Taber Stiffness Tester

Listing ID #4158000

  • Supply Type Manufacturer, Supplier
Preferred Buyer From : All over the world

The TABER® V-5 Stiffness Tester - Model 150-B or 150-E is used to evaluate stiffness and resiliency properties of materials up to 10,000 Taber Stiffness Units.  This precision instrument provides....
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Exporter
  • Year of Establishment 2004

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The TABER® V-5 Stiffness Tester - Model 150-B or 150-E is used to evaluate stiffness and resiliency properties of materials up to 10,000 Taber Stiffness Units.  This precision instrument provides accurate test measurement to ±1.0% for specimens 0.004" to 0.219" thickness.  Materials include paper products, cardboard, plastics, metals, textiles, rubber, wire, tubing, felts and other sheet materials.
 
Description
Incorporated in the TABER V-5 Stiffness Tester is a bi-directional pendulum weighing system.  Providing an accurate and responsive method for measuring small load increments, this system is a critical component for determining material stiffness or resiliency.  Nine (9) distinct ranges permit testing of materials that are extremely lightweight and flexible (such as cellophane or thin metallic foils) to items that are very rigid (such as plastics).
For test ranges 2 - 9, specimens are mounted on the Taber V-5 Stiffness Tester using a clamping system.  Located on the pendulum, the lower faces of the specimen clamp jaws are exactly on the center of rotation.  This ensures a constant test length and deflection angle for accurate and repeatable results. Both jaws of the specimen clamp are adjustable, so the test specimen can be positioned precisely in the center regardless of material thickness. Force is applied to the lower end of the specimen by a pair of rollers. The rollers, which are attached to a driving disc located directly behind the pendulum, push against the test specimen and deflect it from its vertical position.  The pendulum applies increasing torque to the specimen as it deflects further from its original position.  The test point reading occurs when the pendulum mark aligns with the appropriate driving disc mark (7 1/2° or 15°), which points to the stiffness reading on the dial point.  The final reading will depend on the range in which the test is being conducted and what scaling factor to use.  The instrument outputs the moment load applied to the test specimen in TABER Stiffness Units (g · cm).
Note: The right hand roller includes a ratchet stop mechanism that greatly reduces the potential for inter-operator error caused by over or under-tightening.  The travel on the right hand assembly automatically stops when the roller contacts the specimen.
To allow the testing of materials with different stiffness properties, range weights can be applied to the pendulum.  For extremely light weight materials, a compensator range weight is mounted to the top of the pendulum.  Range weights of 500, 1000 and 2000 "Taber Units" are mounted to the bottom of the pendulum and required for stiffer materials.  An optional range weight set of 3000 and 5000 Taber units is required for test ranges 7, 8 and 9.
Range 1 is used with Taber's optional Sensitivity Range Attachment (also referred to as SR or High Sensitivity Attachment) to test extremely lightweight and flexible materials whose Taber Stiffness Unit value are between 0 - 1.  Examples include cellophane, natural fibres and synthetic filaments, tissue paper, metallic foils, films, etc.  The attachment includes two parts, the Driven Pins Holder which is secured between the clamp jaws, and the Driving Pins Holder which is mounted to the studs in place of the left and right hand rollers.  Both parts include precision pins that are oriented horizontal to the face of the V-5 Stiffness Tester. A specimen 1 1/2" x 1 1/2" is mounted such that the second and fourth pins are above the specimen.  As the driving disc rotates, the fourth pin of the Driving  Pins Holder pushes down on the specimen while the first pin pushes up.  As the sample is deflected, the Driven Pins Holder aligns the pendulum to the appropriate stiffness value.  For Range 1, the specimen is only deflected to the right.
Many customers have also utilized the Taber V-5 Stiffness Tester to evaluate wire and cable stiffness characteristics. The tester now incorporates a "v-notch" in the clamps to accommodate this testing. Suggested samples are 70mm long and 3mm - 8mm in diameter, and centered in the notch with care so as to not pinch or crimp the sample. For wire and cable samples less than 3mm diameter, it is recommended to secure the sample at a location in the flat region of the clamp.  Samples with curvature may interfere with proper set-up and function of the Stiffness tester and should be avoided. In addition, test results obtained should be used for comparison only - that is, between lots, between materials, etc.
 
The following chart is used as a guide when setting up the instrument to determine which test range to use for the type of material being tested.


Range Stiffness Units Sample Length Roller Position Sample Size Range Weight Angle of Deflection Scaling Multiplier
 
1 0 - 1 2cm SR Attachment 1.5" x 1.5" 10 Unit Compensator 15° 0.01
2 0 - 10 1cm Up 1.5" x 1.5  10 Unit Compensator 15° 0.1
3 10 - 100 5cm Down 1.5" x 2.75"  - - - 15° 1
4 50 - 500 5cm Down 1.5" x 2.75"  500 Unit 15° 5
5 100 - 1000 5cm Down 1.5" x 2.75"  1000 Unit 15° 10
6 200 - 2000 5cm Down 1.5" x 2.75"  2000 Unit 15° 20
7 300 - 3000 5cm Down 1.5" x 2.75"  3000 Unit* 15° 30
8 500 - 5000 5cm Down 1.5" x 2.75"  5000 Unit* 15° 50
9 1000 - 10000 5cm Down 1.5" x 2.75"  5000 Unit* 7 1/2° 100

Company Details close-icon

at polytech, we follow our simple road map hire the best technical staff and field engineers, have an honest and positive approach and provide the best value for money to our customers in forms of instruments and services. this coupled with the simple tried and tested formula of timely delivery as well as effective and prompt after sales service is our mantra for success.
with the purpose of providing cost effective solutions for scientific instruments as well as laboratory testing instruments backed by industry-leading warranties, our product engineers start with a clear, concise vision laying out your objectives and expectations as well as the resources required to successfully delivering your product. while working on each plan, we communicate frequently with you to keep you updated on the process as well as interact with you to ensure that the product meets your specifications and timely deliveries.
to maintain a steadfast focus on qualitative improvements that drives and empowers our presence is the rationalized business policy at polytech. we not only aim and strive to deliver impeccable service - results that are simply faultless - but to collaborate with our customers as their partners in growth and envision our success in their achievements.
  • Nature of Business Manufacturer / Exporter / Supplier / Trader
  • Number of Employees Below 20
  • Year of Establishment 2004
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Taber Stiffness Tester?

Quantity
Seller Contact Details
  • Seller Polytech Instruments Pvt.Ltd.
  • Address Ghodbunder Road, Thane, Maharashtra

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice