Our Products
We are leaders in the market for providing best range of Vibration Testing System and Bump Testing Machine
We are one of the ambitious manufacturers, exporters and suppliers of the Vibration Testing System based in Roorkey, Uttarakhand. The systems that we offer are used to in various testing applications in many industries such as automotive, defence, aerospace, nuclear and much more. The offered systems are compliant with all test standards such as MIL, IEC, ISO, BIS and more. They offer excellent stability and signal integrity. Please contact us for full information of software upgrades, add-on functions and hardware configuration of this system.
Details :
Vibration Test System 50-200 Kgf
| Technical Specification | Model | ||
|---|---|---|---|
| PE060 | PE140 | PE140 | |
| Sine Force KgF (lbf) | 50 (110) | 100 (220) | 200 (440) |
| Random Force KgF (lbf) | 35 (77) | 70 (154) | 140 (308) |
| Shock Force KgF (lbf) | - | 200 (440) | 400 (880) |
| Armature Diameter mm (in) | 60 (2.4) | 140 (5.5) | 140 (5.5) |
| Peak Acceleration g (m/sec2) | 45 (441) | 50 (490) | 60 (588) |
| Peak Velocity m/sec (in/sec) | 1 (39.3) | 1.4 (55) | 1.4 (55) |
| Pk-Pk Displacement mm (in) | 15 (0.6) | 25.4 (1) | 25.4 (1) |
| Armature Resonance Hz (±5%) | 4500 | 3500 | 3500 |
| Useful Frequency Range Hz | DC-5000 | DC-4200 | DC-4200 |
| Max. Static Payload Capacity kg (lb) | 5 (11) | 20(44) | 20 (44) |
| Trunnion Mounting | - | Provided | Provided |
| Power Amplifier Specifications | PEALK | PEA1K | PEA1K |
| Armature Power Supply | 35V/ 20A | 60V/25A | 60V/25A |
| Field Power Supply | Built-in | Built-in | Built-in |
| Input Impedance | 10 kΩ | Built-in | Built-in |
| Input Sensitivity | 4 Vrms | 4 Vrms | 4 Vrms |
| Signal to Noise Ratio (SNR) | >80dB | >80dB | >80dB |
| Total Harmonic Distortion on resistive load | 0.5%, typical | 0.5%, typical | 0.5%, typical |
| Sine Oscillator (1–5000 Hz) | Built-in | Built-in | Built-in |
| Modulation Range | DC-10 KHz | DC-10 KHz | DC-10 KHz |
| Coupling (to shaker) | Direct | Direct | Direct |
| Output Efficiency (%) | >90 | >90 | >90 |
| Structure | Desktop, rack mounted | Modular, rack mounted | Modular, rack mounted |
| Safety Interlocks | Mains Over/under Voltage, Temperature PA, Temperature Shaker, Over Travel, Cooling Interlock, Phase Fail, Field Fail, Over Load, Auxiliary | ||
| Above specifications are standard specifications, subject to revision due to continuous improvement/ developmental activities without notice. However, | |||
| the specifications quoted by us in a proposal always supersede the printed/ published specifications. | |||
| Customized testing solutions and specifications are provided on demand. | |||
Vibration Test System 400-1500 Kgf
| Technical Specification | Model | |||
|---|---|---|---|---|
| PE180 | PE180 | PE240 | ||
| Sine Force KgF (lbf) | 400 (880) | 600 (1320) | 1000 (2200) | |
| Random Force KgF (lbf) | 280 (616) | 420 (924) | 1000 (2200) | |
| Shock Force KgF (lbf) | 800 (1760) | 1200 (2640) | 2000 (4400) | |
| Armature Diameter mm (in) | 180 (7.1) | 180 (7.1) | 240 (9.5) | |
| Peak Acceleration g (m/sec2) | 50 (490) | 75 (735) | 75 (735) | |
| Peak Velocity m/sec (in/sec) | 1.6 (63) | 1.6 (63) | 1.7 (67) | |
| Pk-Pk Displacement mm (in) | 38 (1.5) | 38 (1.5) | 38 (1.5) | |
| Armature Resonance Hz (±5%) | 3250 | 3250 | 2750 | |
| Useful Frequency Range Hz | DC-3500 | DC-3500 | DC-3200 | |
| Max. Static Payload Capacity kg (lb) | 150 (330) | 150 (330) | 250 (550) | |
| Pneumatic Internal Load Support | Provided | Provided | Provided | |
| Power Amplifier Specifications | PE4K | PE6K | PE10K | |
| Armature Power Supply | 60V/70A | 80V/80A | 85V/120A | |
| Field Power Supply | Built-in | Built-in | Built-in | |
| Input Impedance | 10 kΩ | 10 kΩ | 10 kΩ | |
| Input Sensitivity | 4 Vrms | 4 Vrms | 4 Vrms | |
| Signal to Noise Ratio (SNR) | >80dB | >80dB | >80dB | |
| Total Harmonic Distortion on resistive load | 0.5%, typical | 0.5%, typical | 0.5%, typical | |
| Sine Oscillator (1–5000 Hz) | Built-in | Built-in | Built-in | |
| Modulation Range | DC-10 KHz | DC-10 KHz | DC-10 KHz | |
| Coupling (to shaker) | Direct | Direct | Direct | |
| Output Efficiency (%) | >90 | >90 | >90 | |
| Structure | Desktop, rack mounted | Modular, rack mounted | Modular, rack mounted | |
| Safety Interlocks | Mains Over/under Voltage, Temperature PA, Temperature Shaker, Over Travel, Cooling Interlock, Phase Fail, Field Fail, Over Load, Auxiliary | |||
| Above specifications are standard specifications, subject to revision due to continuous improvement/ developmental activities without notice. However, | ||||
| the specifications quoted by us in a proposal always supersede the printed/ published specifications. | ||||
| Customized testing solutions and specifications are provided on demand. | ||||
Vibration Test System 2000-3500
| Technical Specification | Model | |||
|---|---|---|---|---|
| PE300 | PE300 | PE360 | PE360 | |
| Sine Force KgF (lbf) | 2000 (4400) | 2500 (5500) | 3000 (6600) | 3500 (7700) |
| Random Force KgF (lbf) | 2000 (4400) | 2500 (5500) | 3000 (6600) | 3500 (7700) |
| Shock Force KgF (lbf) | 4000 (8800) | 5000 (11000) | 6000 (13200) | 7000 (15400) |
| Armature Diameter mm (in) | 300 (11.8) | 300 (11.8) | 360 (14.2) | 360 (14.2) |
| Peak Acceleration g (m/sec2) | 80 (784) | 100(980) | 80 (784) | 100(980) |
| Peak Velocity m/sec (in/sec) | 1.8 (71) | 1.8 (71) | 1.8 (71) | 1.8 (71) |
| Pk-Pk Displacement mm (in) | 51 (2) | 51 (2) | 51/63 (2/2.5) | 51/63/76 (2/2.5/3) |
| Armature Resonance Hz (±5%) | 2650 | 2650 | 2550 | 2550 |
| Useful Frequency Range Hz | DC-3000 | DC-3000 | DC-2800 | DC-2800 |
| Max. Static Payload Capacity kg (lb) | 320 (704) | 320 (704) | 360 (792) | 360 (792) |
| Pneumatic Internal Load Support | Provided | Provided | Provided | |
| Armature Auto Centering | Provided | Provided | Provided | |
| Power Amplifier Specifications | PE24K | PE32K | PE40K | PE44K |
| Armature Power Supply | 115V/ 210A | 135V/240A | 150V/270A | 150V/295 |
| Field Power Supply | Built-in | Built-in | Built-in | Built-in |
| Input Impedance | 10 kΩ | 10 kΩ | 10 kΩ | 10 kΩ |
| Input Sensitivity | 4 Vrms | 4 Vrms | 4 Vrms | 4 Vrms |
| Signal to Noise Ratio (SNR) | >80dB | >80dB | >80dB | >80dB |
| Total Harmonic Distortion on resistive load | 0.5%, typical | 0.5%, typical | 0.5%, typical | 0.5%, typical |
| Sine Oscillator (1–5000 Hz) | Built-in | Built-in | Built-in | Built-in |
| Modulation Range | DC-10 KHz | DC-10 KHz | DC-10 KHz | DC-10 KHz |
| Coupling (to shaker) | Direct | Direct | Direct | Direct |
| Output Efficiency (%) | >90 | >90 | >90 | >90 |
| Structure | Desktop, rack mounted | Modular, rack mounted | Modular, rack mounted | Modular, rack mounted |
| Safety Interlocks | Mains Over/under Voltage, Temperature PA, Temperature Shaker, Over Travel, Cooling Interlock, Phase Fail, Field Fail, Over Load, Auxiliary | |||
| Above specifications are standard specifications, subject to revision due to continuous improvement/ developmental activities without notice. However, | ||||
| the specifications quoted by us in a proposal always supersede the printed/ published specifications. | ||||
| Customized testing solutions and specifications are provided on demand. | ||||
Vibration Test System 4000-6000 Kgf
| Technical Specification | Model | ||
|---|---|---|---|
| PE440 | PE440 | PE440 | |
| Sine Force KgF (lbf) | 4000 (8800) | 5000 (11000) | 50 lts to 8000 lts |
| Random Force KgF (lbf) | 4000 (8800) | 5000 (11000) | 50 lts to 8000 lts |
| Shock Force KgF (lbf) | 8000 (17600) | 10000 (22000) | 50 lts to 8000 lts |
| Armature Diameter mm (in) | 440 (17.3) | 440 (17.3) | 50 lts to 8000 lts |
| Peak Acceleration g (m/sec2) | 85 (833) | 100 (980) | 50 lts to 8000 lts |
| Peak Velocity m/sec (in/sec) | 1.8 (71) | 1.8 (71) | 50 lts to 8000 lts |
| Pk-Pk Displacement mm (in) | 51/63/76 (2/2.5/3) | 51/63/76 (2/2.5/3) | 50 lts to 8000 lts |
| Armature Resonance Hz (±5%) | 2150 | 2150 | 2150 |
| Useful Frequency Range Hz | DC-2350 | DC-2250 | DC-2100 |
| Max. Static Payload Capacity kg (lb) | 600 (1320) | 600 (1320) | 600 (1320) |
| Pneumatic Internal Load Support | Provided | Provided | Provided |
| Armature Auto Centering | Provided | Provided | Provided |
| Power Amplifier Specifications | PE45 | PE56 | PE64 |
| Armature Power Supply | 140V/360A | 140V/410A | 140V/460A |
| Field Power Supply | Built-in | Built-in | Built-in |
| Input Impedance | 10 kΩ | 10 kΩ | 10 kΩ |
| Input Sensitivity | 4 Vrms | 4 Vrms | 4 Vrms |
| Signal to Noise Ratio (SNR) | >80dB | >80dB | >80dB |
| Total Harmonic Distortion on resistive load | 0.5%, typical | 0.5%, typical | 0.5%, typical |
| Sine Oscillator (1–5000 Hz) | Built-in | Built-in | Built-in |
| Modulation Range | DC-10 KHz | DC-10 KHz | DC-10 KHz |
| Coupling (to shaker) | Direct | Direct | Direct |
| Output Efficiency (%) | >90 | >90 | >90 |
| Structure | Desktop, rack mounted | Modular, rack mounted | Modular, rack mounted |
| Safety Interlocks | Mains Over/under Voltage, Temperature PA, Temperature Shaker, Over Travel, Cooling Interlock, Phase Fail, Field Fail, Over Load, Auxiliary | ||
| Above specifications are standard specifications, subject to revision due to continuous improvement/ developmental activities without notice. However, | |||
| the specifications quoted by us in a proposal always supersede the printed/ published specifications. | |||
| Customized testing solutions and specifications are provided on demand. | |||
We are listed amongst the knowledgeable manufacturers, exporters and suppliers of the Bump Testing Machine based in Roorkey, Uttarakhand. These machines that we offer are used to simulate the bumps or shocks experienced by products or materials being transported on a vehicle or devices that need to operate on a moving vehicle. These machines are made from heavy good quality steel and can be used to conduct tests that meet various international standards such as MIL, ISO ASTM and more.
Details :
Technical Specification
| Technical Specification | Free Fall Type (Pneumatic * Type) | |||
|---|---|---|---|---|
| PEBM-04 | PEBM-06 | PEBM-08 | PEBM-10 | |
| Platform Size (mm) | 400 x 400 | 600 x 600 | 800 x 800 | 1000 x 1000 |
| Payload Capacity (Kg) | 150 | 250 | 500 | 1000 |
| Pulse Acceleration (g) | 2-50 (300*) | 2-50 (300*) | 2-50 (300*) | 2-50 (300*) |
| Pulse Duration (mS) | 42447 | 42447 | 3-18) | 42447 |
| Pulse Shape : | Half-Sine | Half-Sine | Half-Sine | Half-Sine |
| Bump Rate (Bumps/sec) | 42372 | 42372 | 42372 | 42372 |
| Drop Height (mm) | 50 (300*) | 50 (300*) | 50 (300*) | 50 (300*) |
| Machine Weight (Kg) | 1800 | 2300 | 2800 | 3200 |
| Machine Dimension (mm) | 1200x1200x1000 | 1500x1500x1000 | 1500x1500x1000 | 1600x1600x1000 |
| Utilities to be provided | Dry filter air 6-8 bar, Power supply 415VAC±10%, 3-phase, 50/60 Hz | |||
| Pneumatic Internal Load Support | Mains Input Over & Under Voltage, Phase fail, Operator safety during pad changes | |||