My ExportersIndia

For Buyer

For Seller

For Help

Agricultural Pipes

Our product range contains a wide range of UPVC Column Pipes, UPVC Plumbing Pipes, UPVC Garden Pipe and UPVC Agricultural Pipes

UPVC Column Pipes

  • Min. Order (MOQ) 10 Piece
  • Material UPVC
  • Thickness 10-20mm
  • Application Water Rising For Submersible And Jet Pump For Irrigation, Domestic, Industrial Mining, Chemical Distribution. A Good Substitute For MS, ERW, GI, HDPE, And SS Column Pipes. UPVC Is Resistant To Corrosion, Chemical Reaction, And Erosion, Making It Ideal For
  • Brand Name Govardhan
  • Packaging Type White
  • Maximum ambient temperature 70oC
  • Maximum installation depth 350 m
  • Installation Vertical, Horizontal or Inclined
  • Design Follows ASTM-D-1785 Specification. Smooth Surface Finish Reduces Hydraulic Friction. Internal & External Threading And Bell-spigot Ends Ensure Easy And Reliable Jointing. SS Pump And Pipe Adapters Provide A Corrosion-proof System.
  • Size 25 mm to 140 mm

Range :

Saffire Class Medium Class

Crystal Class Standard Class

Standard Plus Class Heavy Class

Super Heavy Class

 

SPECIFICATIONS :

  • Maximum ambient temperature : 70 C
  • Maximum installation depth : 350 m
  • Installation : vertical, horizontal or inclined

 

APPLICATIONS

  • Water rising for submersible and jet pump for irrigation, domestic, industrial mining, chemical distribution
  • A good substitute for MS, ERW, GI, HDPE and SS column pipes.
  • uPVC is nearly inert towards corrosion, chemical reaction and erosion. Hence, it is ideally suited for long term use in salty, sandy and chemically aggressive water.

 

INSTALLATION

  • Since uPVC pipes are lighter, they are easy to handle, transport and install
  • A typical installation is shown alongside.
  • Special threads along with our BI-Lock Technology ensure quicker and safer installation

 

  • USP Govardhan Column Pipes : Govardhan column pipes are manufactured with immaculate production
  • technology to ensure the tensile strength in order to withstand the robust conditions of varied borewells.

Govardhan column pipes are imbibed with following features :

Bi Lock Technology : In order to ensure that the joint between coupler and pipe to be inseparable Govardhan column pipes are doubly locked with freezing lock containing utmost quality of adhesive and then re-assured by providing a stainless steel grub screw between them.

Double Cut Rings : Govardhan pipes are fitted with high grade double cut rings which ensure the infrangible lock at the borewell sites. Double cut rings makes the task of fitter lot more easier and immaculate by providing unshakable grip between two pipes

TECHNICAL PARAMETERS

Nominal Diameter ND Class Ultimate breaking load (kgf) Safe load pulling capacity (kgf) Safe hydro static pressure (kg/cm²) Safe total pump delivery head (mtr.)
ND : 25 mm (1 inch) OD : 33 mm Medium 890 600 15 150
  Crystal 1150 750 21 210
  Standard 1800 1100 30 300
ND : 32 mm (1.25 inch) OD : 42 mm Medium 1380 900 15 150
  Crystal 1800 1050 21 210
  Standard 2500 1500 25 250
  Standard Plus 2700 1700 27 270
  Heavy 3100 1850 35 350
  Super Heavy 3200 1900 40 400
ND : 40 mm (1.50 inch) OD : 48 mm Medium 1470 1200 15 150
  Crystal 2500 1500 21 210
  Standard 2750 1750 25 250
  Standard Plus 3350 2050 27 270
  Heavy 4050 2350 35 350
  Super Heavy 4150 2400 40 400
ND : 50 mm (2.00 inch) OD : 60 mm Medium 1700 1250 12 120
  Crystal 3150 1650 17 170
  Standard 3600 1950 20 200
  Standard Plus 4000 2150 24 240
  Heavy 4700 2750 27 270
  Super Heavy 5750 3350 35 350
ND : 65 mm (2.50 inch) OD : 75 mm Medium 3150 1400 12 120
  Crystal 4050 1600 15 150
  Standard 4750 2350 17 170
  Standard Plus 5750 3250 21 210
  Heavy 7100 4200 26 260
  Super Heavy 8850 5200 35 350
ND : 80 mm (3.00 inch) OD : 88 mm Sapphire 4250 2700 10 100
  Medium 4450 3000 12 120
  Crystal 5250 3250 15 150
  Standard 6850 4000 17 170
  Standard Plus 8050 4810 21 210
  Heavy 9500 5510 27 270
  Super Heavy 11800 7250 35 350
ND : 100 mm (4.00 inch) OD : 113 mm Sapphire 7000 3000 10 100
  Medium 7850 3300 12 120
  Crystal 8100 4000 15 150
  Standard 10800 5550 16 160
  Standard Plus 12500 7650 21 210
  Heavy 15800 9100 26 260
  Super Heavy 18700 12500 35 350
View Complete Details

