The company is one of the major Manufacturers and Suppliers of Sensor Gas Chromatograph in Mumbai. The Sensor Gas Chromatograph or SGC, offered by the company, makes use of the short columns and gas sensors to provide quick gas separation as well as super gas sensitivity. The Sensor Gas Chromatograph comes with standard software that can display the results promptly on the attached computers through chromatography charts and gas concentration display. As an optional feature the continuous measurement display is also available.
Highlights of Sensor Gas Chromatograph
Applications Of Sensor Gas Chromatograph
Customization Options For Sensor Gas Chromatograph
Features and Cost â Best Mix
Technical Data
Gases | LPG / Propane CNG / Methane / LNG / PNG Hydrogen Carbon monoxide |
---|---|
Alarm Set-point |
|
Audio Buzzer | 80 dB |
Relay Contact Rating | 1A @ 230V AC/24VDC |
Power | Univ. AC - 100-260VAC , 50-60 Hz |
Controls & Indications | ACK, RST, Battery In/Out |
Battery back-up (optional) | upto 4 hours |
Env. Range | 0 to 50oC, 0 to 95% Rh |
Ordering Details
Monitor Channels | 2 / 4 / 6 / >6 |
---|---|
Detector Units | Diffusion/Suction - FLP / NFLP Blind / 1 Alarm / Full Status |
Local Relay | Yes / No |
Buzzer/Flasher | Yes / No |
Local / Remote Sensor Head | (only for NFLP versions) |
We are one of the leading Mnaufacturers and Suppliers of Gas Leak Alarm Detectors in Mumbai. The Gas Leak Alarm Detectors, offered by us, are detectors with an in-built display and alarm system. The KD-12 Series Gas Leak Alarm Detectors are known for their efficient performance and the numerous features of the product make it widely demanded.
Highlights Of Gas Leak Alarm Detector
Approvals For Gas Leak Alarm Detector
Features Of Gas Leak Alarm Detector
Detects Gases From PPM To VOL% With
We are one of the leading Manufacturers and Suppliers of Toxic Gas Transmitters in Mumbai. Toxic Gas Transmitter 1000D is a series of direct use sensor-transmitter combination units housed in weatherproof (IP65) enclosures. Alternately, Toxic Gas Transmitter is also available in FLP version suitable for hazardous areas (IIA/IIB). Toxic Gas Transmitters are designed for standard two wire operation where the output is supplied via the same wire pair as the power supply. The external circuit loop is connected to the Toxic Gas Transmitter through a screw terminal connector. The units are supplied pre-calibrated for the specified range, and the sensitivity of the device should not drift by more than 2% of full signal per month. Some sensors have cross interference effect of other gases. It is important to specify air composition to help choose appropriate sensor for the Toxic Gas Transmitter.
Features Of Toxic Gas Transmitter
Optional Enhancements For Toxic Gas Transmitter
Highlights
Connections To Controller
Specifications
Operating Voltage | 15-30VDC |
---|---|
Operating Temperature | 0 - 50 deg C |
Power consumption | < 2 W |
Cable entry | Cable diameter : 7 - 9 mm |
Indications | 3 digit LED display |
Enclosure | ABS, IP65 with transparent lid |
Colour of box | Light Gray similar to RAL 7035 |
Size (H x L x D)mm | 80 x120 x 85 |
Weight | < 1 Kg |
Mounting | Wall |
Resolution | 0.1% |
Output linearity | Linear over full range |
Calibration | Via Zero & Span pots |
Expexcted Optg life | 2 yrs. |
Gases | Range (ppm) |
---|---|
CO | 2000, 5000, 10000 |
H2S | 20,50,100 |
SO2 | 20,2000 |
NO2 | 20 |
NO | 250,5000 |
Cl2 | 20 |
EtO | 100 |
PH3 | 10 |
HCN | 100 |
O2 | 25%v/v |
The company is one of the leading Manufacturers and Suppliers of Odour Gas Chromatographs in Mumbai. The Odour Gas Chromatograph measures the volatile sulfide components or VSC in the breath and separate into halitosis components which are hydrogen sulfide, methyl mercaptans, and dimethyl sulfide. Known for their excellent quality and highly precise functioning, the Odour Gas Chromatograph is widely in demand. The Odour Gas Chromatograph is widely used in the breath odor diagnostics treatment. The Odour Gas Chromatograph also has a sophisticated graphical data management software that provides measurement of halitosis strength levels as well as the history of the patients.
Breath Sampling Procedure
The placement pattern of the Odour Gas Chromatograph is flexible enough to eliminate any worries regarding permanent installation. The following steps explain the breath sampling process :