Listing ID #1972425
Company Information
Ask for more detail from the seller
Contact SupplierDetermined to present the utmost quality, we are involved in offering ECG Machine. Our capable staff keeps manufacturing process under stringent guidance to make certain our quality is in fulfillment with different quality grades set by industry. Hence, our customers can be certain of the excellence on offer. We offer a range of several designs and sizes. At their ease, customers can get it delivered.
General | Power Supply | - | - | - |
---|---|---|---|---|
Power Supply Range | AC 230 V ± 10% | - | - | |
Power Consumption | Less than 12 W, | - | - | |
Battery | Rechargeable NiMH 9.6 V, 1500 mAH battery (Built-in) | - | - | |
Battery Capacity | 3 Hour In Single Channel mode (With A Fully Charged Battery 200 Complete. ECGs are possible in Auto mode with single channel Print format) | - | - | |
- | - | - | - | |
Battery Charging Indicator | Yes | - | - | |
Battery Low Indicator | Yes | - | - | |
Recharging time | Approximately 14 Hours for 100% charging | - | - | |
Mains Protaction | Fuse: T 0.1 A | - | - | |
Internal Power Supply | Fuse-miniature, 4A, Time-lag, T-Protection | - | - | |
Battery Protection | Polymer resettable fuse | - | - | |
Environmental | - | - | - | |
Operating Temperature | 10 to 40 deg. C | - | - | |
Relative Humidity | 25 to 90 % non condensing | - | - | |
Standards | - | - | - | |
Safety Standard | Compliance to Class ii type CF, IEC 60601-1, IEC 60601-2-25 | - | - | |
EMC | IEC 60601-1-2 | - | - | |
Others | - | - | - | |
Dimension | 270 (L) x 180 (H) x 60 (D) mm | - | - | |
Weight | <1.5 Kgs | - | - | |
ECG | ECG Acquisition | 10 Bits; 500 sample / sec | - | - |
ECG Leads | Standard 12 leads; Acquired 8 leads; Reconstructed 4 leads (iii,aVR, aVl, aVF) with lead Indicator | - | - | |
Recording Sensitivity | Manual mode: 2.5-5-10-20 mm/mv ± 5%, Auto mode: Dependent on signal strength, optimises automatically to 2.5-5-10-20mm/mv ± | - | - | |
Filter | Main Interface / Miscle Filter- Linear phase digital 50 Hz Notch filter with, linear Phase selectable, 25 or 35 Hz – 3 dB response, Anti drift filter- Digital 0.5Hz Anti Drift High pass linear Phase filter always inserted and Cannot be Switched off | - | - | |
Signal Memory | 10 Second For each lead in Auto mode | - | - | |
Operating Modes | Manual- Acquisition and printing in real time, Auto – Simultaneous acquisition | - | - | |
Parameter Calculation | Yes, In Auto mode (Selectable) | - | - | |
Keyboard | Tactile keypad with 9 function key and 25 LED function indicator | - | - | |
Input Dynamic | ± 300 mV @ 0 Hz; ± 5 mV in the pass band | - | - | |
Input Impedance | > 100 Mohms | - | - | |
Frequency Response | 0.5 Hz 150 Hz (-3dB) With mains / Muscle Filter | - | - | |
Time constanr | > 3.2 Seconds | - | - | |
CMRR | > 90 dB @ 50 Hz | - | - | |
DF Protection | Internal | - | - | |
Printer | Recording System | Thermal printer, 8 dots / mm; 48 mm usable print width | - | - |
Thermal Paper | In rolls: Height 50 mm, Length 20 mm, grided | - | - | |
Print Channel | 1 | - | - | |
Paper Transport Speed | 25 or 50 mm /sec. | - | - | |
Standard Accessories | Print Cable | 1 no. | Chest electrode | 6 nos. |
Limb Electrodes | 4 nos. | Gel bottle | 1 nos. | |
Paper Roll | 1 no. | User Manual | 1 no. | |
Battery Charger | 1 no. | - | - |
Note : Due to constant upgradation, specifications & features subject to change without prior notice.
Input Circuit | Defibrillation protection built-in |
---|---|
Lead | Standard 12 leads |
Acquisition Mode | Simultaneous 12 lead acquisition(10s-24s) |
A/D Converter | 24bits |
Sampling Rate | 1000Hz/Ch |
Input Voltage Range | ±5mVp-p |
Time Constant | ≥3.2s |
Frequency response | 0.05Hz-150Hz |
Calibration Voltage | 1mV ±2% |
Sensitivity | 2.5,5,10,20,10/5,AGC(mm/mV) |
Input Impedance | ≥50MΩ |
Input Circuit Current | ≤10nA |
Noise Level | ≤12.5 µ Vp-p |
Patient Leakage Current | <10 µA (220 V-240V) |
Patient auxillary Current | <0.1 µA (DC) |
Filters | EMG filter 25Hz/35Hz/45Hz/OFF Anti-baseline drift 0.05Hz/0.15Hz/0.25Hz/0.32Hz/0.5Hz/0.67Hz Low-pass filter 75Hz/100Hz/150Hz AC filter ON/OFF 50/60Hz |
CMRR | ≥115dB |
Power Supply | 100-240 VAC,50 Hz/60Hz,70 VAC |
Battery | Built-in Reacharcheable li-ion Battery 220 mAh@14.8 for 6 hours general use or 280 copies of continuous ECG printing in auto mode |
Recorder | Thermal Printer |
Print Channels | Manual :3 and 6 Auto :Off,3X4,3X4+1R, 6X2,6X2+1R,6X2 Adjust Rhythm : Single Lead and three lead |
Recording paper | 110 mm x140 mm x 144P (Z fold) |
Recording speed | 5 mm/s,6.25 mm/s,10 mm/s,12.5mm/s,25mm/s,50mm/s(±3%) |
Weight | Approximately 2.6 kG(Excluding battery and ECG Paper) |
Dimensions | 322 mm x 310 mm x 101 mm |
Display | 3.5 inch LCD,192 x 64 dots |
External Input | 100 KΩ,sensitivity 10 mm/V±5% |
External Output | 100 KΩ,sensitivity 1V/mV±5% |
Communication ports | Ethernet and RS 232 |
Note : Due to constant upgradation, specifications & features subject to change without prior notice.