Element Type : Wire wound ceramic encapsulated, Wire-wound glass encapsulated, Thin film ceramic encapsulated
Configuration : Simplex/ Duplex
Wire Configuration : 2, 3, 4 Wire
Protection Sheath Material : SS304, SS316, SS310, Inconel 600/800, Monel
Thermocouples are temperature sensors made up of two dissimilar metals which are joined at one end forming a hot junction and the open wire end acting as the cold junction, the hot junction is in contact with the process. When the measuring point i.e. hot junction gets heated themore...
Features : High accuracy, repeatability. High insulation resistance (>100 M ohm @500 VDC at 250C) Fast response Mineral insulated construction enables the sheath to be bent / routed to suit installation without affecting performance.
Resistance Temperature Detector(RTD) used for temperature measurement -50 to 400 Deg.C. The system accuracy begins with proper primary sensor selection. Various considerations apply to the design of RTD assemblies. The element should be protected from shock and vibration, yet fremore...
Cost effective solution for acceleration and velocity measurement. Can be interfaced with standard monitoring systems which can accept 100 mVg or 3.99mVmmsec sensitivity inputs. With working principle basd on peizoelectricity, the life of sensor and accuracy become the most impormore...
Cost effective solution for acceleration and velocity measurement. Can be interfaced with standard monitoring systems which can accept 100 mVg or 3.99mVmmsec sensitivity inputs. With working principle basd on peizoelectricity, the life of sensor and accuracy become the most impormore...
Temperature data can be stored in PC and online thermograph can be obtained for analysis. : Temperature measuring range: 0°C to 250°C or as per requirement with maximum ±1° C error.
Accurate monitoring of Temperature through RTD (Pt-100) temperature sensor. : Provision for Upper and Lower limit setting of temperature.alongwith audio-visual annunciation.
Temperature plays most critical role at all stages of tea processing starting from the plucking. Most Tea factories use Thermo-couple based sensors for Temperature monitoring and control. Thermocouple based sensor are not very accurate and temperature measurement by this method imore...
L.D. BHATTAR & CO SOURCE TO ALL CABLE REQUIREMENTS Home About Us Products Enquiry Contact Us As the generated voltage in the thermocouple circuit depends upon the difference of temperature between the hot and cold junction of the thermocouple, the accuracy of the measured tmore...
1.rtd sensor, make - tempix, length -12"below head , od - 8mm , 12 "bsp connection, temperature range 400 deg. and 2.thermocouple , type - k , length 12" below head , od - 8 mm , connection - 12 bsp , temperature range - 800 deg. more...
Thermocouple assembly with fixed adjustable connection having customized design and length with weatherproof flameproof explosion proof with moc ss 304, 316, 316l, inconel etc. more...
Special Features : In-Built Lead wire Compensation In-Built Pt100 Lineariser. Two Wire Current Transmitter. Low Operating Power. Higher Loop Impedance Widely Adjustable Zero & Span. Field Mounting Panel Mounting Optional Local Indicator. more...
Special Features : Scan Independent Channel Monitoring. Field Programmable Group Association. Password Protected Program Mode. Password Protected Software Calibration. In-Built Sensor Lineariser. Non Volatile User’s Program Retention. Audible Alarm. TC Cold Junction Compensatiomore...
A thermocouple is fundamentally a pair of electrical conductors of dissimilar metals so joined as to produce a thermal emf when the junctions are held at different temperatures. The two junctions are termed as 'Hot' and 'Cold' junction. The cold junction is terminated on ther temmore...