Our Product / Services
Our offered Product range includes Static Pass Box, Air Shower, Laminar Air Flow, BIOSAFETY CABINET CLASS and Pass Box Dynamic.
| Model No. | PB-1 | PB-2 | PB-3 |
| Dimension (mm) | 450 x 450 x 450 | 600 x 600 x 600 | 600 x 600 x 900 |
| Florescent Light | 8/20 W with milky diffused | ||
| U. V. Light | 8/15 W | ||
| Lock | 12 volt, electromagnet for door interlocking | ||
| Buzzer | 12 volt | ||
| Indicator | 12 volt | ||
| Three Pin Top | 16 amp with connection cable | ||
| Door | Sandwitched door with double side view panel | ||
| Electric Supply | AC 230V, 50/60Hz | ||
| Hour Meter Totalizer | For U. V. Light |
| Door Handle | Can be fitted on both sides |
| HEPA Filter | Can be supplied with HEPA filters |
| Model No | HLF-1 | HLF-2 | HLF-3 | HLF-4 |
| Working Table Size | 2' x 2' | 3' x 2' | 4' x 2' | 6' x 2' |
| Working Size | 2' x 2' x 2' | 3' x 2' x 2' | 4' x 2' x 2' | 6' x 2' x 2' |
| HEPA Filter Size | 2' x 2' x 6” | 3' x 2' x 6 | 4' x 2' x 6” | 3' x 2' x 6” |
| No. of Motor/Blower | 1 | 1 | 1 | 2 |
| Illumination | 1 x 20 w | 1 x 20 w | 2 x 40 w | 2 x 40 w |
| Main Filter | HEPA Filter (99.97% efficient at 0.3 micron particles) | |||
| Pre-Filter | High efficiency pre-filter (Washable) | |||
| Sterilization | By U.V. Germicidal Tube in work area | |||
| Front Door | Made of Plexi Glass 6 mm | |||
| Noise Level | Less than 65 db | |||
| Standard Accessory | Gas/Air cock | |||
| Electric Supply | AC 230V , 50/60Hz | |||
| Spare HEPA Filters | Can be provided at an extra cost |
| Magnetic Gauge | (To track filter pressure) in lieu of static pressure manometer. |
| Interlocking | U.V . Germicidal tube & fluorescent light with auto switch off/on mode for motor blower when the door is closed/open. |
| Hour Meter totalizer | For U.V . light |
| Microprocessor LCD Controller with Auto Switch off mode | For motor blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of sterilizing time of the chamber and the switches off U.V . germicidal tube and automatically switches ON the fluorescent light, alerting the user that the bench is ready for use |
| Can be fitted with micro chip controlled electronic digital indicator | T o display air flow rate fitted with sensor |
| Model No | BSC-1 | BSC-2 | BSC-3 | BSC-4 |
| Working Table Size | 2' x 2' | 3' x 2' | 4' x 2' | 6' x 2' |
| Working Size | 2' x 2' x 2' | 3' x 2' x 2' | 4' x 2' x 2' | 6' x 2' x 2' |
| HEPA Filter Size | 2' x 2' x 6" | 3' x 2' x 6" | 4' x 2' x 6" | 3' x 2' x 6" |
| No. of Motor/Blower | 1 | 1 | 1 | 1 |
| Illumination | 1 x 40 w | 1 x 40 w | 2 x 40 w | 2 x 40 w |
| Cabinet Materiel | Wooden or Cold Rolled Steel Powder Coated or Stainless Steel (SS-304) | |||
| Work Table | Stainless Steel (SS-304 grade) | |||
| View Window | In work chamber to monitor the samples | |||
| Main Filter | HEPA Filter (99.97% efficient at 0.3 micron particles) | |||
| Pre-Filter | High efficiency pre-filter (Washable) | |||
| Sterlization | By U. V. Germicidal Tube in work area | |||
| Manometer | Static pressure analogue type. | |||
| Sliding Sash | Counter balanced door for effortless operation | |||
| Noise Level | Less than 65 db | |||
| Standard Accessory | Gas/Air cock and Multipoint 15/5 Amp. electric socket | |||
| Electric Supply | AC 230V, 50/60Hz | |||
| Static Pressure Manometer | Can be provided at an extra cost |
| Exhaust Ducting | Per running feet cost will be charged extra |
| HEPA Filtration at exhaust | Can be done at an extra cost |
| Virus burn out at Exhaust | Can be done at an extra cost |
| Magnehelic pressure differential gauge | To track filter pressure in lieu of static pressure manometer (Can be provided at an extra cost) |
| Interlocking of U.V . germicidal tube & fluorescent light | with auto switch off/on mode for motor blower when the door is closed/open |
| Hour meter totalizer for U.V . light | Can be done at an extra cost |
| Glove Ports and Gauntlets | Can be done at an extra cos |
| Fumigation Tray – for effective disinfection/ decontamination | Can be done at an extra cost |
| Electronic filter choke alarm (Differential pressure monitor). | Can be done at an extra cost |
| Microprocessor LCD controller | With auto switch off mode for motor blower when door is closed. |
| Digital buzzer timer | Sounds an audio alarm on completion of sterilizing time of the chamber |
Pass Box Dynamic (PLT-273 A)