Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Electrosurgical Cautery Machine

Listing ID #3797513

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1998

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad)

 

Bipolar diathermy is the emitance of the HFAC from the electrosurgery diathermy down one prong of a bipolar forcep through the tissue that has been placed between the forcep tips and returned to the diathermy via the second prong. Bipolar diathermy does not require a dispersive electrode (patient return pad).

 

Background
 

Surgical instrument india has three effects on body tissue:

  • cut - generation of heat destroys tissue cell
  • coagulation - tissue cells contract to increase normal clotting
  • fulguration - cell walls destroyed through dehydration

 

Each of these processes generates smoke plume which contains:

  • chemical by-products (eg toluene, acrolein, formaldehyde, benzene and hydrogen cyanide)
  • intact cells, cell parts and intact viral DNA
  • viable bacteria, including mycobaterium tuberculosis, have also been cultured

To minimize associated health hazards, specially designed smoke evacuation systems should be used where available and surgical filtration masks donned for all surgical procedures.

 

Prior to use
 

The Electrosurgery Unit (ESU) should only be use by members of the peri-operative team deemed competent.

  • The ESU should be inspected and safety features tested (eg lights, activation patient return electrode sound indicator) before each use
  • All cables and electrodes must be checked prior to use to ensure insulation is intact
  • Any problems must be reported to the Biomedical Engineering Department immediately.
  • The volume of the activation sound indicator should be maintained at an audible level

 

General use
 

The diathermy surgery should be protected from spills. Fluids should not be placed on top of the ESU
The dispersive electrode should be the appropriate size for the patient’s weight and an electrode should never be cut to size
Only those active electrodes recommended by the manufacturer should be used. If an adapter is used it should be one that is approved by the manufacturer and does not compromise the generator's safety features.
After the patient is positioned on the operating table, the dispersive electrode should be placed on a clean, dry intact skin surface over a large, well perfused muscle mass

The dispersive electrode should not be placed over.

  • a bony prominences
  • implanted metal prosthesis
  • areas distal to a tourniquets
  • scar tissue
  • hairy surfaces
  • pressure points/areas

 

The electrode should be positioned as close to the operative site as possible
The dispersive electrode should be connected to the ESU prior to draping to ensure adequate contact & then the lead disconnected from the ESU temporarily to allow for the draping of the patient and the positioning of the surgeon

 

Mono Polar/Bipolar Surgical Diathermy
AYU 250 ANL is a high frequency Electro Surgical Unit Micro controller based innovative design, together with high reliability makes AYU 250 ANL Electro Surgical Diathermy unit the most favorable choice of doctors. The technical ability of the unit is combined with patient's safety that are of prime importance both for patient and the user. The AYU 250 ANL Electro Surgical Diathermy is designed with SMPS power supply which provides particular safety and reliability. AYU 250 ANL is user friendly Electro Surgical unit.

SAFETY IN USE
The Technical conceptions of the AYU 250 ANL meet the requirements of highly refined Electro Surgical techniques all national and international safety standards are confirmed. The micro function and knob allows for an instant variation in the output power for more delicate application such as neurological or micro surgery.

 

  • Ortho Peallic

  • Dermatology

  • Otolaryngology

  • Ophthalmology

  • Ginaecology

  • Aesthetics

  • Vascular Disease



  MODE RATED LOAD (OHMS) MAXIMUM POWER(WATTS)
Monopolar
Cut
Pure
Blend
300
300
250
180
Monopolar
Coag.
Force
Soft
300
300
180
150
Bipolar
Cut
Pure
Blend
100
100
100
70
Bipolar
Coag
Force
Soft
100
100
70
50

Unit Size      -     L*W*H - 335x330x125 mm
Box Size      -     L*W*H - 430x405x280 mm
Net Weight    -   5kg.200gm      Gross Weight - 10kg . 500gm



















Company Details close-icon

Life Care Systems, as a company, is a market leader in Indian Healthcare industry a position that is bild of hard work, superior product performance and a commitment to customer satisfaction, and with a fifteen years experience as a part of Life Care systems is supplying the best products and services available in the field of physiotherapy.
Life Care Systems started back in 2000, has been established thanks to professionals of this field, who have gathered their own know-how with the aim of creating a product line symbol and result of years of experience in the field of manufacturing, design and sale of safe and reliable equipment Made in India.
The optimisation of our products is carried out by a highly expert staff in the research and development department of the company who work together with the management and production chiefs. In this way we are capable of coming up with the right products to meet the real requirements of our customers as well as maintaining leadership in the field of rehabilitation.
In order to reach our aim, we followed the guidelines of a “bottom-up” policy which basically means starting from customer requirements and transferring these directly that’s why LCS equipments satisfy the user’s need finaly.
The entire organisation is based on four main cardinal points:
Product quality and processes
Easy-to-use instruments
Ergonomic components
Attention paid to design and details
Another aspect we consider to be of vital importance is that of safety for the operator and this was obtained not only by fully adhering to the very strict rules which regulate such products by means of providing ISO certification.
LCS takes care of and protects physiotherapists.
LCS responds to their requirements ahead of time
LCS improves and adds value to their performance.
LCS is their ?reliable partner?
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 1998
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Electrosurgical Cautery Machine?

