Company Information
Ask for more detail from the seller
Contact SupplierTECHNICAL SPECIFICATION
20 TR AIR COOLED SCROLL TYPE WATER CHILLER
| 1 | Chiller Model Reference | FMACS-20TR-407 |
| 2 | Rated Refrigeration Capacity | 20 TR (Cooling Capacity at Standard Conditions) |
| 3 | Refrigeration Circuit Arrangement | Single Dedicated and Independent Refrigeration Circuit |
| 4 | Electrical Power Supply Details | 400 Volts ±10%, 50 Hertz, Three Phase AC |
| 5 | Total Power Input Requirement | 13.32 kW / 24.9 Amps |
| 6 | Refrigerant Employed | R-407C (Eco-Friendly / Environment-Compliant Refrigerant) |
| 7 | Refrigerant Expansion & Control Device | Thermostatic Expansion Valve (TXV Assembly) |
| 8 | Evaporator Design Operating Temperature | +5 °C (Saturation Temperature) |
| 9 | Condenser Design Operating Temperature | +35 °C (Saturation Temperature) |
| 10 | Maximum Design Ambient Temperature Limit | 45 °C |
| 11 | Chilled Water Temperature Control Range | +7 °C to +10 °C |
| 12 | Specified Chilled Water Flow Quantity | 12,000 Liters per Hour at ΔT 5 °C |
| 13 | Compressor Type & Construction | Hermetically Sealed Scroll Compressor |
| 14 | Installed Compressor Quantity | One (01) Unit |
| 15 | Compressor Motor Electrical Input | 12 kW / 23 A |
| 16 | Compressor Starting Arrangement Type | Direct-On-Line (DOL) Starter |
| 17 | Cooling Capacity Control Logic | Stepwise Capacity Modulation – 0%, 50%, 100% |
| 18 | Evaporator Heat Transfer Construction | Shell and Tube Type Chilled Water Evaporator |
| 19 | Evaporator Water Side Connections | 3 Inch Flanged Inlet & Outlet |
| 20 | Evaporator Shell Material Specification | Carbon Steel with Protective Anti-Corrosion Powder Coating |
| 21 | Evaporator Tube Material Specification | Internally Enhanced / Grooved Copper Tubes |
| 22 | Condenser Heat Transfer Construction | Shell and Tube Type Condenser |
| 23 | Condenser Tube & Shell Material Specification | Copper Tubes with Carbon Steel Shell |
| 24 | Chilled Water Circulation Pump Details | Stainless Steel (SS-304) Pump with 1.5 HP Motor |
| 25 | Integrated Safety & Protection Features | Compressor Thermal Protection, Electrical Overload Protection, High & Low Pressure Safety Cut-outs, Phase Sequence and Phase Failure Protection, Discharge Gas Temperature Protection, Water Flow Safety Interlock, Anti-Freeze Protection System |
| 26 | Electrical Control & Protection Panel Description | Microprocessor-Based Control Panel comprising Protection Relays, Power Contactors, MCBs, Phase Preventer Relay and Time-Delay Relays |
| 27 | Overall Equipment Dimensions (L × W × H) | To be furnished after receipt of confirmed purchase order |
| 28 | Approximate Operating / Running Weight | To be confirmed during detailed engineering stage |