20 TR AIR COOLED SCROLL TYPE WATER CHILLER
| 1 | Unit Identification Model | FMACS-20TR-407 |
| 2 | Rated Cooling Duty | 20 TR (Nominal Refrigeration Capacity) |
| 3 | Refrigeration Circuit Configuration | Single, Fully Independent Refrigeration Circuit |
| 4 | Electrical Input Supply | 400 V ±10%, 50 Hz, Three Phase AC System |
| 5 | Electrical Power Consumption | 13.32 kW / 24.9 A |
| 6 | Applied Refrigerant | R-407C, Environmentally Acceptable Refrigerant |
| 7 | Refrigerant Control Mechanism | Thermostatic Expansion Valve Assembly (TXV) |
| 8 | Evaporator Design Saturation Temperature | +5 °C |
| 9 | Condenser Design Saturation Temperature | +35 °C |
| 10 | Permissible Maximum Ambient Temperature | 45 °C |
| 11 | Chilled Water Temperature Operating Window | +7 °C to +10 °C |
| 12 | Chilled Water Flow Capacity Requirement | 12,000 LPH at 5 °C ΔT |
| 13 | Compressor Configuration | Fully Sealed Hermetic Scroll Type Compressor |
| 14 | Compressor Quantity Installed | One (1) Number |
| 15 | Compressor Motor Power Input | 12 kW / 23 Amps |
| 16 | Compressor Starting Arrangement | Direct-On-Line (DOL) Electrical Starting |
| 17 | Capacity Regulation Strategy | Stepwise Capacity Modulation – 0%, 50%, 100% |
| 18 | Evaporator Heat Exchange Arrangement | Shell and Tube Type Water Chilling Evaporator |
| 19 | Evaporator Water Connection Interface | 3 Inch Flanged Type Connections |
| 20 | Evaporator Shell Material of Fabrication | Carbon Steel with Protective Anti-Corrosion Coating |
| 21 | Evaporator Tube Material of Construction | Internally Enhanced Grooved Copper Tubing |
| 22 | Condenser Heat Exchange Arrangement | Shell and Tube Type Condenser Unit |
| 23 | Condenser Tube & Shell Materials | Copper Tubes with Carbon Steel Shell Construction |
| 24 | Chilled Water Pump Configuration | SS-304 Stainless Steel Pump with 1.5 HP Motor |
| 25 | Incorporated Safety & Protection Systems | Compressor Thermal Protection, Electrical Overload Safeguard, High/Low Pressure Safety Devices, Phase Sequence & Phase Loss Protection, Discharge Gas Temperature Cut-out, Water Flow Safety Interlock, Anti-Freeze Safeguard |
| 26 | Electrical Control & Protection Assembly | Microprocessor-Based Control Panel with Protection Relays, Power Contactors, MCBs, Phase Preventer and Time-Delay Relays |
| 27 | Overall Machine Dimensions (L × W × H) | To be advised after order confirmation |
| 28 | Estimated Unit Operating Weight | To be finalized during detailed engineering stage |