My ExportersIndia

For Buyer

For Seller

For Help

Chillers

Our offered Product range includes Air Cooled Chiller and Water Cooled Chiller.

Air Cooled Chiller

80,000 - 1.50 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Condition New
  • Category Cooling & Heating
  • Temperature 7 to 35oC
  • MOQ As per Client Requirement

Air Cooled Chiller can cool the water temperature ranging from 7 to 35oC. The low cooling temperature can be customized as per customer's needs. The micro computer controls the system running and the temperature can be precise to 1oC.  The water tank is made from the stainless steel and has a heat insulation layer. Freezing pipelines have the insulation layer to improve refrigerating efficiency. Low speed and noise blower fan. The blower fan stops along with the compressor, thus effective electric energy saving.The overload protection device is used for compressor and pump to prolong the service life. The multi protection device (antifreezing protection, high and low pressure protection and flow protection) ensures the system safety.

Graph


Download Detail File : Click Here

Technical Specifications

 Model   SL-3A SL-5A SL-10A SL-15A SL-20A SL-30A SL-40A SL-50A SL-60A
Refrigeration capacity Kw 10 15 30 45 60 90 120 150 180
Kcal/h 7740 12900 25800 38700 51600 77400 103200 129000 154800

Compressor  Inputpower
Kw 2.2 3.7 7.5 11 15 22.5 30 37.5 45
HP 3 5 10 15 20 30 40 50 60
Type
Refrigerant
/Filling quantity
R22
Kg 1.5 2.5 5 7.5 10 12 18 30 35

Water tank capacity
L 60 90 180 270 360 --- --- --- ---
Evaporator type  Serpentine pipe type        Shell type
Freezing water pipe Inch 1 1 1.5 2 2 3 3 4 4
 
Freezing water flow rate
L/min 60 90 180 270 270 270 380 460 550
M3/h 3.6 5.4 11 16 16 16 23 28 33
/Type
Fan motor   /Power
 Axial flow type blower fan
Kw 0.45 0.45 0.45x2 0.65x2 0.65x2 0.65x4 0.65x4 1.1x2 1.8x4
Safeguard
Protection of high & low pressure,          Protection of high & low pressure,compressor overload,
Compressor overload,pump overload               pump overload,antifreezing,flow rate
Power AC3+N+PE50/60Hz
Dimensions(mm) L 750 1100 1450 2200 2200 2200 2500 2200 3000
W 680 680 790 1000 1320 1320 1200 2000 2200
H 900 1100 1120 2100 2100 2180 2290 2180 2180
Weight Kg 100 160 300 700 750 1400 1600 2200 2400

 

Note:

  • The working conditions for refrigeation:
  • Freezing water inlet temperature is 12oC,and the outlet temperature is 7oC
  • Air side inlet (envirnmental temperature) is 35oC  








View Complete Details

Water Cooled Chiller

80,000 - 1 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Type Water Chiller
  • Condition New
  • Category Cooling & Heating
  • MOQ As per Client Requirement

Water Cooled Chiller can cool the water temperature ranging from 7 to 35oC. The low cooling temperature can be customized as per customer's needs. The multi protection device (antifreezing protection, high and low pressure protection and flow protection) ensures the system safety. The water tank is made from the stainless steel and has a heat insulation layer. Freezing pipelines have the insulation layer to improve refrigerating efficiency.The micro computer controls the system running and the temperature can be precise to 1oC. The overload protection device is used for compressor and pump to prolong the service life.

Graph


Download Detail File : Click Here

Technical Specifications

 Model   5W 10W 15W 20W 30W 40W 50W 60WL 70WL 80WL 90WL 100WL 120WL

Refrigeration capacity
Kw 15 30 45 60 90 120 150 180 210 240 270 300 360
Kcal/h 12900 25800 38700 51600 77400 103200 129000 154800 180600 206400 232200 258000 309600
Compressor Inputpower Kw 3.7 7.5 11 15 22.5 30 37.5 45 52.5 60 67.5 75 90
HP 5 10 15 20 30 40 50 60 70 80 90 100 120
Type
Refrigerant 
/Filling quantity
R22
Kg 2.5 5 7.5 10 15 20 25 30 35 40 45 50 60
Water tank capacity L 90 180 270 360 360 --- --- --- --- --- --- --- V
Evaporator type  Serpentine pipe type          Shell type
Freezing water pipe Inch 0.5 1.5 2.0 2.5 3 3 4 4 4 4 4 4 4
Freezing water 
flow rate
L/min 90 180 270 270 270 380 460 550 630 730 920 1030 1200
M3/h 5.4 11 16 16 16 23 28 33 38 44 55 62 72
Condenser Type  Shell type
Cooling wwater pipe Inch 1 1.5 2 2.5 3 3 4 4 4 4 4 4 4
Cooling water flow rate L/min 110 210 350 350 350 480 610 710 830 950 1160 1330 1500
M3/h 7 13 21 21 21 29 37 43 50 57 70 80 90
Safeguard    Protection of high & low pressure,                        Protection of high & low pressure,compressor overload,
   Compressor overload,pump overload                            pump overload,antifreezing,flow rate
Power AC3+N+PE50/60Hz
 
Dimensions(mm)
L 840 1550 1660 1800 1950 2180 2190 2260 2870 2870 3000 3020 3020
W 670 710 820 950 1000 1200 1200 1200 1200 1300 1300 1300 1300
H 980 1150 1400 1700 1330 1420 1450 1590 1660 1660 1890 1910 1910
Weight Kg 160 300 460 600 900 1120 1190 1430 1560 1590 2110 2230 2350

 

Note:

  • The working conditions for refrigeation:
  • Freezing water inlet temperature is 12oC,and the outlet temperature is 7oC
  • Air side inlet (envirnmental temperature) is 35oC  