Post Buy Requirement
LT
Mohali, Punjab, India
Add Review

Our Products

  1. Cupboard 3 Products available
  2. Laboratory Equipments 3 Products available
  3. Optical & Laser Instruments 3 Products available
  4. Measuring Instruments & Equipment 11 Products available
  5. Testing Equipments 7 Products available
  6. Generators 4 Products available
  7. Testing Equipment 30 Products available
  8. Others 70 Products available

Other Products / Services

High Precision Rotation Luminaire Goniophotometer

LSG-1800BLSG-1700BLSG-1600B Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B is an update version for LSG-1800, the LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.

LSG1800B High Precision Rotation Luminaire Goniophotometer
View Complete Details

Rotation Luminaire Goniophotometer

LSG-1800LSG-1700LSG-1600 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1800, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.

LSG1800B High Precision Rotation Luminaire Goniophotometer
View Complete Details

Electrostatic Discharge Simulator

ESD simulator (Electrostatic Discharge Generator or Electrostatic Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GBT17626.2, GBT17215.301 and GBT17215.322. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. ESD61000-2ESD61000-2A has LCD display in both English and Chinese, they equipped with an infrared remote control which can allow you do the test in some special place.
View Complete Details

Emi Test System

KH3961 is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic Interference) testing. The KH3961 is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System KH3961 fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
View Complete Details

Coupling Decoupling Network

EMI Receiver equipped with couplingdecoupling network is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30300MHz.
View Complete Details

Absorbing Clamp

EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30300MHz
View Complete Details

Voltage Probe

EMI Receiver equipped with voltage probe can test disturbance voltage from load terminals or control terminals.
View Complete Details

12.5 Mm Jet Nozzle

  • FEATURES Instrument manufactured according to the relevant standards Pressure gauge (included) Digital Flow meter (upon request) Produced with high quality material and correct dimensions Etc.
Jet Nozzle IPX 56 is designed to perform tests in large and small-scale products. It is a great option when a portable tester is necessary. Jet Nozzle IPX 56 comes with two nozzles (6.3mm for IPX5 and 12.5mm for IPX6) Jet Nozzle IPX 56 meets the testing needs of industry standards such as IEC 60529.
View Complete Details

6.3mm Jet Nozzle

The jet nozzle is designed and manufactured in accordance with IEC60529 clause IPX5 and IPX6. It is used for the waterproof test of the electric appliance.

Test for second charateristic numeral 5 with the 6.3 mm nozzle
The test is made by spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as shown in figure 6.
The conditions to be observed are as follows:
Internal diameter of the nozzle:6.3 mm;
Delivery rate:12.5 Lmin5%;
Water pressure: to be adjusted achieve the specified delivery rate;
Core of the substantial stream: circle of approximately 40 mm diameter at 2.5 m distance from nozzle;
Test duration per square metre of enclosure surface area likely to be sprayed:1 min;
Minimum test duration: 3 min;
Distance from nozzle to enclosure surface: between 2.5 m and 3 m.
Test for second characteristic numeral 6 with the 12.5 mm nozzle
The test is made by spraying the enclosure from all practicable directions with a stream of water from a standard test nozzle as shown in figure 6.
The conditions to be observed are as follows:
Internal diameter of the nozzle:12.5 mm;
Delivery rate: 100 Imin 5%;
Water pressure: to be adjusted to achieve the specified delivery rate
Core of the substantial stream: circle of approximately 120 mm diameter at 2.5 m distance from nozzle;
Test duration per square metre of enclosure surface area likely to be sprayed: 1 min;
Minimum test duration: 3 min;
Distance from nozzle to enclosure surface: between 2.5 m and 3 m.
View Complete Details

Goniophotometer With Rotating Mirror

Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Lsocandela Diagrams, Efficient Luminescence Angle, etc.
View Complete Details

Goniophotometer For Automotive And Signal Lamps

Measurement Principle
LSG-1950 is the CIE A- Goniophotometer . The photometer head keeps static and face to the test sample while the test sample rotates around both horizontal axis and vertical axis, so the luminous intensity and illuminance of the tested lamp or luminaires can be tested.
View Complete Details

LSG-1950S Automatic Test System

LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors, LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.

Rotations of test samples around both vertical axis (-90+90) and horizontal axis(-35+35)
Accuracy of angle: 0.1
Resolution of angle: 0.01
Photometer detector: CIE class A (standard class) accuracy
All software control, high intellectual faculties and simple operation

By selecting different test scheme, replace testing different types of lamps rapidly.
View Complete Details

High Precision Rotation Luminaire Goniospectroradiometer

LSG-1800BCCDLSG-1700BCCDLSG-1600BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
View Complete Details

Rotation Luminaire Goniospectroradiometer

LSG-1800CCDLSG-1700CCDLSG-1600CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
View Complete Details

Compact Goniophotometer

The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree.

Option Function: The LSG-1200A can work with a Digital Power Meter (LS2012 DC & AC Power Meter or LS2010 Harmonic Analyzer) and LSP-500VA AC Power Source.
Specification:

Meets the requirements of IEC, CIE and LM-79 standards

Measures beam angle automatically: staple half intensity angle as well as 14 intensity angle, 34 intensity angle and 110 intensity angle which meets the special requirements.

Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux
View Complete Details

High Precision CCD Spectroradiometer

LMS-9000ALMS-9000B is according to LM-79 clause 9.1. It is designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.

LMS-9000B is quick test with high accuracy, it used in Scientific lab test. Due to the test speed and LMS-9000B can work with LSG-1600BLSG-1800BLSG-1900LSG-2000 goniophotometer to do the Spatial color and Spectrum test.
View Complete Details

Scientific Grade CCD Spectroradiometer

LMS-8500 Scientific Grade CCD Spectroradiometer fully meets Energy Star IESNA LM-79 and GBT 24824 standards etc. It is test for CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the scientific grade measurement accuracy. LMS-8500 is composed of Concave Average Diffraction Grating and Scientific Grade CCD, and uses unique stray light control technology, wide dynamic linear technology, precision CCD electronic drive technology and complex matrix software technology, the instrument can be traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST transfer standards.

LMS-8500 can work with LSG-1800LSG-1700LSG-1600 series Goniophotometer, to test special CCT Distribution and other Spectral color parameters.
View Complete Details

Ccd Spectroradiometer

LMS-8000ALMS-8000 LED Measurement System is an automated measurement system for identifying the performance of individual LED. It is designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.

The LMS-8000ASLMS8000S is updated on LMS-8000ALMS-8000. It can connect with two integrating spheres: the big one is for LED luminaries and the small one is for LEDs & LED modules. The software can be chosen between the two integrating sphere to test. This new technology can save a lot of time and length the use life of the optical fiber & detectors, click to the blog page for more infomation: Technology advanced for LMS-8000 CCD Spectroradiometer
View Complete Details

High Accuracy Spectrophotocolorimeter

This test system is suitable for energy saving lamp, fluorescent lamp, HID lamp (high voltage sodium lamp, high voltage mercury lamp), LED, phosphor photometry and colorimetry analysis and meets the requirements of CIE for the measurement of photometry and colorimetry.

Measure and display the relative spectral power distribution (UV-VIS-NIR)P(), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC.
Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument
Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably
Figure of chroma and color difference in test report can be exchanged freely
Color display and print. The relative spectral power distribution (UV-VIS-NIR)P(), reports both in English. RS-232-C interface, compatible with all kinds of computer
LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer
Range of wavelength: 380nm780nm, (Special:200nm780nm)
Accuracy of wavelength: 0.2nm
Repeatability of wavelength: 0.1nm
Accuracy of chromaticity coordinate: 0.0003(under standard illuminate A)
Spectrum sample interval: 5nm(Special order:1nm)
Luminosity linearity: 0.3%
View Complete Details

Moving Detector Goniophotometer

LSG-1900 Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 requirement. The LSG-1900 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.

Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Lsocandela Diagrams, Efficient Luminescence Angle, etc.
View Complete Details

DC Electronic Load

M9811 is applicated in production line(cell phone charger, cell phone battery, electric vehicle battery, switching power supplier, linear power supplier, LED driver), research insititutes, automotive electronics, aeronautics and astronautics, ships, solar cells fule cell, etc.B.
View Complete Details

LED Spectroradiometeric System

  • Technical Specification: 1) Thermal parameters: Junction temperature, thermal resistance and K factor • Thermal sink range: 5℃ ~ 90℃ • Temperature control system accuracy: ±1℃ • Junction temperature accuracy: ±1℃ Etc.
Thermal parameter is the key index to evaluate the quality of LED. Different temperature will have significant different effects on optical parameters, color parameters, electricity parameters and life of LED. Therefore, design and control of the thermal dissipation are the most important thing for the manufacturers and users. Referring to the relative international standard, TRS-1000 could conduct integration testing on optic, color, electricity and thermal, meanwhile record the changing curve of the parameters at real time.
View Complete Details

Electrical Performance Analyzer

  • Feature Automatically record the changing curve of the parameters with time • Measurement functions: Etc.
  • Measurement Junction temperature, K factor, Forward voltage, Forward current
  • Specifications Output current range: 1 ~ 2000mA • Thermal sink range: 5oC ~ 90oC • Temperature control Etc.
Thermal parameter is the key index to evaluate the performance of LED. Its very important to measure thermal characteristics of high power LED for high reliability LED applications. It will have effect on the optical parameters, electricity parameters and lifetime of LED. Therefore, design and control of the thermal dissipation is the most important thing for the manufacturers and users.
View Complete Details

Optical Path Converter

There are many LED manufactories using two integrating spheres and one spectrophotometer to do test. The previous testing way is: when you use big sphere to test, the customer need to connect the detector cable and optical fiber from the Spectrophotometer to the big sphere, after the calibrating and then you can do the test. When you use the small sphere, you need to take away the detector cable and optical fiber from the big sphere to the small sphere, then need to calibrate again

It is too troublesome to take out the detector cable and optical fiber between the big sphere and small sphere, and you need to calibrate again for every change. The frequent change will also shorten the life of the detector cable and optical fiber.
View Complete Details

Led Optical Aging Test Instrument

LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to standards of IES-LM-80, IES-LM-82, TM-21 and GB2312-80, and the software is developed base on Arrhenius model. LED has the features of long life, but with the different working condition and drive current, its life will be different, but generally the life will be around 50K hours. Differ from the traditional lightsource, LED light will decay gradually rather than extinguish instantly, so in the standard of LM-80, it introduces L70, L50 and etc.
1) L70 (hour): time to 70% lumen maintenance
2) L50 (hour): time to 50% lumen maintenance.
View Complete Details

High Precision Spectroradiometer Integrating Sphere System

  • System Configuration: High Precision CCD Spectroradiometer (LMS-9000B or LMS-9000A), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2012 or LS2010), DC Power Source (DC Series) Etc.
  • Measures Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, etc.
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LEDs quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
View Complete Details

Integrating Sphere Spectroradiometer System

LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LEDs quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.

The LMS-8000S CCD Spectroradiometer can connect with two integrating spheres: the big sphere is for LED luminaries and the small sphere is for LEDs & LED modules. The software can be chosen between the two integrating spheres to test. This new technology advanced can save a lot of time and longer use life the optical fiber & photo detector, the more introduce please visit at: Technology advanced for LMS-8000 CCD Spectroradiometer
View Complete Details

Adjustable Resistance Ballast

  • Specifications Available current range: 0~0.700A • Impedance range: 100~2047Ω • Impedance tolerance range: ±0.5%(Under calibration current). ±1%(Any current between 50% calibration current) Etc.
RB-3 is designed according to the following standard requirements: IEC 60929 (GBT15144), double-ended fluorescent lamp adoptting the IEC 60081 (GBT10682) and the single-ended fluorescent lamp adoptting the IEC 60901 (GBT17262)

The RB-3 works with HFP-800 (High Frequency Power Supply ) and LPS-3 (Auxiliary Power Supply) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube, please click here to learn the more details
View Complete Details

No Go Gauge

Specification:
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality Go and Not gogauge
GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2
GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1
GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2
GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1
GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1
GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8

Please inquiry for more lamp holder or lamp cap via our salesman.
View Complete Details

Integrating Sphere Test System

This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
View Complete Details

High Frequency Power Supply Unit

The HFP-800 works with LPS-3 (Auxiliary Power Supply) and RB-3 (Adjustable Resistance Ballast) to be an IEC Standard Test System which used to test the Frequency Fluorescent Lamp such as T5 Tube. Etc
View Complete Details

Transient Photometer

The Luminous flux, illuminance and Brightness are the most basic physical quantity in photometric test. PH3000 Transit Photometer is developed base on rapid sampling techniques. It applied with 12 Bytes, the maximum sampling rate of 10M Hz high-speed A D which can be achieved rapidly high speed measurement of varying light photometric parameters. Combined with computer can record the sampled waveform. The PH3000 also can used as normal illuminance meter, it can measuring luminous flux, brightness, illuminance and photometric parameters.
View Complete Details

Photometer

Specification:
Flux or Lumen measure range depends on the size of the integrating sphere
Light current measuring range: 0.00510-7A200010-7A
User can do ZERO and Calibrate by operating the keys on the front of panel
Photo Detector: Class 1
High correcting accuracy of photo detector V()
English Software can be run in WinXP or Win7 by RS-232 (option)
View Complete Details

Standard Light Source

OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
View Complete Details

Optical Fiber

Link the spectrophotometer and integrating sphere, i.e. lead the tested light from the sphere to the spectrophotocolorimeter.
View Complete Details