UPVC Plumbing Pipes

  • Min. Order (MOQ) 50 Meter
  • Country of Origin India
  • Feature Excellent Quality, Crack Proof
  • Application Plumbing
  • Thickness 0-10mm
  • Material UPVC
  • Brand Name Govardhan
  • Size 15 mm to 100 mm
  • Range SCH-40 / SCH-80 / SCH-120

Specifications :

  •  Suitable upto temperature 60 C (continuously) and 90 C (for short time).
  • Size : 15 mm (0.50 inch) to 100 mm (4.00 inch)
  • Available in SCH-40, SCH-80 and SCH-120
  • Specifications followed : ASTM-D-1785
  • Colours Available : White & Blue

 

Application :

Building constructions :

These pipes are suitable for water connections to bathroom, kitchens, washbasins and laboratories.

Portable water supply :

It can be used for commercial complexes, individuals homes, flats, offices, hotels, hospitals and transport terminals.

Industrial Applications :

Distribution of milks, fluids and gases in dairy plants, industrial estates, agriculture,  telecommunications and irrigation project etc.

 

Installations

Use of teflon tap recommended to avoid damage and subsequent leakage. Can also be jointed to metal pipes and fittings. No specia equipment required. Lesser time consuming than metal pipes.

 

Benefits :

  • Light weight, easy to handle and transport.
  •  Inert to acids, alkalis, oils and fats.
  •  Smoother inside & outside surface
  • Maintenance free
  • Most economically in installation
  • No Surface corrosion.
  •  Tough and strong
  •  Low frictional losses
  •  Wear and abrasion resistance
  •  Good thermal & electrical insulation

 

 

Technical Parameters


Download Detail File : Click Here
View Complete Details

UPVC Garden Pipe

  • Min. Order (MOQ) 50 Meter
  • Size 0.5 Inches To 1.25 Inches
  • Country of Origin India
  • Application Farm Irrigation, Domestic, Agriculture, Gardening, Irrigation
  • Shape Round
  • Material PVC
  • Brand Name Govardhan
  • Packaging Type Yellow
  • Surface Treatment Polished
  • Pressure Medium Pressure, Low Pressure, High Pressure
  • Range 15 Mtr., 30 Mtr. , 50 Mtr.

PVC (Polyvinyl Chloride) garden pipes are widely used for gardening and landscaping purposes. Here's an overview of PVC garden pipes, which might be relevant to your query:

PVC garden pipes are made from polyvinyl chloride, offering high durability and resistance to weather conditions. They are crack-proof and leak-proof, ensuring long- lasting performance.

Flexibility: These pipes are flexible, making them easy to handle and maneuver around garden spaces. They do not twist or tangle easily, which simplifies their use.

Eco-Friendliness: Many PVC garden pipes are manufactured without harmful chemicals, such as phthalates, and are non-carcinogenic. They are also UV stabilized to prevent degradation from sunligh 

Variety in Sizes and Colors: PVC garden pipes come in various sizes (e.g., 1/2 inch, 3/4 inch, 1 inch & 1.5 inches) and colors (e.g., yellow, blue, transparent), catering to different needs and preferences.

Applications: Besides gardening, these pipes are used for cleaning vehicles, equipment, and industrial purposes. They are versatile and can be applied in various settings.

 

Installation of PVC Garden Pipes

  • For setting up a PVC garden irrigation system, follow these steps:

Plan Your Garden Layout: Determine where you want to place your irrigation lines based on plant types and water requirements

Calculate PVC Pipe Lengths: Measure distances between the water source and irrigation points

Cut PVC Pipes: Use a hacksaw or PVC pipe cutter to cut pipes to the required lengths

Assemble the System: Use PVC fittings (tees, elbows, couplings) and cement to assemble the main water supply line and irrigation lines

Install Irrigation Emitters: Choose emitters like drip irrigation or soaker hoses based on your 5 watering needs.

Secure the Pipes: Use ground stakes or pipe straps to keep the pipes in place.

Test the System: Check for leaks and ensure proper water distribution.

