mm.) | Insulation Thickness (mm) | Core Diameter (mm) | Max. DC Resistance Ohm/Km at 20°c | Sheat Thickness (mm) | Approx Overall Diameter (mm) | Current Rating (Amps) | ||||||
| 2 Core | 3 Core | 4 Core | 2 Core | 3 Core | 4 Core | 2 Core | 3 Core | 4 Core | ||||
| 0.5 | 0.6 | 2.2 | 39 | 0.9 | 0.9 | 0.9 | 6.08 | 6.41 | 6.96 | 4 | 3 | 3 |
| 0.75 | 0.6 | 2.4 | 26 | 0.9 | 0.9 | 0.9 | 6.44 | 6.8 | 7.39 | 7 | 6 | 6 |
| 1 | 0.6 | 2.6 | 19.5 | 0.9 | 0.9 | 0.9 | 6.78 | 7.17 | 7.8 | 12 | 10 | 10 |
| 1.5 | 0.6 | 2.8 | 13.3 | 0.9 | 0.9 | 1 | 7.22 | 7.65 | 8.34 | 16 | 14 | 14 |
| 2.5 | 0.7 | 3.5 | 7.98 | 1 | 1 | 1 | 8.64 | 9.16 | 10.01 | 20 | 18 | 18 |
| 4 | 0.8 | 4.3 | 4.95 | 1 | 1 | 1 | 10.08 | 10.94 | 11.98 | 27 | 24 | 24 |
Technical Data
| PVC insulated Plain copper conductor 600v / 1000v sheated Multicore Felixble cables | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Area (Sq. mm.) | Insulation Thickness (mm) | Core Diameter (mm) | Max. DC Resistance Ohm/Km at 20°c | Sheat Thickness (mm) | Approx Overall Diameter (mm) | Current Rating (Amps) | ||||||
| 2 Core | 3 Core | 4 Core | 2 Core | 3 Core | 4 Core | 2 Core | 3 Core | 4 Core | ||||
| 6 | 0.8 | 4.8 | 3.3 | 1.1 | 1.2 | 1.2 | 11.36 | 12.28 | 13.46 | 34 | 30 | 30 |
| 10 | 1 | 6.3 | 1.91 | 1.3 | 1.4 | 1.4 | 14.5 | 15.66 | 17.28 | 44 | 39 | 39 |
| 16 | 1 | 7.3 | 1.21 | 1.4 | 1.4 | 1.4 | 16.94 | 18.06 | 19.88 | 61 | 55 | 55 |
| 25 | 1.2 | 9.1 | 0.78 | 1.4 | 1.5 | 1.6 | 20.48 | 22.1 | 24.58 | 69 | 60 | 60 |
| 35 | 1.2 | 10.1 | 0.55 | 1.6 | 1.6 | 1.7 | 22.7 | 24.85 | 26.98 | 88 | 77 | 77 |
| 50 | 1.4 | 11.9 | 0.39 | 2 | 2 | 2 | 27.04 | 28.89 | 31.86 | 116 | 102 | 102 |
| 70 | 1.4 | 13.9 | 0.27 | 2.2 | 2.2 | 2.2 | 31.48 | 33.65 | 37.15 | 155 | 140 | 140 |
| 95 | 1.6 | 16.3 | 0.21 | 2.4 | 2.4 | 2.4 | 35.94 | 38.43 | 42.45 | 190 | 165 | 165 |
Shielded Instrumentation Cables are specially designed for accurate and interference-free transmission of low-level electrical signals. These cables use aluminum foil shielding with a copper drain wire (ATC) to provide excellent protection against electromagnetic and radio frequency interference.
Manufactured in conductor sizes ranging from 0.25 sq.mm to 4.0 sq.mm, these cables conform to BS 5308 (Part I & II), IEC 189, IS 1554 (Part 1):1988, and VDE 0815 standards.
Available from single core / single pair up to 100 cores or 50 pairs, they are widely used in critical control, measurement, and communication systems where signal integrity is essential.
Applications
Data Acquisition & Control Systems
Computer Networking & PA Systems
Digital Control, Measuring & Communication Systems
Signal Transmission in Noise-Prone Environments