Quantity
Seller Contact Details
  • Seller Life Care System
  • Address Morta, Ghaziabad, Uttar Pradesh

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Electrosurgical Cautery Machine at Best Price in Ghaziabad - ID: 3797513
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Electrosurgical Cautery Machine

Listing ID #3797513

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1998

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad)

 

Bipolar diathermy is the emitance of the HFAC from the electrosurgery diathermy down one prong of a bipolar forcep through the tissue that has been placed between the forcep tips and returned to the diathermy via the second prong. Bipolar diathermy does not require a dispersive electrode (patient return pad).

 

Background
 

Surgical instrument india has three effects on body tissue:

  • cut - generation of heat destroys tissue cell
  • coagulation - tissue cells contract to increase normal clotting
  • fulguration - cell walls destroyed through dehydration

 

Each of these processes generates smoke plume which contains:

  • chemical by-products (eg toluene, acrolein, formaldehyde, benzene and hydrogen cyanide)
  • intact cells, cell parts and intact viral DNA
  • viable bacteria, including mycobaterium tuberculosis, have also been cultured

To minimize associated health hazards, specially designed smoke evacuation systems should be used where available and surgical filtration masks donned for all surgical procedures.

 

Prior to use
 

The Electrosurgery Unit (ESU) should only be use by members of the peri-operative team deemed competent.

  • The ESU should be inspected and safety features tested (eg lights, activation patient return electrode sound indicator) before each use
  • All cables and electrodes must be checked prior to use to ensure insulation is intact
  • Any problems must be reported to the Biomedical Engineering Department immediately.
  • The volume of the activation sound indicator should be maintained at an audible level

 

General use
 

The diathermy surgery should be protected from spills. Fluids should not be placed on top of the ESU
The dispersive electrode should be the appropriate size for the patient’s weight and an electrode should never be cut to size
Only those active electrodes recommended by the manufacturer should be used. If an adapter is used it should be one that is approved by the manufacturer and does not compromise the generator's safety features.
After the patient is positioned on the operating table, the dispersive electrode should be placed on a clean, dry intact skin surface over a large, well perfused muscle mass

The dispersive electrode should not be placed over.

  • a bony prominences
  • implanted metal prosthesis
  • areas distal to a tourniquets
  • scar tissue
  • hairy surfaces
  • pressure points/areas

 

The electrode should be positioned as close to the operative site as possible
The dispersive electrode should be connected to the ESU prior to draping to ensure adequate contact & then the lead disconnected from the ESU temporarily to allow for the draping of the patient and the positioning of the surgeon

 

Mono Polar/Bipolar Surgical Diathermy
AYU 250 ANL is a high frequency Electro Surgical Unit Micro controller based innovative design, together with high reliability makes AYU 250 ANL Electro Surgical Diathermy unit the most favorable choice of doctors. The technical ability of the unit is combined with patient's safety that are of prime importance both for patient and the user. The AYU 250 ANL Electro Surgical Diathermy is designed with SMPS power supply which provides particular safety and reliability. AYU 250 ANL is user friendly Electro Surgical unit.

SAFETY IN USE
The Technical conceptions of the AYU 250 ANL meet the requirements of highly refined Electro Surgical techniques all national and international safety standards are confirmed. The micro function and knob allows for an instant variation in the output power for more delicate application such as neurological or micro surgery.

 

  • Ortho Peallic

  • Dermatology

  • Otolaryngology

  • Ophthalmology

  • Ginaecology

  • Aesthetics

  • Vascular Disease



  MODE RATED LOAD (OHMS) MAXIMUM POWER(WATTS)
Monopolar
Cut
Pure
Blend
300
300
250
180
Monopolar
Coag.
Force
Soft
300
300
180
150
Bipolar
Cut
Pure
Blend
100
100
100
70
Bipolar
Coag
Force
Soft
100
100
70
50

Unit Size      -     L*W*H - 335x330x125 mm
Box Size      -     L*W*H - 430x405x280 mm
Net Weight    -   5kg.200gm      Gross Weight - 10kg . 500gm



















Company Details close-icon

Life Care Systems, as a company, is a market leader in Indian Healthcare industry a position that is bild of hard work, superior product performance and a commitment to customer satisfaction, and with a fifteen years experience as a part of Life Care systems is supplying the best products and services available in the field of physiotherapy.
Life Care Systems started back in 2000, has been established thanks to professionals of this field, who have gathered their own know-how with the aim of creating a product line symbol and result of years of experience in the field of manufacturing, design and sale of safe and reliable equipment Made in India.
The optimisation of our products is carried out by a highly expert staff in the research and development department of the company who work together with the management and production chiefs. In this way we are capable of coming up with the right products to meet the real requirements of our customers as well as maintaining leadership in the field of rehabilitation.
In order to reach our aim, we followed the guidelines of a “bottom-up” policy which basically means starting from customer requirements and transferring these directly that’s why LCS equipments satisfy the user’s need finaly.
The entire organisation is based on four main cardinal points:
Product quality and processes
Easy-to-use instruments
Ergonomic components
Attention paid to design and details
Another aspect we consider to be of vital importance is that of safety for the operator and this was obtained not only by fully adhering to the very strict rules which regulate such products by means of providing ISO certification.
LCS takes care of and protects physiotherapists.
LCS responds to their requirements ahead of time
LCS improves and adds value to their performance.
LCS is their ?reliable partner?
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 1998
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Electrosurgical Cautery Machine?

Quantity
Seller Contact Details
  • Seller Life Care System
  • Address Morta, Ghaziabad, Uttar Pradesh

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice