Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Online Gas Detection System (V- 810), Voltage : 12-18VDC, 18-24VDC, Power : 100-200W, 200-400W, 400-800W

Listing ID #1456628

  • TypeGas Detection Systems
  • MaterialAluminium
  • ColorSilver
  • Voltage12-18VDC, 18-24VDC
  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : India only
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • GST No. 27AAACP5821D1ZQ

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Type Gas Detection Systems
  • Material Aluminium
  • Color Silver
  • Voltage 12-18VDC, 18-24VDC
  • Finishing Polished
  • Power 100-200W, 200-400W, 400-800W
  • Feature Durable, Hard Structure, Industry Proven Design
  • Coverage Area 0-2ft, 2-4ft, 4-8ft

This system has a wall mount case incorporating indicator units and an alarm unit of the V Series/V2 Series


Outline

  • V-810 gas detector is compact system of well(panel) mount type with combines indicator units, an alarm unit, and various gas detector heads of the V series
  • Detectors combustible gases, toxic semiconductor manufacturing gases, and oxygen(oxygen deficiency) and gives an alarm signal when the gas concentration goes over a set value (or under a set value for oxygen deficiency), so as to prevent disasters such as gas explosion, poisoning and oxygen deficiency
  • VB- 810 incorporates a backup power supply unit


Features

  • Compact design.
  • Standard cases for 3/6/9/12/15/18/21 points are available
  • Wide variety of input power sources
  • Can be equipped with a Zener barrier
  • 2-stage alarm is also available
  • Combination of the V series/V2 series unit allow detection of and alarm for various gases


Specification

Item / Model V-810
Gas Detected and Detection Range As per specification
Gas Concentration Indication LCD bar-graph level meter
Alarm Set Volume Adjustable within the detection range(Except hexane for which 0.5ml is the alarm set value)
Alarm Accuracy Combustible gas:+25% of an alarm Set Value Toxic gas: +30% of an Alarm Set Value Oxygen: +1.0vol% of an Alarm Set Value(Conforms to JIS T 820)
Alarm Indication
  • Gas Leakage Alarm
  • Trouble Alarm
Indicator Unit
  • Alarm lamp(red) flashes* (Lights up after Reset)
  • Power lamp (green) goes out (Automatic recovery)
Alarm unit
  • Lights up red and buzzer sounds intermittently on alarm from at least one indicator unit (Buzzer stops after Reset)
  • Lights up red and buzzer sounds continuously on trouble at least one indicator unit (Buzzer stops after Reset)
*Self -holding type is standard for the alarm indicator of the indicator units and the alarm units. (Automatic recovery type is also available.)
Contact Output Indicator unit (individual alarm): 1st stage(1a), 2nd stage(1a), 1 A@ 100V Ac (resistance load)
Alarm unit (collective alarm): Alarm 1(1c), Alarm 2(1c),1A@100V AC (resistance load), Trouble (1a), Buzzer (1a)
External Output *1 4-20mA, 0-10mV,1-5V (option), RS-232C output (option)
Operating Temperature Range -10oC to 40oC
Power Source 100-110V AC+10%, 200/220V AC+10%, 24V DC+10%
Power Consumption Diffusion type: (25+5n)VA, suction type: (25+10n)VA (n is the number of detection points)
Others
  • green lamp flashes for 30 s upon energization
  • Alarm delay (option)
  • Linearization (option)
  • Loe flow alarm (option for V2 series)

*1 V2 series are not capable of 0-10mV output.



Download Detail File : Click Here
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Online Gas Detection System (V- 810)?

Quantity
Seller Contact Details
  • Seller Prism Gas Detection Pvt. Ltd.
  • Address Goregaon West, Mumbai, Maharashtra

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Online Gas Detection System (V- 810), Voltage : 12-18VDC, 18-24VDC, Power : 100-200W, 200-400W, 400-800W at Best Price in Mumbai
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Online Gas Detection System (V- 810), Voltage : 12-18VDC, 18-24VDC, Power : 100-200W, 200-400W, 400-800W

Listing ID #1456628

  • TypeGas Detection Systems
  • MaterialAluminium
  • ColorSilver
  • Voltage12-18VDC, 18-24VDC
  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : India only
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • GST No. 27AAACP5821D1ZQ

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Type Gas Detection Systems
  • Material Aluminium
  • Color Silver
  • Voltage 12-18VDC, 18-24VDC
  • Finishing Polished
  • Power 100-200W, 200-400W, 400-800W
  • Feature Durable, Hard Structure, Industry Proven Design
  • Coverage Area 0-2ft, 2-4ft, 4-8ft

This system has a wall mount case incorporating indicator units and an alarm unit of the V Series/V2 Series


Outline

  • V-810 gas detector is compact system of well(panel) mount type with combines indicator units, an alarm unit, and various gas detector heads of the V series
  • Detectors combustible gases, toxic semiconductor manufacturing gases, and oxygen(oxygen deficiency) and gives an alarm signal when the gas concentration goes over a set value (or under a set value for oxygen deficiency), so as to prevent disasters such as gas explosion, poisoning and oxygen deficiency
  • VB- 810 incorporates a backup power supply unit


Features

  • Compact design.
  • Standard cases for 3/6/9/12/15/18/21 points are available
  • Wide variety of input power sources
  • Can be equipped with a Zener barrier
  • 2-stage alarm is also available
  • Combination of the V series/V2 series unit allow detection of and alarm for various gases


Specification

Item / Model V-810
Gas Detected and Detection Range As per specification
Gas Concentration Indication LCD bar-graph level meter
Alarm Set Volume Adjustable within the detection range(Except hexane for which 0.5ml is the alarm set value)
Alarm Accuracy Combustible gas:+25% of an alarm Set Value Toxic gas: +30% of an Alarm Set Value Oxygen: +1.0vol% of an Alarm Set Value(Conforms to JIS T 820)
Alarm Indication
  • Gas Leakage Alarm
  • Trouble Alarm
Indicator Unit
  • Alarm lamp(red) flashes* (Lights up after Reset)
  • Power lamp (green) goes out (Automatic recovery)
Alarm unit
  • Lights up red and buzzer sounds intermittently on alarm from at least one indicator unit (Buzzer stops after Reset)
  • Lights up red and buzzer sounds continuously on trouble at least one indicator unit (Buzzer stops after Reset)
*Self -holding type is standard for the alarm indicator of the indicator units and the alarm units. (Automatic recovery type is also available.)
Contact Output Indicator unit (individual alarm): 1st stage(1a), 2nd stage(1a), 1 A@ 100V Ac (resistance load)
Alarm unit (collective alarm): Alarm 1(1c), Alarm 2(1c),1A@100V AC (resistance load), Trouble (1a), Buzzer (1a)
External Output *1 4-20mA, 0-10mV,1-5V (option), RS-232C output (option)
Operating Temperature Range -10oC to 40oC
Power Source 100-110V AC+10%, 200/220V AC+10%, 24V DC+10%
Power Consumption Diffusion type: (25+5n)VA, suction type: (25+10n)VA (n is the number of detection points)
Others
  • green lamp flashes for 30 s upon energization
  • Alarm delay (option)
  • Linearization (option)
  • Loe flow alarm (option for V2 series)

*1 V2 series are not capable of 0-10mV output.



Download Detail File : Click Here
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Online Gas Detection System (V- 810)?

Quantity
Seller Contact Details
  • Seller Prism Gas Detection Pvt. Ltd.
  • Address Goregaon West, Mumbai, Maharashtra

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice