Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Insulation Monitor, For College, Home, Hospital, Office, School, Voltage : 220V, 240V

    • Frequency50HZ
    • Screen Size10inch, 14inch, 16inch
    • Memory Size16gb, 8gb
    • ApplicationCollege, Home, Hospital, Office, School
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Retailer
    • Year of Establishment 1997

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Number Of FlowerMonitors
    • ApplicationCollege, Home, Hospital, Office, School
    • Country of Origin220V, 240V
    • Screen Size10inch, 14inch, 16inch
    • Frequency50HZ
    • Memory Size16gb, 8gb
    • FeatureDurable

    Makin use of our world class facilities and high-tech machinery, we aim to mesmerize our customers by the brilliance on offer. Insulation Monitor on offer is available in a variety of specifications. The raw material used in manufacturing is of first-rate quality. The manufacturing process is conducted out by a team of talented professionals who put their best efforts to make certain they produce nothing short of best possible quality.


    Additional Information
    Unscheduled downtimes of machines and plants mean a considerable cost factor. By early detection of insulation faults DOLD insulation monitors help to prevent failures of electrical equipment and thus ensure a better operating reliability and plant safety.


    They are used both in earthed and also non-earthed systems, but differ in their function principle:

    • In earthed systems (TN systems) DOLD differential-current monitors detect fault current with the principle of differential-current measurement and are mainly used to avoid cost-intensive downtimes and to prevent the risk of fire which is latent in the case of slowly evolving insulation faults.
    • In non-earthed systems (IT systems), the insulation resistance to earth of the system to be monitored is measured. Such systems are secured by insulation monitors the use of them in IT systems is required by law by the norm “Safety of Machinery” DIN EN 60204-1 or DIN VDE 0100-410. Thanks to deliberately kept simple functionality of DOLD’s insulation monitors customers benefit from a considerable cost advantage combined with the high quality standard accustomed from DOLD.


    Advantages

    • At a glance:
      • Save space thanks to compact design
      • Cost-effective and easy-to-use by kept simple functionality
      • Flexible by extended application range of our insulation monitors for systems up to 500V AC and 1000 Hz, i.e. also application for 400V three-phase systems Monitor DC systems up to 280V without auxiliary voltage
      • Improve efficiency: avoid unscheduled downtimes and data losses
      • Improve operational reliability and safety: monitor also at standstill, no interruption of operation in the case of single-phase-to-earth fault
      • Better fire safety: detect slowly evolving insulation faults, minimize accidental arcs as frequent fire cause, split and separately monitor systems in fire- and explosion-prone areas
      • Improve workplace safety: no malfunctions of machinery and systems due to earth faults
      • Save time during maintenance and repair: reduce cost by early detection of insulation faults and well-aimed repair.

       

    Technology

    • All conductors of the feeder to be protected (apart from the protective conductor) are guided through a current transformer.
    • In a faultless system, the sum of all currents is zero. No voltage is induced in the current transformer.
    • If fault current flows via earth, the current difference will cause a current in the current transformer. This is evaluated by electronics.

     

    Applications
    Differential-current and insulation monitors are used for early detection of insulation faults in applications where unscheduled downtimes of machinery would have serious consequences.


    They are used in earthed systems for reasons of efficiency and protection against fire and accidents, but they are required by law in non-earthed systems for the same reasons according to DIN VDE 0100-410 and DIN EN 60204-1. Applications include:

    • Wood working industry: fire prevention
    • Chemical industry: prevent the interruption of chemical production processes
    • Automotive: prevent downtime of entire production lines if one partial area fails
    • Food industry: prevent consequential losses, e.g. failure of a cooling plant
    • Medical: prevent the failure of live-saving facilities
    • Data processing: prevent data loss in computer centers, data processing equipment and systems

     

    Moreover, insulation monitors are used to monitor cut off consumers, which are only needed in certain situations, but must then function without problems, flue gas extraction systems in case of a fire, for example.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Insulation Monitor?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice