Contact SupplierMonopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad)
Bipolar diathermy is the emitance of the HFAC from the electrosurgery diathermy down one prong of a bipolar forcep through the tissue that has been placed between the forcep tips and returned to the diathermy via the second prong. Bipolar diathermy does not require a dispersive electrode (patient return pad).
Surgical instrument india has three effects on body tissue:
Each of these processes generates smoke plume which contains:
To minimize associated health hazards, specially designed smoke evacuation systems should be used where available and surgical filtration masks donned for all surgical procedures.
The Electrosurgery Unit (ESU) should only be use by members of the peri-operative team deemed competent.
The diathermy surgery should be protected from spills. Fluids should not be placed on top of the ESU
The dispersive electrode should be the appropriate size for the patient’s weight and an electrode should never be cut to size
Only those active electrodes recommended by the manufacturer should be used. If an adapter is used it should be one that is approved by the manufacturer and does not compromise the generator's safety features.
After the patient is positioned on the operating table, the dispersive electrode should be placed on a clean, dry intact skin surface over a large, well perfused muscle mass
The dispersive electrode should not be placed over.
The electrode should be positioned as close to the operative site as possible
The dispersive electrode should be connected to the ESU prior to draping to ensure adequate contact & then the lead disconnected from the ESU temporarily to allow for the draping of the patient and the positioning of the surgeon
Mono Polar/Bipolar Surgical Diathermy
AYU 250 ANL is a high frequency Electro Surgical Unit Micro controller based innovative design, together with high reliability makes AYU 250 ANL Electro Surgical Diathermy unit the most favorable choice of doctors. The technical ability of the unit is combined with patient's safety that are of prime importance both for patient and the user. The AYU 250 ANL Electro Surgical Diathermy is designed with SMPS power supply which provides particular safety and reliability. AYU 250 ANL is user friendly Electro Surgical unit.
SAFETY IN USE
The Technical conceptions of the AYU 250 ANL meet the requirements of highly refined Electro Surgical techniques all national and international safety standards are confirmed. The micro function and knob allows for an instant variation in the output power for more delicate application such as neurological or micro surgery.
Ortho Peallic
Dermatology
Otolaryngology
Ophthalmology
Ginaecology
Aesthetics
Vascular Disease
MODE | RATED LOAD (OHMS) | MAXIMUM POWER(WATTS) | |
Monopolar Cut |
Pure Blend |
300 300 |
250 180 |
Monopolar Coag. |
Force Soft |
300 300 |
180 150 |
Bipolar Cut |
Pure Blend |
100 100 |
100 70 |
Bipolar Coag |
Force Soft |
100 100 |
70 50 |
Unit Size - L*W*H - 335x330x125 mm
Box Size - L*W*H - 430x405x280 mm
Net Weight - 5kg.200gm Gross Weight - 10kg . 500gm