View Complete Details

UPVC Agricultural Pipes

  • Size 20 mm to 315 mm
  • Brand Name Govardhan
  • The thumb rule principle is 1 kgf/cm=10 m of water column
  • Range 2.5 kgf/cm2, 4 kgf/cm2, 6 kgf/cm2, 10 kgf/cm2
  • Thermal conductivity 4X 10-4Cal/ hr. cm2/0c/cm
  • Co-efficient of linear expansion 5.4x10-5mm/m/0c
  • Specific Gravity 1.41—1.46gm/cm2
  • Impact strength Complies with IS : 49852000
  • Modulus of elasticity 3.0-3.8x104kgf/cm2
  • Electrical Resistance 1014 ohm-cm
  • Vicat Softening Point 80oc
  • Tensile strength 500-550kg/cm2
  • Williams and Hazen Constant 150 Remain Constant

Properties :

  • Co-efficient of linear expansion : 5.4 x 10 mm/m/ C
  • Specific gravity : 1.41-1.46 gm/cm
  • Impact Strength : Complies with IS : 4985 2000
  • Electrical Resistance : 10 ohm-cm
  • Vicat softening point : 80 C
  • Tensile Strength : 500-550 kg/cm

Applications

  • Industrial ducting
  • Building Installations
  • Sewerage & drainage
  • Gas & Oil supply lines
  • For slurry disposal lines
  • Air conditioning ducting
  • Rural & urban water supply
  • Agriculture & Irrigation System
  • Sewerage & industrial effluent disposal
  • Power and telecommunication cable ducting
  • Discharge pipes for hospitals & residential buildings
  • Portable water supplies and drinking water supplies
  • Plumbing and drainage systems in the dwelling
  • houses
  •  Lift Irrigation, Bore wells etc. by both Govt. & Farmers

 

Installation

While designing the pipe line system, the level and depth of the trench is calculated depending on factor such as the terrain and function of the pipeline. Excavation and pipe laying must take place simultaneously, as leaving trenches open for too long, makes them unsuitable for use. A fine layer of sand should be spread on the trench-bed, to avoid mechanical damage arising due to the pipe coming in direct contact with the solid bed. Like wise, it is also recommended to put a fine layer of fine sand on the top of the pipe before filling and carrying the soil to cover the trench. As pipe laying advances, trenches must be backfilled immediately. The pipe joints however should be left exposed till after the pipe line s stem has been tested. The maximum width of the trench must be equal to the pipe diameter plus 300 mm. At the crown of the pipe, the trench width must not exceed the pipe diameter plus 600 mm.

 

.


Download Detail File : Click Here

Design

1. Basic Parameters
1.1 Water Quantity (Q) : the amount of water required to irrigate the land, considering crop pattern and irrigation frequency (in liters/second)
1.2 Length of Pipe line (L) : The length of the pipe, from source to destination of discharge point (in meters)
1.3 Static Head (H) : The level difference between the lowest and the highest level of the pipe (in meters)




Selection Of Pipe

For best efficiency and optimum output, use the flow chart available below shown. It is suggested that one should select the pipe size at an inter section of velocity 1 meter/second and discharge (litre/second). Frictional losses (h2) are also to be taken care of as shown in the diagram.

.


Download Detail File : Click Here

Frictional Losses Can Also Be Calculated By Empirical Hazen Williams Formula I.e :

V = 4.567 X 10 X C X D X S
Where V = Velocity of fluid flowing through the pipe
D = Internal Diameter of the pipe
C = Hazen Williams co-eff. for PVC (150)
S = Hydraulic Gradient





Guideline For Pressure Class Selection

The total head (H) acting on the pipe area on a particular point is calculated as
H = h1+h2 + 10% (h1+h2) (in meter/km.)
Where 10% (h1+h2) is the safety factor for losses in valves and fittings
The selection of high pressure class can then be done from
the table :






Download Detail File : Click Here

Selection Of Pump

The formula is : HP of the pump = Q X H/75 X h
Where s = Efficiency of the pump in % (i.e. 65%)
From the basis of these calculations suitable pump can be procured from the market.



Selection And Installation Of The Air Valves

An air valve in the pipe line, functions the way are nose does. This is one of most critical - yet often neglected components in an uPVC Pipe line.

Since air is compressible in nature, it tends to accumulate in the pipe line. A non-functional air valve causes the accumulated air to generate very high localized pressure. This can not be read on a conventional pressure gauge. To avoid such an occurence, air valve should be installed at distances of 300 to 400 meters at all peak points through out the pipe line.

Such air valves can be easily procured from the market by having a proper selection of material
available.


D I M E N S I O N A S P E R I S 4 9 8 5 : 2 0 0 0


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us