Our Products
We offer a complete product range of Lifedop 150 Vascular Doppler Lifedop 150 with 8 Mhz Probe, Arabin Cervical Pessary- Preterm Birth Prevention ARABIN Cerclage Pessary perforated, Digital Video Colposcope, cautery silencer cryo gun cryo surgical system and Hysteroscopic Pump
L150R Diabetic Foot Care Vascular Doppler for ABI
| Model Name/Number | L150R |
| Machine Condition | New |
| Type | Portable |
| Frequency | 8 MHz |
| Number Of Transducer Sockets | 1 |
| Clinical Application | Vascular Screening |
| Warranty | 1 Year |
| Is It Portable | Portable |
| Brand | Diapodo Care |
| Frequency Range | 8Mhz |
| Equipment Type | Doppler Machine |
| Battery Backup | Yes |
| Weight | 280 gms |
| Packaging Type | Box |
| Usage | For Diagnose For Peripheral Arterial Disease |
Vascular studies are a non-invasive procedure used to assess the blood flow in arteries and veins. A transducer sends generates ultrasonic sound waves at a frequency too high to heard (8MHz). When the transducer is placed over the skin at specific locations and angles over the arteries the ultrasonic waves moves through the skin and other body tissues to the blood vessels, where the waves echo off of the blood cells. The transducer picks up the reflected waves and sends them to main unit, which makes the ultrasonic sound waves audible.
Doppler ultrasound : This doppler techinque is used to measure and assess the flow of blood vessels. The amount of blood pumped with each beat is an indication of the size of a vessel 's opeining. Also doppler can detect abnormal blood flow within a vessel, which can indicate a blockage caused by a blood clot, a plaque , or inflammation.
Hand held Doppler model L150R, is a non-invasive vascular test used to screening with diabetes patients. L150R helps to diagnose the peripheral arterial disease (PAD) or Calcification. A complete self contained system to carry out Vascular and arterial investigation and monitoring, using the principle of doppler ultrasound. Using the ABI Manager software/Android application provided along with the system user can generate patient report that gives automatic interpretation based on TASCII guidelines.
Additional Information:
Payment Terms : T/T, Western Union
Delivery Time : 2-3days
The Arabin pessary isa silicone ring-shaped device that is inserted around the cervix to prevent preterm birth.It's designed to support the cervix, keep it closed, and incline it towards the sacrum.The Arabin pessary is considered a non-invasive alternative to surgical cerclage, which can have complications
Description
The cerclage pessary consists of high-quality silicone. It can be stored at temperatures from 0 to 50 C protected from UV radiation without contact to reactive media, gas, ozone or mineral oil.
Since the introduction of the device the material and the consistency of the product have been improved. Since 202, objective compression values were adapted according to the to the indication (Model 3).
Application/Intended Purpose
The Cerclage pessary can stay in the virgina more than 30 days (Class IIb). The pessary consists of flexible comfortable silicone. Like all silicone pessaries it is elastic, can be folded and thus be inserted without side effects (pain). The cervical pessary is designed to support the lower uterine segment and the shape of the cervix. The risk of threatining preterm birth is nowadays detected by transviginal sonogrophy. A Cerclage pessary is only indicated in patients with (early or late) changes such as cervical shortening and/or an inner opening of the internal os (funneling). In cases with increased risk by either history (prevoius preterm birth, cervical operations such as cone biopsy) or multiple pregnancy an early transviginal sonography is indicated and should be repeated. If the transvaginal sonogrophy is performed as part of a screening procedure the same cervical changes such as cervical shortening and funneling can occur. The cerclage pessary is indicated for both risk and screening patients.
The treatment can be initiated from 12 gestational weeks onwards (in rare cases with pre-existing short cervix). The pessary is not intended to close the cervix but to rotate it towards the sacrum. Hereby, the uterocervical angle between the lower uterine segment and the cervix becomes significantly more acute as compared to the values before placement. In some patients, even funneling and cervival length may restore. In mild forms of genital prolapse (mainly in multiple pregnancy or multi-parous women) the subjective symptoms of pressure may become less after placement.An increased vaginal discharge is a common side effect, whereby the perforations inside the pessary allow a better drainage. Nevertheless, vaginal discharge should not be confused with a so called infection and should not be routinely treated with antibiotics. It could be demonstrated that increased discharge is not associated with a change of the vaginal microbiome. Before insertion, bacterial swabs can be performed to exclude bacterial colonization (no absolute indication). In patients with U-shaped funnelling a wider upper diameter (35 mm) might prevent unnecessary prostaglandin release.
Note
The product is for single use only and must not be used in other patients.
Additional Information:
Payment Terms : T/T, Western Union
Packaging Details : To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided
Delivery Time : 2-3 days
A digital colposcope isa medical diagnostic instrument used to provide a magnified, illuminated view of the cervix, vagina, and vulva. It captures, displays, and stores digital images and videos, allowing for more detailed analysis than traditional optical colposcopes.
Additional Information:
Packaging Details : To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Delivery Time : 3-4 days
Applications(Gynaecology):
Applications(Protocology):
Applications(Otorhinolaryngology):
CRYO 004 / CRYO 004 B ON-OFF super deluxe enables us to cut off the gas line (flow) without closing the cylinder while we interchange the probe.Cleaning the inner hypodermic needle will be much easier , thus saving valuable time. CO2 gas can be used in the equipment very conveniently , since removal of any clog will be very simple.Cryosurgery of hemorrhoids may be combined with ligation. This procedure has proved to be effective for large hemorriods because ligation cuts off the heat input by the blood supply and makes freezing more effective(lethal).
Additional Information:
Delivery Time : 2-3days
Hysteromat PumpEasy to read four display and warning tonesAutomatically detects the instruments being used and provides accurate measurementsSuitable for diagnostic & operative hysteroscopy as well as laparoscopy proceduresSafety first with auto cut facilityPowerful roller pumpFully microprocessor controlled
Additional Information:
Payment Terms : T/T, Western Union,
Packaging Details : To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Delivery Time : 3-4 days
intrauterine device (IUD
Mirena is a brand name for a levonorgestrel intrauterine device (IUD) thatprevents pregnancy and treats heavy menstrual bleeding.It's a T-shaped plastic frame that releases the hormone levonorgestrel slowly into the uterus.Mirena works by:Thinning the uterine lining, Thickening cervical mucus, Preventing sperm from moving and surviving in the uterus, and Preventing ovulation in some women
Additional Information:
Payment Terms : T/T, Western Union
Packaging Details : To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided
Pap smears area lifesaving screening tool for cervical cancer. The test can detect abnormal cells in the cervix before they become cancerous. Healthcare providers often perform HPV tests during Pap tests to check for HPV, one of the leading causes of cervical cancer.
Specification/Additional DetailsAdditional Information:
Payment Terms : T/T, Western Union
Packaging Details : To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Delivery Time : 2-3 days
A hysteroscopic irrigation pump isa specialized medical device used to deliver a controlled flow of fluid into the uterus during hysteroscopy procedures to distend the cavity and maintain a clear visual field
A hysteroscopy pump is a medical device crucial fordistending the uterus with controlled fluid (like saline), providing surgeons aclear, magnified viewinside the uterine cavity for diagnosis and treatment of issues like fibroids, polyps, or abnormal bleeding, ensuring safety by managing fluid pressure and flow, and even monitoring for fluid absorption to prevent complications
Additional Information:
Payment Terms : T/T, Western Union
Delivery Time : 2-3days