Output Characteristic Analyzer

Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors
Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time
Accuracy: Class 2
Data and curves printable. All the data and curves can be displayed after being connected with PC
View Complete Details

Electronic Ballast Analyzer

The WT3000 Electronic Ballast Tester meets the latest requirements for electronic ballasts in international standards IEC 60929, IEC 60969, IEC 61000-3-2, GBT15144-2005 and GBT17263-1998.
View Complete Details

Input Characteristic Analyzer

4 display windows for V(600V), A(2A), W, PFHz
THD, 0 to 39th harmonic components
Accuracy: (0.4% reading+ 0.1% range+1 digit)
Data and curves printable. All the data and curves can be displayed after being connected with PC
View Complete Details

Programmable Withstanding Voltage Test

The LS9922I is a high-performance testing device special for withstanding voltage and insulation resistance test, allowing setting the output voltage. The warning value, testing time and some other parameters can be set in the software. It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the lab develop research.
View Complete Details

Digital Oscilloscope

The JC Series Digital Oscilloscope was designed and produced by high accuracy electronic components and modules. The test accuracy is world high class. It is used in all kinds of electronic products testing.
View Complete Details

Standard Test Finger

It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
View Complete Details

Ball Pressure Test Device

Made up by the related item according to IEC60695, IEC884-1, GBT5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc.

R=2.5mm Pressure: 20N
Base with thermocouple hole
Material: 304 stainless steel
View Complete Details

Glow-wire Test Apparatus

It is according to IEC60695-2-1, IEC60695-2-10IEC60695-2-13(GBT5169.10-2006GBT5169.13-2006), basic testing methods of Glow wire, basic testing methods of Glow wire device> and UL 746A, IEC829, DIN695, VDE0471, the Glow wire tester ZRS-3H is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. Adopting high-temperature coating spraying on steel structure and imported instrument display, with easy operation, stable performance the equipment is applicable to flame resistance tests of all levels of QC departments and corresponding enterprises.
View Complete Details

Needle Flame Test Device

According to IEC60695-2-2 and IEC60695-11-5, ZY-3 Needle Flame Test is applied in the production and quality control department of lighting instrument, hyperpiesia electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, it is fit for the industry of insulation material, engineering plastics and solid combustible material.
View Complete Details

Lamp Cap Temperature Rise Test System

TMP-L is according to IEC60360-1998 and GB2512-2001(Standard method of measurement of lamp cap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards.
View Complete Details

Automatic Safety Test System

The LS9934LS9935 Automatic Safety Test System is according to GB4706.1, IECEN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It used for luminaries, home application and motor tools safety test in production line or Lab R&D.
View Complete Details

Automatic Double Drop Test Machine

This series drop test bench for measuring the main simulation packages in the transportation, loading and unloading process under drop impact influence, identification package impact strength and packaging design.

The machine wills automatic stop positioning after sample reach up to the sated height position. According to the different size to choice the test distance between tests arms, electric pulse width. The release mechanism of machine are flexible and reliable, to ensure the sample without any external influence during the release of instant and free fall way, and make sure it meet samples dropping requirements.
View Complete Details

Electrodynamic Vibration Generator System

Electrodynamic Vibration Generator System is complied with IEC 60068, IEC68-2-6, JJG189-97, GBT13309-91, GB2423 etc. Full-function computer control, it includes computer and printer, connect computer to do control, store, record and print function.
View Complete Details

Salt Spray Test Machine

The Salt Spray Test MachineChamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products.
View Complete Details

Sulfur Dioxide Test Machine

  • Specifications • Temperature range: RT+5~55℃(Can be customized according to test demand) • Temperature fluctuation: ±0.5℃ • Temperature uniformity: ±2℃ • Relative humidity: 75~98%RH Etc.
This instrument is designed according to GBT2423.19-1981, GBT2423.33-2005, ISO6988(replaced DIN50018:1988-06), DIN50900, DIN53210 and EC, MIL, ASTM etc to do sulfur dioxide gas corrosion test.
Model Work Room Size (mm) Exterior Size (mm) Voltage Power (KW)
SQ-150 450X600X400 800x1070x1050 AC220 2.5
SQ-250 600x900x500 870x1400x1150 AC220 3
SQ-750 750x1100x500 1030x1680x1260 AC220 4
SQ-010 850x1300x600 1160x2000x1390 AC380 6
SQ-016 850x1600x600 1280x2320x1500 AC380 7.5
SQ-020 900x2000x600 1220x2530x1410 AC380 9
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Dharmendra Chauhan (LED Testing Equipment Suppliers)
  • Plot No. 362, Industrial Area, Phase II, Phase 2, Mohali, Punjab - 134113
  • Share us via